Semivolatiles US EPA Method 8270 on Rtx-5Sil MS
Peaks tR (min)
1. N-Nitrosodimethylamine 3.38
2. Pyridine 3.37
3. Methyl methanesulfonate 4.53
4. 2-Fluorophenol (SS) 4.61
5. Ethyl methanesulfonate 5.16
6. Phenol 5.51
7. Phenol-d6- (SS) 5.50
8. Aniline 5.52
9. bis(2-chloroethyl)ether 5.58
10. 2-chlorophenol-d4 (SS) 5.60
11. 2-Chlorophenol 5.61
12. 1,3-Dichlorobenzene 5.73
13. 1,4-Dichlorobenzene-D4 (IS) 5.79
14. 1,4-Dichlorobenzene 5.80
15. Benzyl Alcohol 5.96
16. 1,2-Dichlorobenzene-D4 (SS) 5.94
17. 1,2-Dichlorobenzene 5.96
18. 2-Methylphenol 6.06
19. Bis(2-Chloroisopropyl)ether 6.06
20. 4-Methylphenol/3-Methylphenol 6.22
21. N-Nitrosodi-N-propylamine 6.24
22. Acetophenone 6.20
23. Hexachloroethane 6.25
24. Nitrobenzene-D5 (SS) 6.35
25. Nitrobenzene 6.37
26. Isophorone 6.59
27. 2,4-Dimethylphenol 6.70
28. 2-Nitrophenol 6.66
29. Benzoic acid 6.87
30. Bis(2-chloroethoxy)methane 6.79
31. 2,4-Dichlorophenol 6.89
32. 1,2,4-Trichlorobenzene 6.95
33. Naphthalene-D8 (IS) 7.00
34. Naphthalene 7.03
35. 2,6-Dichlorophenol 7.10
36. 4-Chloroaniline 7.12
37. Hexachloropropene 7.10
38. Hexachlorobutadiene 7.14
39. 4-Chloro-3-methylphenol 7.57
40. Isosafrole 7.61
41. 2-Methylnaphthalene 7.69
42. 1-Methylnaphthalene 7.79
43. Hexachlorocyclopentadiene 7.85
44. 1,2,4,5-Tetrachlorobenzene 7.86
45. 2,4,6-Trichlorophenol 7.98
46. 2,4,5-Trichlorophenol 8.02
47. 2-Fluorobiphenyl (SS) 8.05
48. Safrole 8.11
49. 2-Chloronaphthalene 8.17
50. 2-Nitroaniline 8.32
51. 1,4-Naphthoquinone 8.37
52. Dimethyl phthalate 8.48
53. 1,3-Dinitrobenzene 8.54
Peaks tR (min)
54. 2,6-Dinitrotoluene 8.56
55. Acenaphthylene 8.57
56. 3-Nitroaniline 8.68
57. Acenaphthene-d10 (IS) 8.71
58. Acenaphthene 8.74
59. 2,4-Dinitrophenol 8.82
60. 4-Nitrophenol 8.91
61. Pentachlorobenzene 8.89
62. 2,4-Dinitrotoluene 8.94
63. Dibenzofuran 8.91
64. 2,3,4,6-Tetrachlorophenol 9.05
65. Diethyl Phthalate 9.15
66. 4-Chlorophenyl phenyl ether 9.24
67. Fluorene 9.24
68. 4-Nitroaniline 9.30
69. 4,6-Dinitro-2-methylphenol 9.33
70. Diphenylamine 9.37
71. Azobenzene 9.39
72. 2,4,6-Tribromophenol (SS) 9.49
73. Phenacetin 9.70
74. 4-Bromophenyl phenyl ether 9.71
75. Hexachlorobenzene 9.80
76. Pentachlorophenol 9.99
77. Pentachloronitrobenzene 10.02
78. Dinoseb 10.16
79. Phenanthrene-D10 (IS) 10.16
80. Phenanthrene 10.18
81. Anthracene 10.23
82. di-n- Butyl phthalate 10.75
83. 4-nitroquinoline-1-oxide 11.04
84. Isodrin 11.29
85. Fluoranthene 11.50
86. Benzidine 11.71
87. Pyrene 11.80
88. Aramite 12.10
89. p- Terphenyl-d14 (SS)12.02
90. Chlorbenzilate 12.31
91. Butyl benzyl phthalate 12.84
92. Kepone 12.81
93. Bis(2-ethylhexyl)phthalate 13.99
94. Chrysene-D12 (IS) 13.87
95. 3,3'-Dichlorobenzidine 13.87
96. Benzo[a]anthracene (IS) 13.84
97. Chrysene 13.93
98. Di-n- octyl phthalate 15.51
99. Benzo[b]fluoranthene 16.29
100. Benzo[k]fluoranthene 16.35
101. Benzo[a]pyrene 17.07
102. Perylene-D12 (IS) 17.22
103. 3-Methylcholanthrene 17.98
104. Indeno[1,2,3-cd]pyrene 19.82
105. Dibenzo[a,h]anthracene 19.91
106. Benzo[ghi]perylene 20.44
GC_EV00545
Rtx-5Sil MS, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12723) Semivolatiles 8270 Standard
80 ng splitless 300 °C 40 °C (hold 2 min) to 245 °C at 25 °C/min to 330 °C at 6 °C/min (hold 5 min) He, constant flow 1.0 mL/min MS Scan 280 °C 35-550 amu