4,4'-DDD Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Dichlorodiphenyldichloroethane

CAS # 72-54-8


Masse molaire320.0412
FormuleC14H10Cl4
Point de fusion109.5 °C
Point d’ébullition350 °C
Solubilité dans l’eau0.09 mg/L
log P6.02 ([[octanol]]-water)
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

p,p'-TDE; Dichlorodiphenyldichloroethane; Dilene; DDD; ME1700; Rhothane; TDE; 4,4'-DDD; ENT 4,225; NCI-C00475; Rhothane d-3; Rothane; Tetrachlorodiphenylethane; NA 2761; OMS 1078; Rcra waste number U060; p,p-Ddd; Ethane, 1,1-dichloro-2,2-bis(4-chlorophenyl)-; 1,1-Dichloro-2,2-bis(p-chlorophenyl)ethane; Benzene, 1,1'-(2,2-dichloroethylidene)bis[4-chloro-; Ethane, 1,1-dichloro-2,2-bis(p-chlorophenyl)-; p,p'-(Dichlorodiphenyl)dichloroethane; 1,1-Bis(p-Chlorophenyl)-2,2-dichloroethane; 1,1-Bis(4-chlorophenyl)-2,2-dichloroethane; 1,1-Dichloro-2,2-bis(4-chlorophenyl)ethane


Cromatogrammi applicativi

Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
Fast Dual Column Analysis of Organochlorine Pesticides (EPA Method 8081) Using a GC Accelerator Kit and Rtx-CLPesticides and Rtx-CLPesticides2 Column Set
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx-CLPesticides and Rtx-CLPesticides2 Using Hydrogen
GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides
Organochlorine Pesticides US EPA Method 8081 on Rtx-1701
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2 (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx-35
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-440
Organochlorine Pesticides US EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides Fast Analysis Conditions on Rtx-CLPesticides & Rtx-CLPesticides2 (dual column analysis)
Recovery of Chlorinated Pesticides from Solvent Extracts Using CarboPrep 90
Comparison: Florisil SPE Cleanup of Blank Extract and EPA 8081 Pesticides Extract on Rtx-CLPesticides2
Florisil SPE Cleanup of EPA 8081 Pesticides on Rtx-CLPesticides2
Pesticides in Dietary Supplements (Zoom of GCxGC-TOFMS Contour Plot)
Organochlorine Pesticides, PCBs, and BFRs on Rxi-XLB and Rxi-17Sil MS (GCxGC-ECD)
Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200
Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx-CLPesticides2 (dual column w/ Rtx-440)
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-50
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-5
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 508 on Rtx-5
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.53 mm ID column set)
Method 8081B Chlorinated Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides by EPA Method 8081A on Rtx-440 (dual column w/ Rtx-CLPesticides2)
Organochlorine Pesticides by EPA Method 8081B on Rtx-CLPesticides/Rtx-CLPesticides2 (extended list)
Organochlorine Pesticides by EPA 8081A on Rtx-CLPesticides & Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides Columns (0.18 mm ID column set)
Organochlorine Pesticide Mix AB #2 on Rtx-CLPesticides2 and Rtx-CLPesticides (0.32 mm ID column set)
Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2
Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides2
Organochlorine Pesticides on Rtx-CLPesticides
Organochlorine Pesticide Mix AB #2 Rtx-CLPesticides and Rtx-CLPesticides2 (0.25mm ID column set)