delim
Endosulfan I Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Endosulfan I

CAS # 959-98-8


Masse molaire406.9251
FormuleC9H6Cl6O3S
= Sources de données : ChemSpider

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Endosulfan I; α-Endosulfan; α-Thiodan; Endosulfan α


Cromatogrammi applicativi

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
GC Multiresidue Pesticide Standard #2-OCP on Rxi-5ms by GC-MS
7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx-CLPesticides and Rtx-CLPesticides2 Using Hydrogen
GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides
Organochlorine Pesticides US EPA Method 8081 on Rtx-1701
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-35
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides Fast Analysis Conditions on Rtx-CLPesticides & Rtx-CLPesticides2 (dual column analysis)
Recovery of Chlorinated Pesticides from Solvent Extracts Using CarboPrep 90
Comparison: Florisil SPE Cleanup of Blank Extract and EPA 8081 Pesticides Extract on Rtx-CLPesticides2
Florisil SPE Cleanup of EPA 8081 Pesticides on Rtx-CLPesticides2
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
Pesticides in Dietary Supplements (Zoom of GCxGC-TOFMS Contour Plot)
Organochlorine Pesticides, PCBs, and BFRs on Rxi-XLB and Rxi-17Sil MS (GCxGC-ECD)
Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200
Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-50
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-5
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 508 on Rtx-5
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.53 mm ID column set)
Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)
Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)
Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2
Pesticides in QuEChERS Extract of Sweet Potato on Rxi-5Sil MS
Organochlorine Pesticides on Rtx-CLPesticides Columns (0.18 mm ID column set)
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.32 mm ID column set)
Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2
Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides
Organochlorine Pesticide Mix AB #2 Rtx-CLPesticides and Rtx-CLPesticides2 (0.25mm ID column set)