Methyl alcohol Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Methanol

CAS # 67-56-1


Masse molaire32.0419
FormuleCH4O
Point de fusion-97.6 °C, 176 °K, -144 °F
Point d’ébullition64.7 °C, 338 °K, 148 °F
Densité0.7918 g/cm3
log P-0.69
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Methyl Alcohol; Methanol; Carbinol; Methyl hydroxide; Methylol; Monohydroxymethane; Wood alcohol; CH3OH; Colonial spirit; Columbian spirit; Hydroxymethane; Wood naphtha; Alcool methylique; Alcool metilico; Columbian spirits; Metanolo; Methylalkohol; Metylowy alkohol; Pyroxylic spirit; Wood spirit; Rcra waste number U154; Pyro alcohol; Spirit of wood; Bieleski's solution; NSC 85232


Cromatogrammi applicativi

Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber
Residual Solvents #1 on Rxi-624Sil MS
Residual Solvents and Gases on Rxi-624Sil MS via HS-Syringe-GC-FID
Rum on Rxi-1301Sil MS
Bourbon on Rxi-1301Sil MS
Scotch on Rxi-1301Sil MS
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Residual Solvents Class 2 - Mix A (2013 Rev) on Stabilwax (G16)
Solvents on DiatoSorb-WHP Packed Column
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen)
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen/Fast Ramp)
Electronic Cigarette Liquid on Rtx-VMS (Helium)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Electronic Cigarette Liquid on Rtx-VMS (Hydrogen)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
Electronic Cigarette Liquid on Rtx-VMS (GC-MS)
Residual Solvents Class 2 — Mix A on Rxi-624Sil MS (G43) by USP <467>
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-100 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-150 (ASTM D5441)
Impurities in Methyl-t-Butyl Ether (MTBE) on Rtx-DHA-50 (ASTM D5441)
Residual Solvents in Cannabis Concentrates on Rxi-624Sil MS by Headspace–Full Evaporation Technique (HS-FET)
Cannabis Residual Solvents at 50 ppm Cutoff
Substituted Pyridine on Rtx-1701
Substituted Pyridine on Stabilwax
Solvents on Rtx-1701
Petroleum Oxygenates (MTBE) on Rtx-1
Petroleum Oxygenates (ASTM D4815) on TCEP (Micropacked) & Rtx-1
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-WAX (G16)
Alcohols and Acetates on Stabilwax-MS
Organic Volatile Impurities on Rtx-5
Organic Volatile Impurities on Rtx-1301
Aldehydes on Stabilwax
Alcohols Rtx-5
Alcohols Rtx-Volatiles
Alcohols Stabilwax
Solvents on Rtx-1
Stability Overlay: 1st and 40th Injections of Short-Chain Amines in Water on Rtx-Volatile Amine
Short-Chain Amines on Rtx-Volatile Amine
BAC Resolution Control Standard n-P on Rtx-BAC Plus 1 and Plus 2 Column Set
Inhalants on Rtx-BAC Plus 1 and Plus 2 Column Set
BAC Resolution Control Standard t-B on Rtx-BAC Plus 1 and Plus 2 Column Set
Blood Alcohol Analysis on Rtx-BAC Plus 2
Blood Alcohol Analysis on Rtx-BAC Plus 1
Volatile Solvents on Rtx-Wax
Solvents on Rt-QS-BOND
Solvents on Rtx-Volatiles
Solvents on Stabilwax
OVIs by Dynamic Headspace and Gerstel MACH on Rtx-624 (G43) and Rtx-WAX (G16)
E85 Fuel Ethanol by ASTM D5501 on Rtx-DHA-150
Rum on Rtx-1301
Rum on CarboBlack B
Scotch on Rtx-1301
Scotch on CarboBlack B
Flavor Volatiles on Rtx-1
Flavor Volatiles on Stabilwax
Cleaning Solvents on Rtx-Wax
Solvents on HayeSep Q
Competitor Comparison: Class 2 - Mix A Residual Solvents for USP <467> Water-Soluble Articles
Short Chain Amines in Water on Rtx-Volatile Amine
Petroleum Oxygenates on Rt-TCEP
Restek PLOT Column Technology Assures Stable Performance Even After 500 Pressure Cycles
Formaldehyde on Rt-U-BOND
Water and Ethanol in Acetone on Rt-Q-BOND
Solvents on MXT-Q-BOND
MXT-Q-BOND Columns are Highly Stable; Pressure Pulsing does not Create Particles or Alter Retention Times
Residual Solvents Class 2 Mixture A on Rtx-624
Residual Solvents (Class 2 - Mixture A) on Stabilwax (G16)
Solvents on Polar Rt-QPLOT
Residual Solvents Rxi-624Sil MS
Volatile Petroleum Hydrocarbons (VPH) Massachusetts Department of Environmental Protection on Rtx-502.2
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.53mm ID columns)
Blood Alcohol on Rtx-BAC1 & Rtx-BAC2 (0.32mm ID Columns)
Solvent Mixture on Rt-Q-BOND
Organic Volatile Impurities on Rtx-5 (Rtx-G27)
Solvent Mixture on Rt-QS-BOND
Solvent Mixture on Rt-S-BOND
Cleaning Solvents on Rtx-VMS
Abused Inhalants on Rtx-BAC1 & Rtx-BAC2
Residual Solvents (Class 2 - Mixture A) for Water-Soluble Articles on Rxi-624Sil MS
Class 2 - Mix A Residual Solvents for Water-Insoluble Articles on Rxi-624Sil MS

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us