Ferrule

Products

Ferrule standard per raccordi da 1/16, 1/8 e 1/4"

Available in Vespel, graphite, or Vespel/graphite material.

Visualizza le informazioni del prodotto

Ferrule di riduzione

Available in graphite or Vespel/graphite material.

Visualizza le informazioni del prodotto

Ferrule cieche per raccordi da 1/16"

Vespel/Graphite Ferrules
  • VG2, 60% Vespel/40% graphite blend offers the best combination of sealing and ease of workability.
  • VG1, 85% Vespel/15% graphite blend offers equivalent composition to Agilent Vespel/graphite ferrules.
  • Seal with minimal torque, reusable, and preferred for vacuum and high-pressure uses.
  • Stable to 400 °C.

Visualizza le informazioni del prodotto

Ferrule per colonne microimpaccate

Standard—per raccordi da 1/16"

Ferrule per colonne microimpaccate

Compatto—per GC Agilent 5890/6890/6850/7890

Ferrule per colonne microimpaccate

Capillare—per raccordi a tipologia compressione da 1/16"

Ferrule (si adattano a colonne MXT con ID di 0,53 mm)

per GC Shimadzu 17A, 2010, 2014 e 2030

Swagelok Set dadi e ferrule (ottone e acciaio inox)

Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok fittings. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote.

Visualizza le informazioni del prodotto

Swagelok Ferrula anteriore (ottone e acciaio inox)

Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok fittings. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote.

Visualizza le informazioni del prodotto

Swagelok Ferrula posteriore (ottone e acciaio inox)

Restek is pleased to offer one of the premier lines of fittings available for chromatographers in the market today. We can supply the entire line of Swagelok fittings. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If you don't see the exact product you're looking for, please call us for a quote.

Visualizza le informazioni del prodotto

Parker Set dadi e ferrule (ottone e acciaio inox)

Parker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability.

Visualizza le informazioni del prodotto

Parker Ferrula anteriore (ottone e acciaio inox)

Parker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability.

Visualizza le informazioni del prodotto

Parker Ferrula posteriore (ottone e acciaio inox)

Parker’s (A-Lok) fittings are ideal for installing new equipment, modifying existing instrumentation, or replacing worn connections. Fittings are available in brass and stainless steel. Siltek/Sulfinert treated or Silcosteel-CR treated fittings are also available. If there is a particular Parker fitting that you are looking for and it is not listed here, please contact us to inquire about availability.

Visualizza le informazioni del prodotto

Ferrule Alumaseal

  • Aluminum construction—will not crack or fragment.
  • No retightening required after temperature cycles—excellent for GC-MS.
  • Eliminate out-gassing and make leak-tight seals for less detector noise.
  • Unique two-piece design permanently locks on fused silica tubing without causing breakage.
  • Will not stick in fittings, unlike Vespel or graphite ferrules.
  • Stable to 550 °C.
  • Use with any 1/16" compression-type fitting.

Visualizza le informazioni del prodotto

Ferrule in grafite per connettori "Y" SeCure

  • Preconditioned to minimize out-gassing.
  • High-purity, high-density graphite.
  • Stable to 450 °C.
  • No binders that can off-gas or adsorb analytes.
  • Smooth surface and clean edges.

Visualizza le informazioni del prodotto

Ferrule in grafite per connettori Vu2 Union

  • High-purity, high-density graphite.
  • Stable to 450 °C.
  • No binders that can off-gas or adsorb analytes.
  • Smooth surface and clean edges.

Visualizza le informazioni del prodotto

Ferrule di 5 mm

per GC Shimadzu 17A

  • For use with packed columns.
  • Graphite construction.

Visualizza le informazioni del prodotto

Ferrule PTFE

  • Upper temperature limit 250 °C.
  • 100% PTFE; completely inert.
  • One-piece design requires no back ferrule.

Visualizza le informazioni del prodotto

Valco Dadi e ferrule per connettori (1/16" acciaio inox)

Restek offers a selected line of Valco fittings for connecting fused silica or 1/16- or 1/8-inch metal tubing. Valco fittings have been designed for the specific demands of instrumentation and manufactured with the tight tolerances and premium quality that analysts require. If you don’t see the Valco fitting you need, please request special ordering information.

Visualizza le informazioni del prodotto

Valco Ferrule adattatore da 1/16"

Fused silica adaptor ferrules are made from Valcon polyimide, a unique, graphite-reinforced composite specially prepared to maximize mechanical stability at temperatures up to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

Visualizza le informazioni del prodotto

Ferrule incapsulate per raccordi a compressione da 1/16"

  • Reusable—will not deform and stick in fittings.
  • Less torque needed to seal ferrule.
  • Restek’s unique blend of graphite minimizes fragmentation and out-gassing.

Visualizza le informazioni del prodotto

Valco Ferrule adattatore da 1/32" (poliimmide Valcon)

Fused silica adaptor ferrules are made from Valcon polyimide, a unique, graphite-reinforced composite specially prepared to maximize mechanical stability at temperatures up to 350 °C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.

Visualizza le informazioni del prodotto

Ferrule a due fori per raccordi di tipo a compressione da 1/8 e 1/16"

  • Use 1/16-inch, two-hole ferrules with the 1/16-inch capillary inlet adaptor fitting kit (cat.# 27185).
  • Use 1/8-inch, two-hole ferrules with the 1/8-inch capillary inlet adaptor fitting kit (cat.# 20645).

Visualizza le informazioni del prodotto

Ferrule 3D/2 GRAPHPACK

GRAPHPACK technology provides a complete system that quickly and reliably makes a leak-tight, low-dead-volume connection. The central component is a metal-jacketed graphite ferrule—the ideal seal for GC applications.

Visualizza le informazioni del prodotto

Ferrule in grafite Vu-Union

  • Use with capillary Vu-Union and "Y" Vu-Union connectors.
  • 450°C maximum operating temperature.

Visualizza le informazioni del prodotto

Ferrule Vespel/grafite Vu-Union

  • Use with Vacuum Vu-Union connectors.
  • 60% Vespel/40% graphite.
  • 400 °C maximum operating temperature.

Visualizza le informazioni del prodotto

Valco Kit di rimozione ferrule

The tapered tools in this kit have teeth designed to grip and remove fused silica adaptor ferrules that have become stuck in the fitting detail. Each kit has two tools: one for removing 1/32-inch adaptor ferrules and one for removing 1/16-inch adaptor ferrules.

Visualizza le informazioni del prodotto

Alesatori getto/strumenti di rimozione ferrule in acciaio inox

A great tool for cleaning detector jets or removing stuck ferrules from other small orifices. Serrated design is optimal for removing silica deposits and other contaminants.

Visualizza le informazioni del prodotto

Estrattore di setti

  • Use hooked end for removing septa and O-rings; pointed end works well for removing stuck ferrules or debris.
  • Keep several on hand in your laboratory for other uses, too.

Visualizza le informazioni del prodotto

Lime ad ago appuntite 4"

These files can be used for many purposes. They are especially useful for removing ferrules that are lodged in injector or detector ports.

Visualizza le informazioni del prodotto

Set mini-trapano a mano

Drill ferrules to the proper ID in seconds! Includes three drills, for use with 0.25, 0.32, and 0.53 mm ID (0.4, 0.5, and 0.8 mm OD) capillary columns.

Visualizza le informazioni del prodotto