Parti e accessori per strumenti

Parti e accessori per strumenti

Products

Kit di manutenzione preventiva autocampionatore

per sistemi HPLC Agilent 1100, 1200

Kit PM pompa

per sistemi HPLC Agilent 1050, 1100, 1200

kits di manutenzione preventiva

per sistemi HPLC Waters e UPLC ACQUITY

Parti di ricambio strumento

per sistemi Waters ACQUITY e nanoACQUITY

Opti-Max Check Valves

  • Free-Turn housings can be removed with the tubing still attached, making maintenance fast while reducing fitting wear.
  • Rugged stainless steel cartridge bodies with ceramic ball and seat ensure longevity in harsh acetonitrile environments.
  • Every cartridge is tested to three bubbles of nitrogen/minute (industry standard is 12).
  • All balls and seats are individually matched.
  • Minimized ball travel distance delivers quicker seating for more accurate pump metering.

Visualizza le informazioni del prodotto

Metering Device Seal

for Agilent 1290 LC Samplers

Inlet Valve

for Agilent HPLC Systems

Passive Inlet Valve

for Agilent 1220, 1260 LC Systems

Line Filter

for Shimadzu LC Systems

Capillary Loop

for Agilent HPLC Systems

Diaphragm

for Shimadzu HPLC Systems

Gruppo tappo presa e guarnizioni dorate

per sistemi Agilent HPLC

Caps and seals shipped unassembled.

Note: Not compatible for use with Outlet Cap and Gold Seal Assembly Tool (cat.# 24989).

Visualizza le informazioni del prodotto

Guarnizione, disco dorato (uscita)

per sistemi Agilent HPLC

Note: Not compatible for use with Outlet Cap and Gold Seal Assembly Tool (cat.# 24989).

Visualizza le informazioni del prodotto

Kit di manutenzione pompa

per sistemi HPLC Agilent 1100, 1200

Filtro di aspirazione

per sistemi HPLC Shimadzu

Guarnizione di isolamento

per sistemi HPLC Agilent 1100, 1200

Gruppo frontale statore

per sistemi Agilent HPLC

Filtro iniettore solvente

per sistemi Agilent HPLC

Kit guarnizione pompa standard

per sistemi HPLC PerkinElmer

Guarnizioni pistone

per sistemi HPLC Thermo

Siringa, 500 µl

per sistemi HPLC Thermo

Nota: Le siringhe e gli aghi venduti da Restek sono destinati esclusivamente alla ricerca scientifica e all'uso in laboratorio e non sono destinati all'uso umano in vivo o su animali.

Visualizza le informazioni del prodotto

Gruppo siringa, 250 µl

per sistemi HPLC Thermo

Nota: Le siringhe e gli aghi venduti da Restek sono destinati esclusivamente alla ricerca scientifica e all'uso in laboratorio e non sono destinati all'uso umano in vivo o su animali.

Visualizza le informazioni del prodotto

Rondella Kel-F

per sistemi HPLC Thermo

Guarnizione di riserva

per sistemi HPLC Thermo

Pistone

per sistemi HPLC Thermo

Lubrificante iniettore

per sistemi Agilent HPLC

Lampade

per sistemi Agilent HPLC

Cartuccia iniettore attiva

per sistemi Agilent HPLC

Gruppo testa bottiglia

per sistemi Agilent HPLC

Tubo di collegamento

per sistemi Agilent HPLC

Tappo presa

per sistemi Agilent HPLC

PTFE Frits

per sistemi Agilent HPLC

Guarnizioni rotore

per sistemi Agilent HPLC

Gruppo ago

per sistemi Agilent HPLC

Nota: Le siringhe e gli aghi venduti da Restek sono destinati esclusivamente alla ricerca scientifica e all'uso in laboratorio e non sono destinati all'uso umano in vivo o su animali.

Visualizza le informazioni del prodotto

Gruppo supporto ago

per sistemi Agilent HPLC

Pistoni di zaffiro

per sistemi Agilent HPLC

Guarnizione per rondella

per sistemi Agilent HPLC

Kit lavaggio guarnizioni

per sistemi Agilent HPLC

Guarnizioni pistone

per sistemi Agilent HPLC

Setacci per valvola di scarico

per sistemi Agilent HPLC

Valvola di scarico a sfera

per sistemi Agilent HPLC

Gruppo guarnizione (ricostruito - con ago)

