Questo cromatogramma potrebbe contenere analiti che sono sinonimi dei vostri parametri di ricerca.
LC Multiresidue Pesticide Mix Extracted from Celery with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
Peaks
tR (min)
Precursor Ion
Product Ion 1
Product Ion 2
1.
Cyromazine
0.749
167.1
68.1
43.1
2.
Methamidophos
1.314
142.0
94.0
125.1
3.
Formetanate
1.684
222.1
165.0
46.1
4.
Carbofuran
1.685
222.2
165.0
123.1
5.
Methabenzthiazuron
1.685
222.0
165.0
150.0
6.
Acephate
1.692
184.0
143.0
49.0
7.
Pymetrozine
1.705
218.1
105.0
78.0
8.
Aminocarb
1.711
209.1
137.1
152.1
9.
Propamocarb
1.731
189.1
102.0
144.1
10.
Omethoate
1.899
214.0
125.0
183.0
11.
Dinotefuran
1.964
203.1
129.1
87.1
12.
Aldicarb sulfoxide
2.005
207.1
89.0
132.1
13.
Butoxycarboxim
2.016
223.0
106.0
166.0
14.
Nitenpyram
2.044
271.0
56.0
56.0
15.
Aldicarb sulfone
2.055
240.2
148.0
86.0
16.
Carbendazim
2.084
192.0
160.0
131.9
17.
Oxamyl
2.150
237.1
72.0
90.0
18.
Flonicamid
2.230
230.1
203.0
148.0
19.
Methomyl
2.258
163.1
88.0
106.1
20.
Thiabendazole
2.273
201.8
104.0
104.0
21.
Thiamethoxam
2.283
292.1
211.1
181.1
22.
Fuberidazole
2.362
185.0
157.1
103.0
23.
Monocrotophos
2.373
224.1
127.0
193.1
24.
Dioxacarb
2.374
224.1
167.0
77.1
25.
Mexacarbate
2.377
223.2
151.1
151.1
26.
Dicrotophos
2.520
238.1
112.1
72.0
27.
Imidacloprid
2.532
256.1
175.0
209.0
28.
Clothianidin
2.541
250.0
169.0
113.0
29.
Dimethoate-d6 (IS)
2.650
236.2
205.2
131.2
30.
Fenuron
2.660
165.0
72.1
46.1
31.
Trichlorfon
2.664
257.0
108.9
220.8
32.
Dimethoate
2.666
230.0
125.0
125.0
33.
3-Hydroxycarbofuran
2.680
238.1
163.0
163.0
34.
Vamidothion
2.693
288.0
146.0
118.0
35.
Mevinphos
2.710
225.1
127.0
127.0
36.
Acetamiprid
2.720
223.0
126.0
56.1
37.
Propoxur
2.765
210.0
111.0
168.0
38.
Ethirimol
2.768
210.2
140.2
98.2
39.
Cymoxanil
2.802
199.1
128.2
111.2
40.
Thiacloprid
2.862
253.0
126.0
99.0
41.
Pirimicarb
2.871
239.2
72.0
182.1
42.
Butocarboxim
2.993
191.2
75.3
41.3
43.
Aldicarb
3.020
208.2
89.2
89.2
44.
Tricyclazole
3.062
190.0
136.0
136.0
45.
Oxadixyl
3.073
279.1
219.1
132.1
46.
Carbetamide
3.078
237.1
118.1
118.1
47.
Simetryn
3.103
214.1
68.0
96.0
48.
Thiophanate-methyl
3.144
343.0
151.0
311.1
49.
Thidiazuron
3.147
221.1
102.1
127.9
50.
Bendiocarb
3.203
224.1
109.0
109.0
51.
Prometon
3.206
226.1
142.1
184.0
52.
Secbumeton
3.210
226.2
100.2
100.2
53.
Imazalil
3.216
297.1
159.0
41.1
54.
Terbumeton
3.217
226.1
114.1
170.1
55.
Metribuzin
3.226
215.1
187.1
131.0
56.
Pyracarbolid
3.274
218.1
125.1
97.0
57.
Tebuthiuron
3.307
229.1
172.1
116.0
58.
