Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Peaks tR (min)
1. 1,4-Dioxane-d8 (IS) 1.32
2. N-Nitrosodimethylamine 1.43
3. Pyridine 1.45
4. 2-Fluorophenol (SS) 1.87
5. Phenol-d6 (SS) 2.20
6. Phenol 2.20
7. Aniline 2.23
8. Bis(2-chloroethyl) ether 2.24
9. 2-Chlorophenol 2.28
10. 1,3-Dichlorobenzene 2.34
11. 1,4-Dichlorobenzene-d4 (IS) 2.35
12. 1,4-Dichlorobenzene 2.36
13. Benzyl alcohol 2.40
14. 1,2-Dichlorobenzene 2.42
15. 2-Methylphenol 2.44
16. Bis(2-chloroisopropyl)ether 2.45
17. 4-Methylphenol 2.50
18. 3-Methylphenol 2.50
19. N-Nitrosodi-N-propylamine 2.50
20. Hexachloroethane 2.56
21. Nitrobenzene-d5 (SS) 2.57
22. Nitrobenzene 2.58
23. Isophorone 2.67
24. 2-Nitrophenol 2.71
25. 2,4-Dimethylphenol 2.71
26. Benzoic acid 2.74
27. Bis(2-chloroethoxy)methane 2.75
28. 2,4-Dichlorophenol 2.80
29. 1,2,4-Trichlorobenzene 2.84
30. Naphthalene-D8 (IS) 2.87
31. Naphthalene 2.88
32. 4-Chloroaniline 2.89
33. Hexachlorobutadiene 2.93
34. 4-Chloro-3-methylphenol 3.09
35. 2-Methylnaphthalene 3.17
36. 1-Methylnaphthalene 3.21
37. Hexachlorocyclopentadiene 3.23
38. 2,4,6-Trichlorophenol 3.28
39. 2,4,5-Trichlorophenol 3.30
40. 2-Fluorobiphenyl (SS) 3.32
41. 2-Chloronaphthalene 3.38
42. 2-Nitroaniline 3.41
43. 1,4-Dinitrobenzene 3.46
44. Dimethyl phthalate 3.49
45. 1,3-Dinitrobenzene 3.50
46. 2,6-Dinitrotoluene 3.51
47. 1,2-Dinitrobenzene 3.54
Peaks tR (min)
48. Acenaphthylene 3.56
49. 3-Nitroaniline 3.59
50. Acenaphthene-d10 (IS) 3.62
51. Acenaphthene 3.63
52. 2,4-Dinitrophenol 3.63
53. 4-Nitrophenol 3.65
54. 2,4-Dinitrotoluene 3.69
55. Dibenzofuran 3.70
56. 2,3,5,6-Tetrachlorophenol 3.73
57. 2,3,4,6-Tetrachlorophenol 3.75
58. Diethyl Phthalate 3.79
59. 4-Chlorophenyl phenyl ether 3.84
60. Fluorene 3.85
61. 4-Nitroaniline 3.85
62. 4,6-Dinitro-2-methylphenol 3.86
63. N-Nitrosodiphenylamine (as diphenylamine) 3.89
64. N-N-Diphenylhydrazine (as azobenzene) 3.91
65. 2,4,6-Tribromophenol (SS) 3.95
66. 4-Bromophenyl phenyl ether 4.06
67. Hexachlorobenzene 4.09
68. Pentachlorophenol 4.17
69. Phenanthrene-d10 (IS) 4.26
70. Phenanthrene 4.27
71. Anthracene 4.29
72. Carbazole 4.36
73. di-n- Butyl phthalate 4.49
74. Fluoranthene 4.79
75. Pyrene 4.79
76. Benzidine 4.84
77. Pyrene-d10 (IS) 4.89
78. p- Terphenyl-d14 (SS)4.96
79. Butyl benzyl phthalate 5.19
80. 3,3'-Dimethylbenzidine 5.20
81. Bis(2-ethylhexyl) adipate 5.22
82. 3,3'-Dichlorobenzidine 5.52
83. Bis(2-ethylhexyl) phthalate 5.53
84. Benz[a]anthracene 5.55
85. Chrysene-d12 (IS) 5.56
86. Chrysene 5.58
87. Di-n- octyl phthalate 6.02
88. Benzo[b]fluoranthene 6.40
89. Benzo[k]fluoranthene 6.42
90. Benzo[a]pyrene 6.71
91. Perylene-d12 (IS) 6.77
92. Indeno[1,2,3-cd]pyrene 7.98
93. Dibenz[a,h]anthracene 8.01
94. Benzo[ghi]perylene 8.30
GC_EV1475
Rxi-5Sil MS, 20 m, 0.15 mm ID, 0.15 µm (cat.# 43816) 8270 MegaMix (cat.# 31850) 8270 Benzidines mix (cat.# 31852) Benzoic acid (cat.# 31879) Revised B/N surrogate mix (cat.# 31888) Acid surrogate mix (4/89 SOW) (cat.# 31063) Revised SV internal standard mix (cat.# 31886)
Methylene chloride 20 µg/mL (IS/SS 20 µg/mL) 1 µL split (split ratio 20:1) Topaz 4 mm single taper w/wool (cat.# 23303) 275 °C 45 °C (hold 0.5 min) to 285 °C at 56.5 °C/min to 305 °C at 6 °C/min to 330 °C at 60.5 °C/min (hold 2.5 min) He, constant flow 1.0 mL/min MS Scan 280 °C Quadrupole 330 °C 180 °C 70 eV 1.3 min DFTPP EI 39-550 amu 9.8 scans/sec Agilent 7890B GC & 5977A MSD Analyzed using a 208 V oven equipped with the GC Accelerator kit (cat.# 23849).