delim
Carbaryl Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Carbaryl

CAS # 63-25-2


Masse molaire201.2212
FormuleC12H11NO2
Point de fusion142 °C, 415 °K, 288 °F
Point d’ébullitiondecomposes before boiling
Densité1.2 g/cm3
Solubilité dans l’eauvery low
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Carbaril; 1-Naphthalenol, methylcarbamate; α-Naphthalenyl methylcarbamate; α-Naphthyl methylcarbamate; α-Naphthyl N-methylcarbamate; Arilat; Arilate; Arylam; Atoxan; Bercema NMC50; Caprolin; Carbatox; Carbatox 75; Carbatox-60; Carbavur; Carpolin; Compound 7744; Denapon; Dicarbam; Dyna-carbyl; Experimental Insecticide 7744; ENT-23969; Gamonil; Germain's; Karbatox


Cromatogrammi applicativi

LC Multiresidue Pesticide Mix Extracted from Celery with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
LC Multiresidue Pesticide Mix Extracted from Brown Rice Flour with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
Carbamate Pesticides on Ultra Carbamate by LC-MS/MS
QuEChERS Performance Standards Kit Pesticides on Rxi-5ms
Comparison of Low-Level Pesticide Responses Using Restek Premium vs. Siltek Inlet Liners, Part I (QuEChERS Performance Standard C on Rxi-5ms)
Comparison of Low-Level Pesticide Responses Using Restek Premium vs. Standard Deactivation Inlet Liners, Part I (QuEChERS Performance Standard C on Rxi-5ms)
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
LC Multiresidue Pesticide Standard #1 on Raptor ARC-18 by LC-MS/MS
GCxGC-TOFMS Analysis of Multi-Pesticide Standard Using Rxi-5Sil MS and Rtx-200
LC Multiresidue Pesticide Standard #1 on Ultra Aqueous C18 by LC-MS/MS
Pesticides (Carbamates) on Ultra Carbamate (Fast LC)
Incurred Pesticides in Red Bell Pepper QuEChERS Extract on Ultra Aqueous C18
GCxGC-TOFMS Chromatogram of QuEChERS Extract of Red Bell Pepper Showing Incurred Pesticides Using Rxi-5Sil MS and Rtx-200
Zoom of Pesticide Standard by GCxGC-TOFMS Using Rxi-5Sil MS and Rtx-200
Marijuana Pesticides by GCxGC on Rxi-5Sil MS and Rtx-200
Pesticides (Carbamates) on Ultra Carbamate
Pesticides on Pinnacle DB Aqueous C18
Carbamates in Orange Oil on Ultra Carbamate
Carbamates on Ultra Carbamate
Pesticides on Ultra Aqueous C18