delim
n-Butyl benzyl phthalate Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Benzyl butyl phthalate

CAS # 85-68-7


Masse molaire312.3597
FormuleC19H20O4
Point de fusion-35 °C, 238 °K, -31 °F
Point d’ébullition370 °C, 643 °K, 698 °F
Densité1.1 g cm−3
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Benzyl butyl phthalate; Butyl benzyl phthalate; Palatinol BB; Santicizer 160; Sicol; Sicol 160; Unimoll BB; n-Butyl benzyl phthalate; NCI-C54375; BBP; Benzyl n-butyl phthalate; 1-Benzyl 2-butyl phthalate; Phthalic acid, benzyl butyl ester


Cromatogrammi applicativi

Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
EPA and EU Phthalates on Rtx-CLPesticides2
EPA and EU Phthalates on Rtx-50
EPA and EU Phthalates on Rtx-CLPesticides
EPA and EU Phthalates on Rxi-5ms
Phthalates on Rxi-XLB (Extended List)
EPA and EU Phthalates on Rxi-XLB
EPA and EU Phthalates on Rtx-440
Phthalates (50 µg/mL) on Rtx-440 (Extended List, Full Scan Mode)
EPA and EU Phthalates on Rxi-35Sil MS
EPA Method 8061A Phthalates on Rtx-440
Semivolatiles on Rxi-5ms (Split Injection)
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi-5Sil MS by U.S. EPA Method 8270
EPA Method 8060 Phthalate Esters on Rtx-5 (Direct Injection)
Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx-5Sil MS
Phthalate Esters by U.S. EPA Method 606 on MXT-5
Phthalate Esters by U.S. EPA Method 606 on Rtx-5
0.5 ng Semivolatile Organics with Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatiles on Rxi-5ms by EPA Method 525.2
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx-5MS