per autocampionatore Waters 717

Vite di compressione

per sistemi HPLC Waters

Kit guarnizione tubo di lavaggio

per sistemi HPLC Waters

Guarnizione frontale per rondella

per sistemi HPLC Waters

Ferrula

per sistemi HPLC Waters

Kit collettori iniettore

per sistemi HPLC Waters

Kit gruppo pistone di zaffiro

per sistemi HPLC Waters

Pistoni di zaffiro

per sistemi HPLC Waters

Kit parti guarnizioni inserto

per sistemi HPLC Waters

Kit guarnizione pistone testa

per sistemi HPLC Waters

Guarnizioni pistone

per sistemi HPLC Waters

Cartucce valvola di ritegno

per sistemi HPLC Waters

Lampade

per rilevatori Waters

Guarnizione di isolamento

per sistemi HPLC Waters: Stile Rheodyne

Guarnizione rotore Vespel

per sistemi HPLC Waters: Stile Rheodyne

Alberi pistone pompa HPLC di sostituzione ASI

per sistemi HPLC Agilent

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

Any time piston seals are replaced, the piston rod should be inspected with a 10x magnifier or microscope to ensure it does not have wear or scratches. Replace the rod if you observe any glazed regions or scratches.

Visualizza le informazioni del prodotto

Alberi pistone pompa HPLC di sostituzione ASI

per sistemi HPLC Waters

Buffer salts and metals from the HPLC system become imbedded on the surface of the piston seal and gradually wear the surface of the piston rod. Worn regions on the rod will quickly destroy the pump seals. In turn, the seal material gets trapped on the frit at the head of the column, which leads to increased system pressure and/or irregular or poor peak shape. As the piston continues to wear, a leak may develop at the pump.

Any time piston seals are replaced, the piston rod should be inspected with a 10x magnifier or microscope to ensure it does not have wear or scratches. Replace the rod if you observe any glazed regions or scratches.

Visualizza le informazioni del prodotto

Lampade al deuterio

per sistemi HPLC Shimadzu

Gruppo pistone

per sistemi HPLC Shimadzu

Siringa

per sistemi HPLC Shimadzu

Nota: Le siringhe e gli aghi venduti da Restek sono destinati esclusivamente alla ricerca scientifica e all'uso in laboratorio e non sono destinati all'uso umano in vivo o su animali.

Visualizza le informazioni del prodotto

Gruppo statore

per sistemi HPLC Shimadzu

Gruppo guarnizione rotore

per sistemi LC Shimadzu

Guarnizione ago

per sistemi HPLC Shimadzu

Pistoni di zaffiro

per sistemi HPLC Shimadzu

Guarnizione risciacquo pistone

per sistemi HPLC Shimadzu

Guarnizioni pistone

per sistemi LC Shimadzu

Valvole di ritegno in uscita

per sistemi LC Shimadzu

Valvole di ritegno in ingresso

per sistemi LC Shimadzu

Lampade al deuterio

per sistemi HPLC PerkinElmer

Ago

per sistemi HPLC PerkinElmer

Nota: Le siringhe e gli aghi venduti da Restek sono destinati esclusivamente alla ricerca scientifica e all'uso in laboratorio e non sono destinati all'uso umano in vivo o su animali.

Visualizza le informazioni del prodotto

Guarnizione a bassa pressione

per sistemi HPLC PerkinElmer

Guarnizione standard alta pressione

per sistemi HPLC PerkinElmer

Kit guarnizione ad alta pressione

per sistemi HPLC PerkinElmer

Valvola di ritegno in uscita

per sistemi HPLC PerkinElmer

Valvola di ritegno in ingresso

per sistemi HPLC PerkinElmer

Strumento gruppo tappo presa e guarnizioni dorate

per sistemi HPLC Agilent 1050, 1100

Easily install the gold seal into the outlet cap.

For use with Agilent 5001-3701 gold disk seal only. Not compatible with Restek cat.# 25889 and 25890 (Agilent 5067-4728).

Visualizza le informazioni del prodotto

Gruppi tubi capillari in acciaio inox

per sistemi Agilent HPLC

  • Precut, micro-polished tubing and pre-seated fittings for quick, easy maintenance of your Agilent HPLC systems.
  • Meet or exceed manufacturer's performance.

Visualizza le informazioni del prodotto

Guarnizioni pistone ASI

per sistemi Agilent HPLC

Over time the piston seal in every HPLC system becomes worn and must be replaced. Our piston seals are constructed of PTFE material with an additive that reduces their tendency to "cold flow" and improves their wear characteristics. PTFE seals are more resistant to any HPLC solvent than UHMWPE seals, but they are less wear-resistant and rugged. For Agilent 1050 and 1100 HPLC systems.

Visualizza le informazioni del prodotto