Isopropyl Alcohol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Isopropyl alcohol

CAS # 67-63-0


Masse molaire60.0950
FormuleC3H8O
Point de fusion-89 °C, 184 °K, -128 °F
Point d’ébullition82.5 °C, 356 °K, 181 °F
Densité0.786 g/cm3 (20 °C)
Solubilité dans l’eaumiscible
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Isopropyl Alcohol; 2-Propanol; sec-Propyl Alcohol; Alcojel; Alcosolve 2; Avantin; Avantine; Combi-Schutz; Dimethylcarbinol; Hartosol; Imsol A; Isohol; Isopropanol; Lutosol; Petrohol; Propol; PRO; Takineocol; 1-Methylethyl Alcohol; iso-C3H7OH; 2-Hydroxypropane; Propane, 2-hydroxy-; sec-Propanol; Propan-2-ol; i-Propylalkohol


Cromatogrammi applicativi

TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
Bourbon on Rxi-1301Sil MS
Ethanol and IPA on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
USP <467> Residual Solvents Class 3 MIx A on Rxi-624Sil MS
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Cannabis Residual Solvents at 50 ppm Cutoff
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
Volatile Organics TO-15 Volatiles on Rtx-1
Custom Solvents Mix on Stabilwax-MS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax-MS
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Alcohols Rtx-5
Alcohols Rtx-Volatiles
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
BAC Resolution Control Standard n-P on Rtx-BAC Plus 1 and Plus 2 Column Set
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
BAC Resolution Control Standard t-B on Rtx-BAC Plus 1 and Plus 2 Column Set
Blood Alcohol Analysis on Rtx-BAC Plus 2
Blood Alcohol Analysis on Rtx-BAC Plus 1
Solvents on Rtx-Volatiles
Rum on Rtx-1301
Scotch on Rtx-1301
Flavor Volatiles on Rtx-1
Flavor Volatiles on Stabilwax
Cleaning Solvents on Rtx-Wax
Cleaning Solvents (Glass Cleaner) on Rtx-VMS
Petroleum Oxygenates on Rt-TCEP
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.53mm ID columns)
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.32mm ID Columns)
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Cleaning Solvents on Rtx-VMS
Ethyleneamines on Rtx-5 Amine
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Food Packaging Volatiles on Rtx-5MS

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us