Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi-PAH

PeaksConc.
(µg/mL)
1.Naphthalene-d82.0
2.Naphthalene0.62
3.2-Methylnaphthalene0.13
4.Biphenyl0.24
5.Acenaphthylene0.40
6.Acenaphthene-d102.0
7.Acenaphthene0.37
8.Fluorene0.33
9.Dibenzothiophene0.19
10.Phenanthrene-d102.0
11.Phenanthrene0.63
12.Anthracene0.29
13.4H-Cyclopenta[def]phenanthrene0.10
14.Fluoranthene0.49
15.Pyrene0.51
16.Benzo[c]fluorene0.13
17.Benzo[ghi]fluoranthene0.15
18.Benzo[c]phenanthrene0.20
19.Benz[a]anthracene0.32
20.Chrysene-D122.0
21.Cyclopenta[cd]pyrene0.21
22.Triphenylene0.18
23.Chrysene0.33
24.5-Methylchrysene0.13
PeaksConc.
(µg/mL)
25.Benzo[b]fluoranthene0.47
26.Benzo[k]fluoranthene0.27
27.Benzo[j]fluoranthene0.30
28.Benzo[a]fluoranthene0.10
29.Benzo[e]pyrene0.32
30.Benzo[a]pyrene-d122.0
31.Benzo[a]pyrene0.33
32.Perylene-d122.0
33.Perylene0.32
34.Dibenzo[a,j]anthracene0.20
35.Dibenzo[a,c]anthracene0.13
36.Indeno[1,2,3-cd]pyrene0.32
37.Dibenz[a,h]anthracene0.32
38.Benzo[b]chrysene0.18
39.Picene0.14
40.Benzo[ghi]perylene0.37
41.Anthanthrene0.10
42.Dibenzo[b,k]fluoranthene0.070
43.Dibenzo[a,l]pyrene0.13
44.Dibenzo[a,e]pyrene0.22
45.Coronene-d122.0
46.Coronene0.10
47.Dibenzo[a,i]pyrene0.13
48.Dibenzo[a,h]pyrene0.13
image
GC_EV1394
ColumnRxi-PAH, 60 m, 0.25 mm ID, 0.10 µm (cat.# 49317)
SampleSV internal standard mix (cat.# 31206)
Coronene-d12 (CIL DLM-2715)
Benzo[a]pyrene-d12 (CIL DLM-258-0)
Aromatics in toluene (NIST SRM-2260a)
PAH native stock solution (Wellington PAH-STK-B)
Diluent:Dichloromethane
Injection
Inj. Vol.:1 µL split (split ratio 10:1)
Liner:Premium 4 mm Precision liner w/wool (cat.# 23305.1)
Inj. Temp.:275 °C
Split Vent Flow Rate:19.5 mL/min
Oven
Oven Temp.:110 °C (hold 1.6 min) to 210 °C at 24 °C/min to 295 °C at 1.9 °C/min to 350 °C at 3.7 °C/min (hold 6 min)
Carrier GasHe, constant flow
Flow Rate:1.95 mL/min
DetectorMS
Mode:SIM
SIM Program:
GroupStart Time
(min)
Ion(s) (m/z)Dwell (ms)
13.09102.1, 108.1, 128.1, 136.2 40
25.69115.1, 142.1 40
36.2376.1, 141.1, 154.1, 156.2 40
46.9575.6, 76.1, 91.1, 152.1, 153.1, 155.1, 162.2, 170.2 20
57.9382.4, 165.1 40
69.19139.1, 152.1, 160.2, 178.1, 184.1, 188.2 40
711.7894.6, 165.1, 190.1, 192.1 40
814.19101.1, 202.1 40
916.60101.1, 202.1 40
1018.4992.1, 184.1 40
1119.58108, 216 40
1222.3196.1, 212.2 40
1324.92113.1, 226.1, 228.1 40
1426.27113.1, 114.0, 120.1, 226.1, 228.1, 240.1 40
1528.75154.1, 252.1 35
1630.62119.8, 242.2 40
1735.29126.1, 252.1 40
1838.56125.1, 252.1 40
1939.23126.1, 252.1 40
2040.71125.1, 126.1, 132.1, 252.1, 264.1 40
2142.91125, 132.2, 252.1, 264.1 40
2244.35252.1, 268.1 40
2348.41139.1, 139.5, 278.1, 279.1 40
2452.13139.1, 139.5, 278.1, 279.1 40
2553.70138.1, 139.1, 278.1 40
2654.97138.1, 276.1 40
2755.92138.1, 276.1 40
2857.04132.6, 267.1 40
2959.69151.0, 302.1 40
3063.27150, 151, 156.1, 300.1, 302.1, 312.1 40
3164.78151.0, 302.1 40
Transfer Line Temp.:330 °C
Analyzer Type:Quadrupole
Source Type:Extractor
Extractor Lens:9 mm ID
Source Temp.:350 °C
Quad Temp.:200 °C
Solvent Delay Time:3 min
Tune Type:DFTPP
Ionization Mode:EI
InstrumentAgilent 7890B GC & 5977A MSD
NotesPerforms the separation of two critical sets of isobars:
1. Cyclopenta[c,d]pyrene, triphenylene, and chrysene
2. Benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene
Download PDF

relativo alle ricerche nella libreria dei cromatogrammi

benzo[j]fluoranthene

,

chrysene

,

triphenylene

,

isobaric

,

isobar

,

benzofluoranthenes

Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.


Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us