Questo cromatogramma potrebbe contenere analiti che sono sinonimi dei vostri parametri di ricerca.
Food Industry FAMEs on Rt-2560 by AOCS Method Ce-1h-05
Peaks
tR (min)
Conc. (µg/mL)
Structural Nomenclature
1.
Methyl caproate
5.830
400
C6:0
2.
Methyl octanoate
6.092
400
C8:0
3.
Methyl decanoate
6.539
400
C10:0
4.
Methyl undecanoate
6.870
200
C11:0
5.
Methyl dodecanoate
7.302
400
C12:0
6.
Methyl tridecanoate
7.866
200
C13:0
7.
Methyl myristate
8.603
400
C14:0
8.
Methyl myristoleate
9.509
200
C14:1 (c9)
9.
Methyl pentadecanoate
9.563
200
C15:0
10.
Methyl pentadecenoate
10.733
200
C15:1 (C10)
11.
Methyl palmitate
10.822
600
C16:0
12.
Methyl palmitoleate
12.080
200
C16:1 (c9)
13.
Methyl heptadecanoate
12.453
200
C17:0
14.
Methyl heptadecenoate
14.065
200
C17:1 (c10)
15.
Methyl stearate
14.597
400
C18:0
16.
Methyl octadecenoate
15.817
200
C18:1 (t9)
17.
Methyl oleate
16.393
400
C18:1 (c9)
18.
Methyl linolelaidate
18.037
200
C18:2 (t9,t12)
19.
Methyl linoleate
19.563
200
C18:2 (c9,c12)
20.
Methyl arachidate
21.048
400
C20:0
21.
Methyl linolenate
22.417
200
C18:3 (c6,c9,c12)
22.
Methyl eicosenoate
23.849
200
C20:1 (c11)
23.
Methyl linolenate
24.242
200
C18:3 (c9,c12,c15)
24.
Methyl heneicosanoate
25.794
200
C21:0
25.
Methyl eicosadienoate
29.073
200
C20:2 (c11,c14)
26.
Methyl behenate
32.095
400
C22:0
27.
Methyl eicosatrienoate
33.613
200
C20:3 (c8,c11,c14)
28.
Methyl erucate
36.531
200
C22:1 (c13)
29.
Methyl eicosatrienoate
36.727
200
C20:3 (c11,c14,c17)
30.
Methyl arachidonate
37.548
200
C20:4 (c5,c8,c11,c14)
31.
Methyl tricosanoate
40.227
200
C23:0
32.
Methyl docosadienoate
45.045
200
C22:2 (c13,c16)
33.
Methyl eicosapentaenoate
48.043
200
C20:5 (c5,c8,c11,c14,c17)
34.
Methyl lignocerate
51.086
400
C24:0
35.
Methyl nervonate
58.002
200
C24:1 (c15)
36.
Methyl docosahexaenoate
86.473
200
C22:6 (c4,c7,c10,c13,c16,c19)
GC_FF1349
Column
Rt-2560, 100 m, 0.25 mm ID, 0.20 µm (cat.# 13198)
Sample
Food industry FAME mix (cat.# 35077)
Diluent:
Hexane
Conc.:
10,000 µg/mL total concentration
Injection
Inj. Vol.:
1 µL split (split ratio 20:1)
Liner:
Topaz 4.0 mm ID Precision inlet liner w/wool (cat.# 23305)
Inj. Temp.:
250 °C
Oven
Oven Temp.:
180 °C (hold 90 min)
Carrier Gas
H2, constant flow
Flow Rate:
1.75 mL/min
Detector
FID @ 250 °C
Constant Column + Constant Make-up:
52 mL/min
Hydrogen flow:
40 mL/min
Air flow:
400 mL/min
Data Rate:
50 Hz
Instrument
Agilent 7890A GC
Notes
Hydrogen flow optimized to achieve effective linear velocity (https://blog.restek.com/?p=52224). C4:0 Methyl butyrate (623-42-7) elutes in the solvent front.
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.
I cookies consentono varie funzionalità che renderanno più agevole la tua visita al sito Restek. Utilizzando questo sito, acconsenti all’uso dei cookies in accordo con le nostre linee guida. Per saperne di più, vedi la nostra politica sulla privacy.
Restek Domestic Customer Service
Grazie.
Il messaggio è stato inviato. La ricontatteremo non appena possibile.
Messaggio non inviato.
Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037