Questo cromatogramma potrebbe contenere analiti che sono sinonimi dei vostri parametri di ricerca.
LC Multiresidue Pesticide Mix Extracted from Brown Rice Flour with QuEChERS Slim Pouch on Raptor ARC-18 by LC-MS/MS
Peaks
tR (min)
Precursor Ion
Product Ion 1
Product Ion 2
1.
Cyromazine
0.747
167.1
68.1
43.1
2.
Methamidophos
1.318
142.0
94.0
125.1
3.
Formetanate
1.681
222.1
165.0
46.1
4.
Carbofuran
1.682
222.2
165.0
123.1
5.
Methabenzthiazuron
1.686
222.0
165.0
150.0
6.
Acephate
1.690
184.0
143.0
49.0
7.
Pymetrozine
1.708
218.1
105.0
78.0
8.
Aminocarb
1.716
209.1
137.1
152.1
9.
Propamocarb
1.735
189.1
102.0
144.1
10.
Omethoate
1.905
214.0
125.0
183.0
11.
Dinotefuran
1.972
203.1
129.1
87.1
12.
Aldicarb sulfoxide
2.010
207.1
89.0
132.1
13.
Butoxycarboxim
2.022
223.0
106.0
166.0
14.
Nitenpyram
2.049
271.0
225.0
56.0
15.
Aldicarb sulfone
2.062
240.2
148.0
86.0
16.
Carbendazim
2.090
192.0
160.0
131.9
17.
Oxamyl
2.154
237.1
72.0
90.0
18.
Flonicamid
2.234
230.1
203.0
148.0
19.
Methomyl
2.259
163.1
88.0
106.1
20.
Thiabendazole
2.284
201.8
92.2
104.0
21.
Thiamethoxam
2.289
292.1
211.1
181.1
22.
Fuberidazole
2.368
185.0
157.1
103.0
23.
Monocrotophos
2.375
224.1
127.0
193.1
24.
Mexacarbate
2.393
223.2
166.1
151.1
25.
Dioxacarb
2.397
224.1
167.0
77.1
26.
Dicrotophos
2.526
238.1
112.1
72.0
27.
Imidacloprid
2.536
256.1
175.0
209.0
28.
Clothianidin
2.545
250.0
169.0
113.0
29.
Dimethoate-d6 (IS)
2.652
236.2
205.2
131.2
30.
Fenuron
2.662
165.0
72.1
46.1
31.
Trichlorfon
2.667
257.0
108.9
220.8
32.
Dimethoate
2.668
230.0
199.0
125.0
33.
3-Hydroxycarbofuran
2.679
238.1
181.0
163.0
34.
Vamidothion
2.695
288.0
146.0
118.0
35.
Mevinphos
2.715
225.1
127.0
127.0
36.
Acetamiprid
2.724
223.0
126.0
56.1
37.
Propoxur
2.777
210.0
111.0
168.0
38.
Ethirimol
2.780
210.2
140.2
98.2
39.
Cymoxanil
2.805
199.1
128.2
111.2
40.
Thiacloprid
2.865
253.0
126.0
99.0
41.
Pirimicarb
2.896
239.2
72.0
182.1
42.
Aldicarb
3.022
208.2
116.2
89.2
43.
Tricyclazole
3.066
190.0
163.0
136.0
44.
Oxadixyl
3.076
279.1
219.1
132.1
45.
Carbetamide
3.085
237.1
192.0
118.1
46.
Simetryn
3.122
214.1
68.0
96.0
47.
Thiophanate-methyl
3.146
343.0
151.0
311.1
48.
Thidiazuron
3.150
221.1
102.1
127.9
49.
Bendiocarb
3.212
224.1
167.1
109.0
50.
Imazalil
3.225
297.1
159.0
41.1
51.
Prometon
3.227
226.1
142.1
184.0
52.
Metribuzin
3.230
215.1
187.1
131.0
53.
Secbumeton
3.232
226.2
170.2
100.2
54.
Terbumeton
3.235
226.1
114.1
170.1
55.
Sulfentrazone*
3.263
387.0
309.0
201.0
56.
Pyracarbolid
3.279
218.1
125.1
97.0
57.
Tebuthiuron
3.310
229.1
172.1
116.0
58.
