9-Minute Semivolatiles Analysis with Appendix IX on Rxi-5ms by U.S. EPA Method 8270D
Peaks
1.
1,4-Dioxane-d8 (IS)
2.
1,4-Dioxane
3.
N-Nitrosodimethylamine
4.
Pyridine
5.
Ethyl methacrylate
6.
2-Picoline
7.
N-Nitrosomethylethylamine
8.
Methyl methanesulfonate
9.
2-Fluorophenol (SS)
10.
N-Nitrosodiethylamine
11.
Ethyl methanesulfonate
12.
Benzaldehyde
13.
Phenol-d6 (SS)
14.
Phenol
15.
Aniline
16.
Pentachloroethane
17.
Bis(2-chloroethyl) ether
18.
2-Chlorophenol
19.
1,3-Dichlorobenzene
20.
1,4-Dichlorobenzene-d4 (IS)
21.
1,4-Dichlorobenzene
22.
Benzyl alcohol
23.
1,2-Dichlorobenzene
24.
2-Methylphenol
25.
Bis(2-Chloroisopropyl)ether
26.
p-Cresol (4-methylphenol)
27.
m-Cresol (3-methylphenol)
28.
Acetophenone
29.
N-Nitrosopyrrolidine
30.
N-Nitrosomorpholine
31.
N-Nitrosodi-n-propylamine
32.
o-Toluidine
33.
Hexachloroethane
34.
Nitrobenzene-d5 (SS)
35.
Nitrobenzene
36.
N-Nitrosopiperidine
37.
Isophorone
38.
2-Nitrophenol
39.
2,4-Dimethylphenol
40.
Bis(2-chloroethoxy)methane
41.
Benzoic acid
42.
2,4-Dichlorophenol
43.
α,α-Dimethylphenethylamine (Phentermine)
44.
1,2,4-Trichlorobenzene
45.
Naphthalene-d8 (IS)
46.
Naphthalene
47.
4-Chloroaniline
48.
2,6-Dichlorophenol
49.
Hexachloropropene
50.
Hexachlorobutadiene
51.
Caprolactam
52.
N-Nitroso-n-butylamine
53.
1,4-Phenylenediamine
54.
4-Chloro-3-methylphenol
55.
Isosafrole I (isomer)
56.
2-Methylnaphthalene
57.
1-Methylnaphthalene
58.
Isosafrole II (isomer)
59.
1,2,4,5-Tetrachlorobenzene
60.
Hexachlorocyclopentadiene
61.
2,4,6-Trichlorophenol
62.
2,4,5-Trichlorophenol
63.
2-Fluorobiphenyl (SS)
64.
Safrole
65.
Biphenyl
66.
2-Chloronaphthalene
67.
1-Chloronaphthalene
68.
Diphenyl ether
69.
2-Nitroaniline
70.
1,4-Naphthoquinone
71.
1,4-Dinitrobenzene
72.
Dimethyl phthalate
Peaks
73.
1,3-Dinitrobenzene
74.
2,6-Dinitrotoluene
75.
Acenaphthylene
76.
1,2-Dinitrobenzene
77.
3-Nitroaniline
78.
Acenaphthene-d10 (IS)
79.
Acenaphthene
80.
2,4-Dinitrophenol
81.
4-Nitrophenol
82.
Dibenzofuran
83.
Pentachlorobenzene
84.
2,4-Dinitrotoluene
85.
1-Naphthalamine
86.
2,3,5,6-Tetrachlorophenol
87.
2-Naphthalamine
88.
2,3,4,6-Tetrachlorophenol
89.
Diethyl phthalate
90.
4-Chlorophenyl phenyl ether
91.
Fluorene
92.
2-Methyl-5-nitroaniline
93.
4-Nitroaniline
94.
4,6-Dinitro-2-methylphenol
95.
N-Nitrosodiphenylamine
96.
1,2-Diphenylhydrazine (as Azobenzene)
97.
2,4,6-Tribromophenol (SS)
98.
1,3,5-Trinitrobenzene
99.
Diallate
100.
Phenacetin
101.
4-Bromophenyl phenyl ether
102.
Hexachlorobenzene
103.
Atrazine
104.
4-Aminobiphenyl
105.
