This site requires that Javascript be enabled. Please enable Javascript in your browser.
Questo cromatogramma potrebbe contenere analiti che sono sinonimi dei vostri parametri di ricerca.
Semivolatiles on Rtx-5 with 5 m Integra-Guard by EPA Method 8270
Peaks
1. 1,4-Dioxane-D8 (IS)
2. 1,4-Dioxane
3. Pyridine
4. N-Nitrosodimethylamine
5. Ethyl methacrylate
6. 2-Picoline
7. N-Nitrosomethylethylamine
8. Methyl methanesulfonate
9. 2-Fluorophenol (SS)
10. N-Nitrosodiethylamine
11. Ethyl methanesulfonate
12. Benzaldehyde
13. Phenol-D6 (SS)
14. Phenol
15. Aniline
16. Pentachloroethane
17. Bis(2-chloroethyl) ether
18. 2-Chlorophenol
19. 1,3-Dichlorobenzene
20. Dichlorobenzene-D4 (IS)
21. 1,4-Dichlorobenzene
22. Benzyl alcohol
23. 1,2-Dichlorobenzene
24. 2-Methylphenol
25. Bis(2-Chloroisopropyl)ether
26. 4-Methylphenol
27. 3-Methylphenol
28. Acetophenone
29. Nitrosopyrrolidine
30. N-Nitrosodipropylamine
31. N-Nitrosomorpholine
32. o- Toluidine
33. Hexachloroethane
34. Nitrobenzene-D5 (SS)
35. Nitrobenzene
36. N-Nitrosopiperidine
37. Isophorone
38. 2-Nitrophenol
39. 2,4-Dimethylphenol
40. Benzoic acid
41. Bis(2-chloroethoxy)methane
42. 2,4-Dichlorophenol
43. Phenyl-tert- butylamine (Phentermine)
44. 1,2,4-Trichlorobenzene
45. Naphthalene-D8 (IS)
46. Naphthalene
47. 4-Chloroaniline
48. 2,6-Dichlorophenol
49. Hexachloropropene
50. Hexachlorobutadiene
51. Caprolactam
52. N-Nitroso-N-butylamine
53. 1,4-Phenylenediamine
54. 4-Chloro-3-methylphenol
55. Isosafrole I
56. 2-Methylnaphthalene
57. 1-Methylnaphthalene
58. Isosafrole II
59. 1,2,4,5-Tetrachlorobenzene
60. Hexachlorocyclopentadiene
61. 2,4,6-Trichlorophenol
62. 2,4,5-Trichlorophenol
63. 2-Fluorobiphenyl (SS)
64. Safrole
65. Biphenyl
66. 2-Chloronaphthalene
67. 1-Chloronaphthalene
68. Diphenyl ether
69. 2-Nitroaniline
70. 1,4-Naphthoquinone
71. 1,2-Dinitrobenzene
72. Dimethyl phthalate
Peaks
73. 1,3-Dinitrobenzene
74. 2,6-Dinitrotoluene
75. Acenaphthylene
76. 1,4-Dinitrobenzene
77. 3-Nitroaniline
78. Acenaphthene-D10 (IS)
79. Acenaphthene
80. 2,4-Dinitrophenol
81. 4-Nitrophenol
82. Dibenzofuran
83. 2,4-Dinitrotoluene
84. Pentachlorobenzene
85. 1-Naphthalamine
86. 2,3,5,6-Tetrachlorophenol
87. 2,3,4,6-Tetrachlorophenol
88. 2-Naphthalamine
89. Diethyl Phthalate
90. 4-Chlorophenyl phenyl ether
91. Fluorene
92. 2-Methyl-5-nitroaniline
93. 4-Nitroaniline
94. 4,6-Dinitro-2-methylphenol
95. N-nitrosodiphenylamine (as diphenylamine)
96. N,N'-Diphenylhydrazine (as Azobenzene)
97. 2,4,6-Tribromophenol (SS)
98. 1,3,5-Trinitrobenzene
99. Diallate
100. Phenacetin
101. 4-Bromophenyl phenyl ether
102. Atrazine
103. Hexachlorobenzene
104. 4-Aminobiphenyl
105. Propyzamide
106. Pentachlorophenol
107. Pentachloronitrobenzene
108. Phenanthrene-D10 (IS)
109. Phenanthrene
110. Anthracene
111. Carbazole
112. di-n- Butyl phthalate
113. 4-Nitroquinoline 1-oxide
114. Isodrin
115. Fluoranthene
116. Benzidine
117. Pyrene-D10 (SS)
118. Pyrene
119. Aramite I
120. p- Terphenyl-D14 (SS)
121. Aramite II
122. Dimethylaminoazobenzene
123. Chlorobenzilate
124. 3,3'-Dimethylbenzidine
125. Butyl benzyl phthalate
126. Kepone
127. Bis(2-ethylhexyl) adipate
128. 2-(Acetylamino)fluorene
129. Benz[a]anthracene
130. 3,3'-Dichlorobenzidine
131. Chrysene-D12 (IS)
132. Chrysene
133. Bis(2-ethylhexyl) phthalate
134. Di-n- octyl phthalate
135. Benzo[b]fluoranthene
136. Benzo[k]fluoranthene
137. 7,12-Dimethylbenzo[a]anthracene
138. Benzo[a]pyrene
139. Perylene-D12 (IS)
140. 3-Methylcholanthrene
141. Dibenz[a,j]acridine
142. Indeno[1,2,3-cd]pyrene
143. Dibenz[a,h]anthracene
144. Benzo[ghi]perylene
GC_EV1357
Rtx-5 w/ 5 m Integra-Guard, 30 m, 0.25 mm ID, 0.50 µm (cat.# 10238-124) Revised SV internal standard mix (cat.# 31886) Revised B/N surrogate mix (cat.# 31888) Acid surrogate mix (4/89 SOW) (cat.# 31063) 8270 MegaMix (cat.# 31850) 8270 Benzidines mix (cat.# 31852) Benzoic acid (cat.# 31879) Appendix IX mix #1, revised (cat.# 32459) Appendix IX mix #2 (cat.# 31806)
Dichloromethane 10 ng/µL (IS and SS at 20 ng/µL) 1 µL pulsed splitless (hold 0.7 min) Premium 4 mm single taper w/wool (cat.# 23303.5) 270 °C 30 psi (206.8kPa) 0.8 min 100 mL/min 40 °C (hold 2 min) to 90 °C at 12.5 °C/min to 246 °C at 25 °C/min to 295 °C at 3 °C/min to 325 °C at 6 °C/min (hold 3 min) He, constant flow 2.08 mL/min MS Scan Group Start Time (min) Scan Range (amu) Scan Rate (scans/sec) 1 3.5 35-550 5.6
320 °C Quadrupole Inert 9mm ID 350 °C 180 °C 69.9 eV 3.5 min EI Agilent 7890A GC & 5975C MSD
Download PDF relativo alle ricerche nella libreria dei cromatogrammi
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.