delim
o-Cresol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

O-Cresol

CAS # 95-48-7


Masse molaire108.1378
FormuleC7H8O
Point de fusion31 °C, 304 °K, 88 °F
Point d’ébullition191 °C, 464 °K, 376 °F
Densité1.0465 g cm-3
Solubilité dans l’eau31 g dm-3 (at 40 °C)
log P1.962
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Phenol, 2-methyl-; o-Cresol; o-Hydroxytoluene; o-Methylphenol; o-Methylphenylol; o-Oxytoluene; 1-Hydroxy-2-methylbenzene; 2-Cresol; 2-Hydroxytoluene; 2-Methylphenol; Orthocresol; o-Kresol; Rcra waste number U052; o-Cresylic acid


Cromatogrammi applicativi

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Aromatics Stabilwax
Aromatics Rtx-502.2
Solvent Mixture #3 on Stabilwax
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Peak Shape Comparison of Early Eluting Semivolatiles Using Split (10:1) and Splitless Injection at 80 °C Oven Start Temp.
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS
Cresylic Acids on Stabilwax-DA