Pentachlorophenol
106.
Propyzamide
107.
Pentachloronitrobenzene
108.
Phenanthrene-d10 (IS)
109.
Phenanthrene
110.
Anthracene
111.
Carbazole
112.
di-n-Butyl phthalate
113.
4-Nitroquinoline oxide
114.
Isodrin
115.
Fluoranthene
116.
Benzidine
117.
Pyrene-d10 (SS)
118.
Pyrene
119.
Aramite I (isomer)
120.
p-Terphenyl-d14 (SS)
121.
Aramite II (isomer)
122.
Dimethylaminoazobenzene
123.
Chlorobenzilate
124.
3,3'-Dimethylbenzidine
125.
Kepone
126.
n-Butyl benzyl phthalate
127.
Bis(2-ethylhexyl) adipate
128.
2-Acetylaminofluorine
129.
3,3'-Dichlorobenzidine
130.
Chrysene-d12 (IS)
131.
Benz[a]anthracene
132.
Chrysene
133.
Bis(2-ethylhexyl) phthalate
134.
Di-n-octyl phthalate
135.
Benzo[b]fluoranthene
136.
Benzo[k]fluoranthene
137.
7,12-Dimethylbenzo[a]anthracene
138.
Benzo[a]pyrene
139.
Perylene-d12 (IS)
140.
3-Methylcholanthrene
141.
Dibenz[a,j]acridine
142.
Indeno[1,2,3-cd]pyrene
143.
Dibenz[a,h]anthracene
144.
Benzo[ghi]perylene
GC_EV1328
Column
Rxi-5ms, 10 m, 0.18 mm ID, 0.18 µm
using Rxi-5ms 2 m, 0.18 mm ID,
with 0.4 mm OD matched press-fit, BGB (cat.# 2525LD)
Sample
Revised SV internal standard mix (cat.# 31886)
Revised B/N surrogate mix (cat.# 31888)
Acid surrogate mix (4/89 SOW) (cat.# 31063)
8270 MegaMix (cat.# 31850)
8270 Benzidines mix (cat.# 31852)
Benzoic acid (cat.# 31879)
Appendix IX mix #1, revised (cat.# 32459)
Appendix IX mix #2 (cat.# 31806)
Diluent:
Dichloromethane
Conc.:
20 µg/mL (1.0 ng on column)
Injection
Inj. Vol.:
0.5 µL split (split ratio 10:1)
Liner:
2 mm Split Precision liner w/deact. wool (cat.# 20824)
Inj. Temp.:
275 °C
Split Vent Flow Rate:
9 mL/min
Oven
Oven Temp.:
35 °C (hold 0.5 min) to 115 °C at 95 °C/min to 240 °C at 65 °C/min to 265 °C at 6 °C/min to 330 °C at 35 °C/min (hold 1 min)
Carrier Gas
He, constant flow
Flow Rate:
0.9 mL/min
Detector
MS
Mode:
Scan
Scan Program:
Group
Start Time (min)
Scan Range (amu)
Scan Rate (scans/sec)
1
0.75
35-450
11.47
2
3.67
35-450
6.48
Transfer Line Temp.:
320 °C
Analyzer Type:
Quadrupole
Source Type:
Inert
Drawout Plate:
3mm ID
Source Temp.:
330 °C
Quad Temp.:
180 °C
Electron Energy:
70 eV
Solvent Delay Time:
0.75 min
Tune Type:
BFB
Ionization Mode:
EI
Instrument
Agilent 7890A GC & 5975C MSD
Notes
The 10 m analytical and 2 m guard columns used in this application are segments of a 20 m x 0.18 mm ID x 0.18 µm df Rxi-5ms column (cat.# 13402). The 20 m column was cut to yield one 10 m analytical column and five 2 m guard columns.
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.
I cookies consentono varie funzionalità che renderanno più agevole la tua visita al sito Restek. Utilizzando questo sito, acconsenti all’uso dei cookies in accordo con le nostre linee guida. Per saperne di più, vedi la nostra politica sulla privacy.
Restek Domestic Customer Service
Grazie.
Il messaggio è stato inviato. La ricontatteremo non appena possibile.
Messaggio non inviato.
Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037