Carbaryl
3.316
202.1
145.0
127.0
59.
Carboxin
3.326
236.1
143.0
87.1
60.
Monolinuron
3.373
215.1
126.0
148.0
61.
Fluometuron
3.381
233.1
72.1
46.1
62.
Diuron
3.382
233.1
72.1
46.0
63.
Ethiofencarb
3.406
226.0
107.0
164.0
64.
Ametryn
3.447
228.1
68.1
186.1
65.
Chlorotoluron
3.450
213.0
72.1
46.1
66.
Metobromuron
3.483
259.0
170.0
148.1
67.
Propham
3.500
180.1
120.2
77.1
68.
Flutriafol
3.508
302.0
70.1
123.0
69.
Methoprotryne
3.532
272.1
170.0
198.1
70.
Forchlorfenuron
3.536
248.1
129.0
93.0
71.
Isoprocarb
3.537
194.1
95.1
137.1
72.
Fenpropimorph
3.561
304.2
147.1
117.0
73.
Atrazine-d5 (SS)
3.575
221.2
179.2
101.3
74.
Isocarbophos
3.606
291.1
231.1
121.1
75.
Isoproturon
3.612
207.1
72.1
46.1
76.
Desmedipham
3.620
318.0
154.1
301.0
77.
Phenmedipham
3.623
318.1
108.1
93.1
78.
Spiroxamine
3.626
298.2
144.2
58.2
79.
Pyrimethanil
3.659
200.0
107.0
82.0
80.
Metalaxyl
3.691
280.1
220.1
192.1
81.
Chlorantraniliprole
3.730
484.0
452.8
285.8
82.
Cycluron
3.785
199.1
89.1
46.0
83.
Prometryn
3.830
242.1
158.0
200.2
84.
Linuron-d6 (SS)
3.843
255.1
160.1
185.2
85.
Linuron
3.854
249.0
160.0
182.0
86.
Thiofanox
3.876
242.1
57.2
184.0
87.
Fenobucarb
3.894
208.0
95.1
152.1
88.
Azoxystrobin
3.915
404.2
329.0
344.0
89.
Diethofencarb
3.924
268.1
226.1
124.0
90.
Ethofumesate
3.925
304.1
121.1
241.0
91.
Ethiprole
3.932
397.0
350.9
255.0
92.
Fludioxonil*
3.935
247.1
180.1
126.1
93.
Methiocarb
3.958
226.1
169.1
121.1
94.
Siduron
3.967
233.3
94.0
137.1
95.
Halofenozide
3.974
331.1
104.9
275.0
96.
Fenamidone
3.993
312.0
92.1
236.1
97.
Furalaxyl
3.995
302.1
242.1
95.0
98.
Acibenzolar-S-methyl
4.023
210.9
136.1
91.1
99.
Nuarimol
4.030
315.1
252.0
207.0
100.
Dimethomorph
4.044
388.2
300.9
165.1
101.
Boscalid
4.050
343.0
306.8
140.0
102.
Mandipropamid
4.067
412.1
328.1
125.0
103.
Flutolanil
4.079
324.1
262.0
242.0
104.
Promecarb
4.104
208.1
109.0
151.0
105.
Paclobutrazol
4.119
294.0
70.1
125.0
106.
Triadimenol
4.119
296.1
70.1
43.1
107.
Mepronil
4.161
270.1
91.1
119.0
108.
Cyproconazole
4.175
292.2
70.1
125.0
109.
Myclobutanil
4.195
289.2
70.1
125.1
110.
Chloroxuron
4.225
291.1
72.1
46.1
111.
Bupirimate
4.226
317.2
166.0
237.1
112.
Methoxyfenozide
4.230
369.2
149.0
313.1
113.
Triadimefon
4.287
294.0
69.0
197.0
114.
Bifenazate
4.290
301.1
198.0
170.1
115.
Cyprodinil
4.313
226.1
93.0
77.0
116.
Mefenacet
4.325
299.1
148.1
120.1
117.
Mepanipyrim
4.334
224.1
77.1
106.1
118.
Fluquinconazole
4.346
376.0
348.9
307.0
119.
Fenhexamid
4.383
302.1
97.1
55.1
120.
Fluoxastrobin
4.385
459.2
427.0
188.1
121.
