This site requires that Javascript be enabled. Please enable Javascript in your browser.
Questo cromatogramma potrebbe contenere analiti che sono sinonimi dei vostri parametri di ricerca.
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Peaks
1. 1,4-Dioxane-d8 (IS)
2. 1,4-Dioxane
3. N-Nitrosodimethylamine
4. Pyridine
5. 2-Fluorophenol (SS)
6. Phenol-d6 (SS)
7. Phenol
8. Aniline
9. Bis(2-chloroethyl)ether
10. 2-Chlorophenol
11. 1,3-Dichlorobenzene
12. 1,4-Dichlorobenzene-D4 (IS)
13. 1,4-Dichlorobenzene
14. Benzyl alcohol
15. 1,2-Dichlorobenzene
16. 2-Methylphenol
17. Bis(2-chloroisopropyl)ether
18. 4-Methylphenol
19. 3-Methylphenol
20. N-Nitroso-di-n- propylamine
21. Hexachloroethane
22. Nitrobenzene-D5 (SS)
23. Nitrobenzene
24. Isophorone
25. 2-Nitrophenol
26. 2,4-Dimethylphenol
27. Benzoic acid
28. Bis(2-chloroethoxy)methane
29. 2,4-Dichlorophenol
30. 1,2,4-Trichlorobenzene
31. Naphthalene-D8 (IS)
32. Naphthalene
33. 4-Chloroaniline
34. Hexachlorobutadiene
35. 4-Chloro-3-methylphenol
36. 2-Methylnaphthalene
37. 1-Methylnaphthalene
38. Hexachlorocyclopentadiene
39. 2,4,6-Trichlorophenol
40. 2,4,5-Trichlorophenol
41. 2-Fluorobiphenyl (SS)
42. 2-Chloronaphthalene
43. 2-Nitroaniline
44. 1,4-Dinitrobenzene
45. Dimethyl phthalate
46. 1,3-Dinitrobenzene
47. 2,6-Dinitrotoluene
Peaks
48. 1,2-Dinitrobenzene
49. Acenaphthylene
50. 3-Nitroaniline
51. Acenaphthene-d10 (IS)
52. Acenaphthene
53. 2,4-Dinitrophenol
54. 4-Nitrophenol
55. 2,4-Dinitrotoluene
56. Dibenzofuran
57. 2,3,5,6-Tetrachlorophenol
58. 2,3,4,6-Tetrachlorophenol
59. Diethyl phthalate
60. 4-Chlorophenyl phenyl ether
61. Fluorene
62. 4-Nitroaniline
63. 4,6-Dinitro-2-methylphenol
64. N-nitrosodiphenylamine
65. 1,2-Diphenylhydrazine
66. 2,4,6-Tribromophenol (SS)
67. 4-Bromophenyl phenyl ether
68. Hexachlorobenzene
69. Pentachlorophenol
70. Phenanthrene-D10 (IS)
71. Phenanthrene
72. Anthracene
73. Carbazole
74. di-n- Butyl phthalate
75. Fluoranthene
76. Benzidine
77. Pyrene-D10 (SS)
78. Pyrene
79. p- Terphenyl-d14 (SS)
80. 3,3'-Dimethylbenzidine
81. Butyl benzyl phthalate
82. Bis(2-ethylhexyl)adipate
83. 3,3'-Dichlorobenzidine
84. Benz[a]anthracene
85. Chrysene-D12 (IS)
86. Bis(2-ethylhexyl)phthalate
87. Chrysene
88. Di-n- octyl phthalate
89. Benzo[b]fluoranthene
90. Benzo[k]fluoranthene
91. Benzo[a]pyrene
92. Perylene-D12 (IS)
93. Indeno[1,2,3-cd]pyrene
94. Dibenz[a,h]anthracene
95. Benzo[ghi]perylene
GC_EV1248
Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623) 8270 MegaMix (cat.# 31850) 8270 Benzidines mix (cat.# 31852) Benzoic acid (cat.# 31879) 1,4-Dioxane (cat.# 31853) Revised B/N surrogate mix (cat.# 31888) Acid surrogate mix (4/89 SOW) (cat.# 31063) Revised SV internal standard mix (cat.# 31886)
Methylene chloride 40 µg/mL (IS/SS 20 µg/mL) 1 µL split (split ratio 10:1) Premium 4 mm Precision liner w/wool (cat.# 23305.5) 270 °C 12 mL/min 70 °C (hold 1 min) to 285 °C at 28 °C/min to 305 °C at 3 °C/min to 320 °C at 30 °C/min (hold 1 min) He, constant flow 1.2 mL/min MS Scan 280 °C Quadrupole 270 °C 150 °C 70 eV 1.3 min DFTPP EI 35-550 amu 5.36 scans/sec Agilent 7890A GC & 5975C MSD
Download PDF relativo alle ricerche nella libreria dei cromatogrammi
,
,
,
,
,
,
,
,
,
,
,
,
,
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.