Dodecane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Dodecane

CAS # 112-40-3


Masse molaire170.3348
FormuleC12H26
Point de fusion-10--9 °C, 263.2-263.8 °K, 14-15 °F
Point d’ébullition214-218 °C, 487-491 °K, 417-424 °F
Densité780.8 mg mL−1
log P6.821
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Dodecane; n-Dodecane; Adakane 12; Ba 51-090453; CH3(CH2)10CH3; Bihexyl; Dihexyl; n-Dodecane min; Duodecane; C12

Prodotti correlati

Name
Standard DHA PiONA
Standard DHA PONA
Miscela precursori di ozono/PAMS
Miscela Massachusetts APH
Miscela di screening VOA 2
Standard tempo di ritenzione del serbatoio di stoccaggio sotterraneo con perdite
Marcatore tempo di ritenzione
Miscela marcatori tempo di ritnzione TNRCC 1005
Miscela DRO (Tennessee/Mississippi)
Standard di calibrazione range DRO/ORO
Miscela di calibrazione ETPH Connecticut
Standard TRPH Florida
Standard idrocarburi alifatici EPH MA
Miscela di controllo frazionamento MA
Standard madre marcatore punto di ebollizione alternativo/distribuzione numero carbonio
Miscela marcatore tempo di ritenzione TNRCC 1006
Standard marcatore VPH WA
Standard VPH WA
Miscela idrocarburi alifatici EPH WA
Miscela di controllo frazionamento EPH WA
Miscela DRO (EPA/Wisconsin)
Miscela di calibrazione D2887
Miscela di calibrazione D3710-95
ASTM D2887-12 Standard di calibrazione
Miscela di controllo risoluzione colonna E1387
Miscela di test E1618
Miscela standard di n-alcani per test prestazioni di sistema
Miscela di test colonna per ammina (GC)
Miscela Atlantic RBCA EPH
Miscela standard di n-alcani per test prestazioni di sistema
Standard TRPH Florida (HC)
Miscela di test colonna chirale
Miscela di test ammina 900
Miscela di test Kovats 3
Oxy Set-Up Blend
Standard di calibrazione composti alifatici NJDEP EPH 10/08 Rev. 2
NJDEP EPH 10/08 Rev. 2 - Miscela di aggiunta in matrice composti alifatici
Miscela di controllo frazionamento composti alifatici NJDEP EPH 10/08 Rev. 2
Miscela di test colonna per ammine volatili
Miscela di test GC-FID
Standard paraffine DHA
Standard qualitativo di Indice del Tempo di Ritenzione

Cromatogrammi applicativi

PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
ASTM D7504: Impurities in Monocyclic Aromatic Hydrocarbons on Stabilwax
Petroleum Hydrocarbons (TPH) on Rxi-1ms
TNRCC 1006 Retention Time Marker Mix on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
MA DEP EPH Aliphatics on Rxi-5Sil MS
NJ DEP EPH Aliphatics on Rxi-5Sil MS
MA DEP EPH Aliphatics on Rxi-5Sil MS by Split Injection
PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline with Oxygenates on MXT-1 (ASTM D7096-16)
Simulated Distillation of Gasoline on MXT-1 (ASTM D7096-16)
Reformate Standard on Rtx-DHA 50 by Optimized ASTM D5134-13
Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887
Detailed Hydrocarbon Analysis (DHA) on Rtx-DHA-100
Diesel #2/Mineral Oil Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
DRO/ORO Calibration Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
DRO/ORO Calibration Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Mineral Oil Standard on Rxi-5HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi-1HT
PAMS 57 Component Mix on Rtx-1 (105 m)
Volatile Amine Test Mix on Rtx-Volatile Amine (60 m x 0.32 mm ID)
Lubricant (Synthetic) on Stabilwax
BTEX on Rtx-502.2
Solvent Mixture #1 on Rtx-1
Solvent Mixture #1 on Rtx-200
Solvent Mixture #1 on Stabilwax
Solvent Mixture #2 on Rtx-1
Solvent Mixture #2 on Rtx-200
Solvent Mixture #2 on Stabilwax
Solvent Mixture #3 on Rtx-1
Solvent Mixture #3 on Rtx-200
Reformate on Rtx-1
Crude Oil, Arabian Light on Rtx-1
Crude Oil, Prudhoe Bay on Rtx-1
Alcohols Stabilwax
Solvent Mixture #3 on Stabilwax
C5-C72 Hydrocarbons on MXT-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT-1HT SimDist by ASTM D6352
Amine Test Mix Rtx-35 Amine
Wisconsin GRO Mix, plus C12 on Rtx-502.2
C10-C40 Alkanes on Rxi-5HT
Low Bleed, High Efficiency MXT-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT-1HT SimDist at 430 °C
n-Alkanes on Rtx-Mineral Oil
Petroleum Oxygenates on Rt-TCEP
Aromatics on Rt-TCEP
Hydrocarbons (C7-C42) on Rtx-1
Mass APH on Rxi-1ms
Simulated Distillation (Standard Calibration) on MXT-1 SimDist
n-alkanes (C10-C40) on Rtx-Mineral Oil
Sim Dist by ASTM D3710 on Rtx-1 SimDist 2887 (calibration)
DRO Mix on Rtx-5
Hydrocarbons (C10-C44) on MXT-1HT SimDist
Simulated Distillation (C5-C44) on Rtx-2887
Detailed Hydrocarbons Analysis Rtx-DHA-100
NJDEP EPH Aliphatic Fraction on Rtx-5
Fast Detailed Hydrocarbons Analysis (DHA) on Rtx-DHA-100/Rtx-5 DHA
Food Packaging Volatiles on Rtx-5MS

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us