1,2-Dibromoethane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis
Trova un altro composto:
1,2-Dibromoethane CAS # 106-93-4
Masse molaire 187.8612 Formule C2 H4 Br2 Point de fusion 9-10 °C, 282.5-283.3 °K, 49-50 °F Point d’ébullition 129-133 °C, 402-406 °K, 264-271 °F Densité 2.18 g mL−1
Spectre de masse (GC)
m/zSélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer. Survolez les pics pour connaître les valeurs.
Synonymes Ethane, 1,2-dibromo-; α,β-Dibromoethane; sym-Dibromoethane; Aadibroom; Bromofume; Dowfume W-8; Dowfume W85; Ethylene bromide; Ethylene dibromide; EDB; Glycol Dibromide; Iscobrome D; Nefis; Sanhyuum; Soilfume; 1,2-Dibromoethane; CH2BrCH2Br; Dibromoethane; Aethylenbromid; Bromuro di etile; Celmide; DBE; 1,2-Dibromaethan; 1,2-Dibromoetano; Dibromure D'ethylene
TO-15 (HJ759) + PAMS on Rt-Alumina BOND/MAPD (by FID) and Rxi-624Sil MS (by MS) using Deans Switch
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (60 m, 40 °C start)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
25 µg/L 8260 MegaMix Revised on Rtx-VMS
40 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi-1ms (60 m)
TO-15 65 Component Mix on Rxi-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx-1
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 1.5 mL/min)
Volatile Organics US EPA Method 8260B on Rtx-VMS
EPA Method 524.2, Revision 4 Rtx-VMS
TO-15 65 Component Mix on Rxi-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi-1ms (30 m)
Organochlorine Pesticides on Rtx-CLPesticides and Rtx-CLPesticides2 by EPA Method 504.1 (Dual Column Analysis)
EPA Method 524.2 on Rtx-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx-502.2
Volatile Organics by EPA 8260B & Oxygenates on Rtx-VMS
Volatiles by EPA Method 8260 on Rxi-624Sil MS (30m, 0.25mm ID, 1.40µm)
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-5
Chlorinated Disinfection Byproducts by US EPA Method 551.1 on Rtx-200
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8260B on Rtx-VMS
Volatile Organics by EPA 8021 on Rtx-VRX
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx-VMS
EDB/DBCP by EPA 504.1 on Rtx-CLPesticides & Rtx-CLPesticides2
Chlorinated Disinfection Byproducts, Chlorinated Solvents, and Halogenated Pesticides by EPA 551.1 on Rtx-1301