Carbaryl
3.309
202.1
145.0
127.0
59.
Carboxin
3.321
236.1
143.0
87.1
60.
Monolinuron
3.371
215.1
126.0
148.0
61.
Fluometuron
3.378
233.1
72.1
46.1
62.
Diuron
3.380
233.1
72.1
46.0
63.
Ethiofencarb
3.400
226.0
107.0
164.0
64.
Ametryn
3.419
228.1
68.1
186.1
65.
Chlorotoluron
3.446
213.0
72.1
46.1
66.
Metobromuron
3.479
259.0
170.0
148.1
67.
Propham
3.496
180.1
77.1
77.1
68.
Flutriafol
3.504
302.0
70.1
123.0
69.
Methoprotryne
3.508
272.1
170.0
198.1
70.
Forchlorfenuron
3.535
248.1
93.0
93.0
71.
Isoprocarb
3.540
194.1
95.1
137.1
72.
Fenpropimorph
3.549
304.2
147.1
117.0
73.
Atrazine-d5 (SS)
3.571
221.2
179.2
101.3
74.
Isocarbophos
3.602
291.1
231.1
121.1
75.
Isoproturon
3.609
207.1
72.1
46.1
76.
Desmedipham
3.616
318.0
154.1
301.0
77.
Phenmedipham
3.617
318.1
108.1
93.1
78.
Spiroxamine
3.622
298.2
144.2
58.2
79.
Pyrimethanil
3.639
200.0
82.0
82.0
80.
Metalaxyl
3.688
280.1
220.1
192.1
81.
Chlorantraniliprole
3.731
484.0
452.8
285.8
82.
Cycluron
3.780
199.1
89.1
46.0
83.
Prometryn
3.798
242.1
158.0
200.2
84.
Linuron-d6 (SS)
3.839
255.1
160.1
185.2
85.
Linuron
3.851
249.0
160.0
182.0
86.
Fenobucarb
3.885
208.0
95.1
152.1
87.
Azoxystrobin
3.914
404.2
372.0
344.0
88.
Diethofencarb
3.924
268.1
226.1
124.0
89.
Fludioxonil*
3.927
247.1
180.1
126.1
90.
Ethofumesate
3.928
304.1
121.1
241.0
91.
Ethiprole
3.936
397.0
255.0
255.0
92.
Methiocarb
3.956
226.1
121.1
121.1
93.
Siduron
3.962
233.3
94.0
137.1
94.
Halofenozide
3.972
331.1
104.9
275.0
95.
Fenamidone
3.986
312.0
92.1
236.1
96.
Furalaxyl
3.989
302.1
95.0
95.0
97.
Acibenzolar-S-methyl
4.018
210.9
136.1
91.1
98.
Nuarimol
4.027
315.1
252.0
207.0
99.
Dimethomorph
4.040
388.2
300.9
165.1
100.
Boscalid
4.048
343.0
306.8
140.0
101.
Mandipropamid
4.065
412.1
328.1
125.0
102.
Flutolanil
4.074
324.1
242.0
242.0
103.
Promecarb
4.092
208.1
109.0
151.0
104.
Triadimenol
4.114
296.1
70.1
43.1
105.
Paclobutrazol
4.115
294.0
70.1
125.0
106.
Mepronil
4.158
270.1
119.0
119.0
107.
Cyproconazole
4.169
292.2
70.1
125.0
108.
Bupirimate
4.186
317.2
166.0
237.1
109.
Myclobutanil
4.192
289.2
70.1
125.1
110.
Chloroxuron
4.220
291.1
72.1
46.1
111.
Methoxyfenozide
4.225
369.2
149.0
313.1
112.
Cyprodinil
4.261
226.1
93.0
77.0
113.
Triadimefon
4.281
294.0
69.0
197.0
114.
Bifenazate
4.291
301.1
170.1
170.1
115.
Mefenacet
4.323
299.1
120.1
120.1
116.
Mepanipyrim
4.329
224.1
106.1
106.1
117.
Fluquinconazole
4.342
376.0
348.9
307.0
118.
Fluoxastrobin
4.376
459.2
427.0
188.1
119.
Tetraconazole
4.379
372.0
159.0
70.0
120.
