1,1,1-Trichloroethane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis
Trova un altro composto:
1,1,1-Trichloroethane CAS # 71-55-6
Masse molaire 133.4042 Formule C2 H3 Cl3 Point de fusion -33 °C, 240 °K, -27 °F Point d’ébullition 74 °C, 347 °K, 165 °F Densité 1.32 g/cm3 Solubilité dans l’eau insoluble in water
Spectre de masse (GC)
m/zSélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer. Survolez les pics pour connaître les valeurs.
Synonymes Ethane, 1,1,1-trichloro-; α-Trichloroethane; Aerothene TT; Chlorotene; Chlorothane NU; Chlorothene; Chlorothene NU; Chlorothene VG; Chlorten; Inhibisol; Methylchloroform; Methyltrichloromethane; Trichloroethane; 1,1,1-Trichloroethane; CH3CCl3; α-T; Chloroethene NU; Chloroform, methyl-; NCI-C04626; Solvent 111; Trichloro-1,1,1-ethane; 1,1,1-Trichloorethaan; 1,1,1-Trichloraethan; 1,1,1-Tricloroetano; CF 2
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
Solvents on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Solvents on Stabilwax
EPA Method 524.2 on Rtx-502.2
Custom Residual Solvent Mix on Rxi-624Sil MS (using conditions from Pro ez GC)
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200
Class 1 Residual Solvents for USP <467> Water-Soluble Articles on Rxi-624Sil MS
Volatiles US EPA Method 624 on Rtx-624
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Residual Solvents Class 1 on Rtx-624
Residual Solvents (Class 1) on Stabilwax (G16)
Halogenated Hydrocarbons on Rt-Alumina BOND/CFC
Residual Solvents Rxi-624Sil MS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301
Residual Solvents (Class 1) for Water-Soluble Articles on Rxi-624Sil MS
Class 1 Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS
Solvents on Rtx-BAC1 & Rtx-BAC2 (headspace analysis)