Acetone Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Acetone

CAS # 67-64-1


Masse molaire58.0791
FormuleC3H6O
Point de fusion-95--93 °C, 178-180 °K, -139--136 °F
Point d’ébullition56-57 °C, 329-330 °K, 133-134 °F
Densité0.791 g cm−3
log P-0.042
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Acetone; 2-Propanone; β-Ketopropane; Dimethyl ketone; Dimethylformaldehyde; Methyl ketone; Propanone; Pyroacetic ether; (CH3)2CO; Dimethylketal; Ketone propane; Ketone, dimethyl-; Acetone oil; Chevron acetone; Rcra waste number U002; Sasetone; propan-2-one; NSC 135802; Aceton; UN 1090; Acétone


Cromatogrammi applicativi

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Impurities in α-Methylstyrene on Rtx-1
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
16-Hr Laboratory Air Sample with radiello 145
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Solvents on DiatoSorb-WHP Packed Column
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Aldehyde-Ketone-DNPH TO-11A Calibration Mix on Raptor C18
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Cannabis Residual Solvents at 50 ppm Cutoff
CARB 1004 Aldehyde/Ketone-DNPH Calibration Standard on Raptor ARC-18
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Solvents on Rtx-1701
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
Alcohols Rtx-5
Alcohols Rtx-Volatiles
Solvents on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
BAC Resolution Control Standard n-P on Rtx-BAC Plus 1 and Plus 2 Column Set
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
BAC Resolution Control Standard t-B on Rtx-BAC Plus 1 and Plus 2 Column Set
Blood Alcohol Analysis on Rtx-BAC Plus 2
Blood Alcohol Analysis on Rtx-BAC Plus 1
Volatile Solvents on Rtx-Wax
Solvents on Rtx-5
Solvents on Stabilwax
Rum on Rtx-1301
Rum on CarboBlack B
Scotch on Rtx-1301
Flavor Volatiles on Rtx-1
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Flavor Volatiles on Stabilwax
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Solvents on HayeSep Q
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
Water and Ethanol in Acetone on Rt-Q-BOND
Solvents on MXT-Q-BOND
Volatile Organics by EPA 8260B on Rtx-VMS
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
Volatile Organics by EPA 8260B on Rtx-VMS
Solvents on Rt-QPLOT
Solvents on Polar Rt-QPLOT
Ketones on Rt-QS-BOND
Mushroom Aroma (Synthetic) on Stabilwax
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.53mm ID columns)
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.32mm ID Columns)
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2