Fenhexamid
4.382
302.1
97.1
55.1
121.
Bromuconazole isomer 1
4.382
376.0
159.0
159.0
122.
Iprovalicarb
4.408
321.2
119.0
91.1
123.
Butafenacil
4.408
492.1
179.9
179.9
124.
Flufenacet
4.424
364.1
152.0
194.1
125.
Triticonazole
4.427
318.0
70.0
125.0
126.
Cyazofamid
4.431
325.1
108.0
44.0
127.
Diflubenzuron
4.451
311.0
158.0
141.0
128.
Spirotetramat
4.478
374.1
330.1
302.0
129.
Fenarimol
4.509
331.0
267.9
189.1
130.
Fenbuconazole
4.514
337.0
125.0
70.1
131.
Epoxiconazole
4.525
330.0
121.1
101.0
132.
Etaconazole
4.553
328.1
159.0
55.0
133.
Fipronil*
4.573
436.9
332.0
252.0
134.
Neburon
4.634
275.0
88.1
88.1
135.
Flusilazole
4.640
316.1
165.1
165.1
136.
Fenoxycarb
4.647
302.2
88.1
116.1
137.
Picoxystrobin
4.671
368.0
145.0
205.0
138.
Rotenone
4.679
395.1
213.1
192.1
139.
Tebufenozide
4.715
353.2
133.1
105.0
140.
Dimoxystrobin
4.732
327.1
116.1
116.1
141.
Bromuconazole isomer 2
4.740
378.0
159.0
159.0
142.
Flubendiamide
4.744
700.0
408.0
274.0
143.
Diclobutrazol
4.759
328.0
70.1
159.0
144.
Carfentrazone ethyl
4.768
429.1
412.1
346.1
145.
Kresoxim-methyl
4.796
314.0
116.0
116.0
146.
Tebuconazole
4.821
308.0
70.1
124.9
147.
Spinosad A
4.833
732.5
142.1
98.1
148.
Penconazole
4.848
284.1
70.1
159.0
149.
Zoxamide
4.891
336.1
187.0
159.0
150.
Famoxadone
4.937
392.2
238.0
238.0
151.
Prochloraz
4.954
376.0
308.0
70.1
152.
Diazinon-diethyl-d10 (IS)
4.955
315.2
170.2
154.3
153.
Triflumuron
4.982
359.1
156.0
111.0
154.
Hydramethylnon
4.984
495.2
323.2
45.2
155.
Hexaconazole
4.991
314.1
70.0
158.8
156.
Benalaxyl
5.016
326.2
148.0
208.1
157.
Metconazole
5.030
320.1
70.1
125.0
158.
Propiconazole
5.053
342.0
159.0
69.0
159.
Pyraclostrobin
5.070
388.0
163.1
163.1
160.
Clofentezine
5.075
303.0
138.0
102.0
161.
Bitertanol
5.114
338.2
70.1
70.1
162.
Spinosad D
5.139
746.5
142.0
98.0
163.
Benzoximate
5.169
364.0
105.0
105.0
164.
Diniconazole
5.182
326.1
70.0
158.9
165.
Thiobencarb
5.192
258.0
125.0
89.1
166.
Spinetoram
5.220
748.5
142.1
98.2
167.
Pencycuron
5.225
329.1
125.0
89.0
168.
Triflumizole
5.340
346.1
278.0
73.1
169.
Hexaflumuron*
5.342
459.0
439.0
175.0
170.
Indoxacarb
5.370
528.1
203.0
203.0
171.
Difenoconazole
5.377
406.1
251.1
152.0
172.
Trifloxystrobin
5.419
409.0
186.0
206.0
173.
Ipconazole
5.421
334.2
70.0
124.9
174.
Emamectin-benzoate B1b
5.441
872.2
158.2
82.1
175.
Novaluron*
5.443
491.0
471.0
304.9
176.
Clethodim
5.559
360.1
164.1
268.1
177.
Teflubenzuron
5.610
380.9
140.9
158.0
178.
Buprofezin
5.618
306.2
106.1
86.0
179.
Emamectin-benzoate B1a
5.632
886.5
158.0
82.1
180.
