Propylene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Propene

CAS # 115-07-1


Masse molaire42.0797
FormuleC3H6
Point de fusion-185.2 °C, 88 °K, -301 °F
Point d’ébullition-47.6 °C, 226 °K, -54 °F
Densité1.81 kg/m3, gas (1.013 bar, 15 °C)
613.9 kg/m3, liquid
Solubilité dans l’eau0.61 g/m3
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Propene; Propylene; 1-Propene; Methylethylene; 1-Propylene; CH3CH=CH2; Methylethene; NCI-C50077; Pregn-4-ene-3,20-dione, 11,17,21-trihydroxy-,(11β)-; UN 1077; R 1270


Cromatogrammi applicativi

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
Hydrocarbon Gases on Rt-Q-BOND
Refinery Gas on Rt-Q-BOND
4-Hr Shipping Facility Air Sample with radiello 145
16-Hr Laboratory Air Sample with radiello 145
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
Refinery Gas on Rtx-DHA-100 (ASTM D2163)
Refinery Gas on Rt-Alumina BOND/Na2SO4 (ASTM D2163-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
40 mL of Electronic Cigarette Vapor Collected on a Thermal Desorption Tube and Analyzed on Rtx-VMS
PAMS 57 Component Mix on Rtx-1 (105 m)
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
C1-C5 Hydrocarbons on Rt-Alumina BOND/MAPD
Gasoline Light Fractions on Rtx-DHA-150
Light Hydrocarbons on Rtx-DHA-150
Refinery Gas Hydrocarbons on Rt-Alumina BOND/Na2SO4
Propane Camping Fuel on Rt-Alumina BOND/KCl
Refinery Gas on Rt-Alumina BOND/KCl
Refinery Gas
Propylene and C1-C5 Hydrocarbons on Rt-Alumina BOND/Na2SO4
Refinery Gas C1 to C5 Using n-Octane on Res-Sil C Packing
Refinery Gas Using OPN on Res-Sil C Packing
Refinery Gas Calibration Standard on Refinery Gas Packed Column Set
Sulfur Compounds and Hydrocarbons on Rt-XLSulfur
Propane Camping Fuel on Rt-Alumina BOND/Na2SO4
Refinery Gas on MXT-Alumina BOND/Na2SO4
Refinery Gas #6 on Rt-QS-BOND
Refinery Gas Mix on Rt-QS-BOND
Ozone Precursors on Rtx-1
Ethylene and C1-C5 Hydrocarbons by ASTM D6159-97 on Rt-Alumina BOND/KCl, Rtx-1
Refinery Gas on Rt-Alumina BOND (Na2SO4)
Hydrocarbon Gases on HayeSep® S (micropacked)

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us