Tetraconazole
4.387
372.0
159.0
70.0
122.
Bromuconazole isomer 1
4.392
376.0
159.0
159.0
123.
Butafenacil
4.411
492.1
330.9
179.9
124.
Iprovalicarb
4.412
321.2
119.0
91.1
125.
Flufenacet
4.427
364.1
152.0
194.1
126.
Triticonazole
4.429
318.0
70.0
125.0
127.
Cyazofamid
4.441
325.1
108.0
44.0
128.
Diflubenzuron
4.464
311.0
158.0
141.0
129.
Spirotetramat
4.478
374.1
330.1
302.0
130.
Fenarimol
4.510
331.0
267.9
189.1
131.
Fenbuconazole
4.516
337.0
125.0
70.1
132.
Epoxiconazole
4.529
330.0
121.1
101.0
133.
Etaconazole
4.552
328.1
159.0
55.0
134.
Fipronil*
4.571
436.9
332.0
252.0
135.
Neburon
4.635
275.0
57.1
88.1
136.
Flusilazole
4.646
316.1
247.1
165.1
137.
Fenoxycarb
4.653
302.2
88.1
116.1
138.
Picoxystrobin
4.674
368.0
145.0
205.0
139.
Rotenone
4.683
395.1
213.1
192.1
140.
Tebufenozide
4.719
353.2
133.1
105.0
141.
Dimoxystrobin
4.738
327.1
205.1
116.1
142.
Bromuconazole isomer 2
4.740
378.0
159.0
159.0
143.
Flubendiamide
4.745
700.0
408.0
274.0
144.
Diclobutrazol
4.764
328.0
70.1
159.0
145.
Carfentrazone ethyl
4.773
429.1
412.1
346.1
146.
Kresoxim-methyl
4.795
314.0
267.1
116.0
147.
Tebuconazole
4.827
308.0
70.1
124.9
148.
Spinosad A
4.840
732.5
142.1
98.1
149.
Penconazole
4.853
284.1
70.1
159.0
150.
Prothioconazole
4.857
344.0
189.0
154.0
151.
Zoxamide
4.893
336.1
187.0
159.0
152.
Famoxadone
4.933
392.2
331.1
238.0
153.
Diazinon-diethyl-d10 (IS)
4.961
315.2
170.2
154.3
154.
Hydramethylnon
4.979
495.2
323.2
45.2
155.
Triflumuron
4.986
359.1
156.0
111.0
156.
Prochloraz
4.986
376.0
308.0
70.1
157.
Hexaconazole
4.993
314.1
70.0
158.8
158.
Benalaxyl
5.021
326.2
148.0
208.1
159.
Metconazole
5.033
320.1
70.1
125.0
160.
Propiconazole
5.054
342.0
159.0
69.0
161.
Pyraclostrobin
5.076
388.0
194.0
163.1
162.
Clofentezine
5.080
303.0
138.0
102.0
163.
Bitertanol
5.120
338.2
269.2
70.1
164.
Spinosad D
5.142
746.5
142.0
98.0
165.
Benzoximate
5.171
364.0
199.1
105.0
166.
Diniconazole
5.184
326.1
70.0
158.9
167.
Thiobencarb
5.197
258.0
125.0
89.1
168.
Pencycuron
5.229
329.1
125.0
89.0
169.
Spinetoram
5.234
748.5
142.1
98.2
170.
Hexaflumuron*
5.351
459.0
439.0
175.0
171.
Triflumizole
5.366
346.1
278.0
73.1
172.
Indoxacarb
5.375
528.1
149.9
203.0
173.
Difenoconazole
5.380
406.1
251.1
152.0
174.
Ipconazole
5.426
334.2
70.0
124.9
175.
Trifloxystrobin
5.426
409.0
186.0
206.0
176.
Novaluron*
5.455
491.0
471.0
304.9
177.
Emamectin-benzoate B1b
5.463
872.2
158.2
82.1
178.
Clethodim
5.565
360.1
164.1
268.1
179.
Teflubenzuron
5.614
380.9
140.9
158.0
180.
Alanycarb
5.636
400.1
91.0
238.0
181.
Buprofezin
5.642
306.2
106.1
86.0
182.