Alanycarb
5.684
400.1
91.0
238.0
181.
Fluazinam*
5.719
463.0
415.9
397.9
182.
Metaflumizone*
5.720
505.1
302.1
328.0
183.
Furathiocarb
5.731
383.1
195.0
252.1
184.
Temephos
5.753
467.1
125.0
418.9
185.
Lufenuron
5.771
511.2
141.0
158.0
186.
Tebufenpyrad
5.775
334.0
117.0
145.0
187.
Pyriproxyfen
5.834
322.0
96.0
227.1
188.
Piperonyl butoxide
5.858
356.2
177.0
119.1
189.
Hexythiazox
5.922
353.2
168.1
168.1
190.
Quinoxyfen
5.924
308.1
197.0
162.0
191.
Flufenoxuron
5.980
489.1
141.0
141.0
192.
Propargite
6.084
368.1
231.1
175.0
193.
Etoxazole
6.090
360.2
141.0
57.1
194.
Spiromesifen
6.124
371.3
273.2
255.2
195.
Chlorfluazuron
6.157
539.8
382.9
158.0
196.
Spirodiclofen
6.263
428.3
71.1
313.1
197.
Fenpyroximate
6.277
422.1
366.1
138.1
198.
Pyridaben
6.433
365.2
147.0
309.1
199.
Eprinomectin
6.463
914.6
186.1
154.1
200.
Abamectin B1a
6.541
890.6
305.4
567.2
201.
Fenazaquin
6.549
307.1
161.0
131.1
202.
Doramectin
6.727
916.6
331.2
593.4
203.
Ivermectin
6.884
892.6
551.4
569.4
*Detected in ESI- mode
LC_FS0522
Column
Raptor ARC-18 (cat.# 9314A12)
Dimensions:
100 mm x 2.1 mm ID
Particle Size:
2.7 µm
Pore Size:
90 Å
Guard Column:
Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9314A0252)
Temp.:
50 °C
Sample
LC multiresidue pesticide kit (cat.# 31971)
Diluent:
Water:acetonitrile 9:1
Conc.:
1 ng/mL see notes for more details
Inj. Vol.:
5 µL
Mobile Phase
A:
0.2% Formic acid, 2 mM ammonium formate in water
B:
0.2% Formic acid, 2 mM ammonium formate in methanol
Time (min)
Flow (mL/min)
%A
%B
0.00
0.4
95
5
2.00
0.4
40
60
4.00
0.4
25
75
6.00
0.4
0
100
7.50
0.4
0
100
7.51
0.4
95
5
9.50
0.4
95
5
Detector
MS/MS
Ion Mode:
ESI+/ESI-
Mode:
Scheduled MRM
Instrument
UHPLC
Notes
Although the ten LC multiresidue pesticides kit mixes are formulated to ensure maximum long-term stability and reliability as packaged, stability may become an issue when a large number of compounds with different chemical functionalities are combined together into a single mix. This should be taken into consideration for quantitative analysis.
Sample Preparation: Celery purchased from a local market was comminuted using a Robot Coup Blixer 3. After comminution, 15 g celery was fortified at 10 ng/g with all residues from the LC multiresidue pesticide kit (cat.# 31971), which had been previously combined into a single mixture that day. The fortified celery was then shaken for a couple minutes to ensure uniform dispersion of the fortified pesticides in the slurry. Extraction was performed by adding 15 mL of a 1% acetic acid solution in acetonitrile (v/v) and AOAC 2007.01 QuEChERS salts (cat.# 25852). After centrifugation, 1 mL supernatant was added to a 2 mL dSPE vial containing magnesium sulfate, PSA, and GCB (cat.# 26218) for cleanup. After centrifugation, 100 μL of the 10 ng/mL extract was diluted with 900 μL water and injected onto the UHPLC.
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.
I cookies consentono varie funzionalità che renderanno più agevole la tua visita al sito Restek. Utilizzando questo sito, acconsenti all’uso dei cookies in accordo con le nostre linee guida. Per saperne di più, vedi la nostra politica sulla privacy.
Restek Domestic Customer Service
Grazie.
Il messaggio è stato inviato. La ricontatteremo non appena possibile.
Messaggio non inviato.
Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037