delim
Triphenylphosphate Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Triphenyl phosphate

CAS # 115-86-6


Masse molaire326.2831
FormuleC18H15O4P
Point de fusion48-50 °C
Point d’ébullition244 °C 10 mm Hg
Densité1.184 g/mL
Solubilité dans l’eauorganic solvents
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Triphenyl phosphate; TPP; Phosphoric acid, triphenyl ester; Celluflex TPP; Disflamoll TP; Phenyl phosphate ((PhO)3PO); Phosflex TPP; Triphenoxyphosphine oxide; TP; Trifenylfosfat; Altal; Dymel; Kronitex TPP; Phenyl phosphate; Triphenyl phosphoric acid ester; NSC 57868; TPhP; Triphénylphosphate; Trifenilfosfato


Cromatogrammi applicativi

EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at 10x the Method Reporting Limit (SIM Analysis)
EPA Method 525.3 UCMR4 Standard on Rxi-5Sil MS at Method Reporting Limit (SIM Analysis)
EPA Method 525.3 Internal and Surrogate Standards on Rxi-5Sil MS
EPA Method 525.3 ONP Calibration Standard (with 525.3 Internal and Surrogate Standards) on the Rxi-5Sil MS
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 PCB Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 OPP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi-5Sil MS
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
Semivolatile Organics in Drinking Water on Rxi-5Sil MS by EPA Method 525.2
EPA Method 8140/8141/8141A Organophosphorus Pesticides on Rtx-35
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1701
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-1
Organophosphorus Pesticides US EPA Method 8140/8141/8141A on Rtx-35
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorus Pesticides (European) on Rtx-CLPesticides
Organophosphorous Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides & Rtx-OPPesticides2
Semivolatiles on Rxi-5ms by EPA Method 525.2
Pesticides and Brominated Flame Retardants by EPA Method 527 on Rxi-5Sil MS
Organophosphorus Pesticides by EPA Method 8140/8141/8141A on Rtx-CLPesticides
Organophosphorus Pesticides by US EPA Method 8140/8141/8141A on Rtx-CLPesticides2
Organophosphorus Pesticides U.S. EPA Method 8141A on Rtx-OPPesticides2

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us