Emamectin-benzoate B1a
5.644
886.5
158.0
82.1
183.
Benfuracarb
5.695
411.2
194.9
251.9
184.
Fluazinam*
5.726
463.0
415.9
397.9
185.
Metaflumizone*
5.728
505.1
302.1
328.0
186.
Furathiocarb
5.735
383.1
195.0
252.1
187.
Temephos
5.757
467.1
125.0
418.9
188.
Lufenuron
5.767
511.2
141.0
158.0
189.
Tebufenpyrad
5.778
334.0
117.0
145.0
190.
Pyriproxyfen
5.843
322.0
96.0
227.1
191.
Piperonyl butoxide
5.864
356.2
177.0
119.1
192.
Hexythiazox
5.924
353.2
228.0
168.1
193.
Quinoxyfen
5.935
308.1
197.0
162.0
194.
Flufenoxuron
5.984
489.1
158.0
141.0
195.
Propargite
6.088
368.1
231.1
175.0
196.
Etoxazole
6.099
360.2
141.0
57.1
197.
Spiromesifen
6.129
371.3
273.2
255.2
198.
Chlorfluazuron
6.165
539.8
382.9
158.0
199.
Spirodiclofen
6.269
428.3
71.1
313.1
200.
Fenpyroximate
6.283
422.1
366.1
138.1
201.
Pyridaben
6.442
365.2
147.0
309.1
202.
Eprinomectin
6.466
914.6
186.1
154.1
203.
Abamectin B1a
6.544
890.6
305.4
567.2
204.
Fenazaquin
6.559
307.1
161.0
131.1
205.
Doramectin
6.733
916.6
331.2
593.4
206.
Ivermectin
6.893
892.6
551.4
569.4
*Detected in ESI- mode
LC_FS0521
Column
Raptor ARC-18 (cat.# 9314A12)
Dimensions:
100 mm x 2.1 mm ID
Particle Size:
2.7 µm
Pore Size:
90 Å
Guard Column:
Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9314A0252)
Temp.:
50 °C
Sample
LC multiresidue pesticide kit (cat.# 31971)
Diluent:
Water:acetonitrile 9:1
Conc.:
1 ng/mL see notes for details
Inj. Vol.:
5 µL
Mobile Phase
A:
0.2% Formic acid, 2 mM ammonium formate in water
B:
0.2% Formic acid, 2 mM ammonium formate in methanol
Time (min)
Flow (mL/min)
%A
%B
0.00
0.4
95
5
2.00
0.4
40
60
4.00
0.4
25
75
6.00
0.4
0
100
7.50
0.4
0
100
7.51
0.4
95
5
9.50
0.4
95
5
Detector
MS/MS
Ion Mode:
ESI+/ESI-
Mode:
Scheduled MRM
Instrument
UHPLC
Notes
Although the ten LC multiresidue pesticides kit mixes are formulated to ensure maximum long-term stability and reliability as packaged, stability may become an issue when a large number of compounds with different chemical functionalities are combined together into a single mix. This should be taken into consideration for quantitative analysis.
Sample Preparation: Brown rice flour (10 g), purchased from a local market, was mixed with 10 mL water. After mixing for 10 min, the brown rice flour was fortified at 10 ng/g with all residues from the LC multiresidue pesticide kit (cat.# 31971), which had been previously combined into a single mixture that day. The fortified brown rice flour suspension was then mixed for 30 min to ensure uniform dispersion of the added pesticide residues in the brown rice flour suspension. Extraction was performed using 10 mL of acetonitrile and original unbuffered QuEChERS salts (cat.# 25848). After centrifugation, 1 mL supernatant was added to a 2 mL dSPE vial containing magnesium sulfate, PSA, and C18 (cat.# 26125) for cleanup. After centrifugation, 100 μL of the 10 ng/mL extract was diluted with 900 μL water and injected onto the UHPLC.
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.
I cookies consentono varie funzionalità che renderanno più agevole la tua visita al sito Restek. Utilizzando questo sito, acconsenti all’uso dei cookies in accordo con le nostre linee guida. Per saperne di più, vedi la nostra politica sulla privacy.
Restek Domestic Customer Service
Grazie.
Il messaggio è stato inviato. La ricontatteremo non appena possibile.
Messaggio non inviato.
Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037