This site requires that Javascript be enabled. Please enable Javascript in your browser.
Semivolatile Organics by EPA Method 8270 on Rxi-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Peaks
1. 1,4-Dioxane
2. N-Nitrosodimethylamine
3. Pyridine
4. 2-Fluorophenol (SS)
5. Phenol-d6 (SS)
6. Phenol
7. Aniline
8. Bis(2-chloroethyl) ether
9. 2-Chlorophenol
10. 1,3-Dichlorobenzene
11. 1,4-dichlorobenzene-d4 (IS)
12. 1,4-Dichlorobenzene
13. Benzyl alcohol
14. 1,2-Dichlorobenzene
15. 2-Methylphenol
16. Bis(2-chloroisopropyl) ether
17. 4-Methylphenol/3-Methylphenol
18. N-Nitrosodi-N-propylamine
19. Hexachloroethane
20. Nitrobenzene-d5 (SS)
21. Nitrobenzene
22. Isophorone
23. 2-Nitrophenol
24. 2,4-Dimethylphenol
25. Benzoic acid
26. Bis(2-chloroethoxy)methane
27. 2,4-Dichlorophenol
28. 1,2,4-Trichlorobenzene
29. Naphthalene-d8 (SS)
30. Naphthalene
31. 4-Chloroaniline
32. Hexachlorobutadiene
33. 4-Chloro-3-methylphenol
34. 2-Methylnaphthalene
35. 1-Methylnaphthalene
36. Hexachlorocyclopentadiene
37. 2,4,6-Trichlorophenol
38. 2,4,5-Trichlorophenol
39. 2-Fluorobiphenyl (SS)
40. 2-Chloronaphthalene
41. 2-Nitroaniline
42. 1,4-Dinitrobenzene
43. Dimethyl phthalate
44. 1,3-Dinitrobenzene
45. 2,6-Dinitrotoluene
46. 1,2-Dinitrobenzene
Peaks
47. Acenaphthylene
48. 3-Nitroaniline
49. Acenaphthene-d10 (IS)
50. Acenaphthene
51. 2,4-Dinitrophenol
52. 4-Nitrophenol
53. 2,4-Dinitrotoluene
54. Dibenzofuran
55. 2,3,5,6-Tetrachlorophenol
56. 2,3,4,6-Tetrachlorophenol
57. Diethyl phthalate
58. 4-Chlorophenyl phenyl ether
59. Fluorene
60. 4-Nitroaniline
61. 4,6-Dinitro-2-methylphenol
62. N-Nitrosodiphenylamine (Diphenylamine)
63. 1,2-Diphenylhydrazine (as Azobenzene)
64. 2,4,6-Tribromophenol (SS)
65. 4-Bromophenyl phenyl ether
66. Hexachlorobenzene
67. Pentachlorophenol
68. Phenanthrene-d10 (IS)
69. Phenanthrene
70. Anthracene
71. Carbazole
72. di-n- Butyl phthalate
73. Fluoranthene
74. Benzidine
75. Pyrene-d10 (SS)
76. Pyrene
77. p- Terphenyl-d14 (SS)
78. 3,3'-Dimethylbenzidine
79. Butyl benzyl phthalate
80. Bis(2-ethylhexyl) adipate
81. 3,3'-Dichlorobenzidine
82. Benz[a]anthracene
83. Bis(2-ethylhexyl)phthalate
84. Chrysene-d12 (IS)
85. Chrysene
86. Di-n- octyl phthalate
87. Benzo[b]fluoranthene
88. Benzo[k]fluoranthene
89. Benzo[a]pyrene
90. Perylene-d12 (IS)
91. Dibenz[a,h]anthracene
92. Indeno[1,2,3-cd]pyrene
93. Benzo[ghi]perylene
C = Toluene
GC_EV01129
Rxi-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 13623) 8270 MegaMix (cat.# 31850) Benzoic acid (cat.# 31879) 8270 Benzidines Mix (cat.# 31852) Acid Surrogate Mix (4/89 SOW) (cat.# 31025) Revised B/N Surrogate Mix (cat.# 31887) 1,4-dioxane (cat.# 31853) SV Internal Standard Mix (cat.# 31206)
methylene chloride 10 ng on-column 1.0 µL pulsed splitless (hold 0.25 min) Singel Taper Splitless (4mm) w/Application-Specific Wool (cat.# 20798-231.1) 250 °C 25 psi (172.4kPa) 0.3 min 60 mL/min 40 °C (hold 1 min) to 280 °C at 25 °C/min to 320 °C at 5 °C/min (hold 1 min) He, constant flow 1.2 mL/min MS Scan 280 °C Quadrupole 250 °C DFTPP EI 35-550 amu Agilent 7890A GC & 5975C MSD
Download PDF relativo alle ricerche nella libreria dei cromatogrammi
Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.