delim
delim
delim
Programma di laboratorio a contratto (CLP) Superfondo EPA

Programma di laboratorio a contratto (CLP) Superfondo EPA

Cerchi un composto specifico?

Scrivete il nome di un composto, un sinonimo, o CAS number.

Products

Kit VOA CAL2000 MegaMix CLP

Contains 1 mL each of these mixtures.
30632: CLP VOA CAL2000 MegaMix Standard
30216: vinyl acetate

Visualizza le informazioni del prodotto

Kit MegaMix B/N CLP 04.1

Contains 1 mL each of these mixtures.
31903: CLP 04.1 B/N MegaMix Standard, Revision 2
31902: CLP/SVOA Additions Mix

Visualizza le informazioni del prodotto

Kit MegaMix SVOA SOM01.1

Contains 1 mL each of these mixtures.
31900: SOM01.1 SVOA MegaMix Standard, Revised
31902: CLP/SVOA Additions Mix

Visualizza le informazioni del prodotto

Miscela standard pesticidi B con surrogati (13 componenti)

Components of these products are at 16x the contract-required quantitation level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

Visualizza le informazioni del prodotto

Miscela standard pesticidi A con surrogati (11 componenti)

Components of these products are at 16x the contract-required quantitation level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

Visualizza le informazioni del prodotto

Miscela di calibrazione GPC rivista (5 componenti)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

Visualizza le informazioni del prodotto

Miscela di calibrazione GPC CLP (5 componenti)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

Visualizza le informazioni del prodotto

Carbazolo

Note: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Kit di calibrazione composti semivolatili 3 (con benzidina)

Contains 1 mL each of these mixtures.
31007: SV Calibration Mix #1 (anilines)
31008: SV Calibration Mix #2 (phenols)
31009: SV Calibration Mix #3 (base neutrals)
31010: SV Calibration Mix #4 (base neutrals)
31011: SV Calibration Mix #5 (PAHs)
31013: SV Calibration Mix #7 (dichlorobenzenes)
31030: 605 Benzidines Calibration Mix (benzidine & 3,3'-dichlorobenzidine)

Visualizza le informazioni del prodotto

L/C VOA - Campione di controllo di laboratorio 2 (cloruro di vinile)

We prepare the L/C VOA Lab Control Sample in two parts. Sample #1 contains all compounds except vinyl chloride, because this compound is extremely volatile and must be replaced frequently. Sample #2 contains vinyl chloride.

Visualizza le informazioni del prodotto

VOA Kit N. 3 CLP 04.1

Contains 1 mL each of these mixtures.
30006: VOA Calibration Mix #1 (ketones)
30042: 502.2 Calibration Mix #1 (gases)
30456: CLP 04.1 VOA CAL2000 MegaMix Standard

Visualizza le informazioni del prodotto

Miscela aggiunta in matrice B/N (6 componenti)

  • Highest concentrations commercially available.
  • Reduces laboratory cost per sample extract.

Visualizza le informazioni del prodotto

Miscela surrogato acido (4/89 SOW) (3 componenti)

  • Highest concentrations commercially available.
  • Convenient 1 mL, 5 mL, and 10 mL package sizes.
  • Reduces laboratory cost per sample extract.

Visualizza le informazioni del prodotto

Miscela surrogato B/N (4/89 SOW) (3 componenti)

  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.
  • Convenient 1 mL, 5 mL, and 10 mL package sizes reduce cost per sample extract.

Visualizza le informazioni del prodotto

Miscela standard interno SV (6 componenti)

  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.

Visualizza le informazioni del prodotto

Soluzioni di aroclor

  • Aroclor standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Miscela di valutazione sistema pesticidi organoclorurati (2 componenti)

  • Designed for daily assessment of system performance.
  • Reveals active sites in the injection port and/or GC column.
  • Prepared in MTBE—low expansion volume helps minimize backflash.

Visualizza le informazioni del prodotto

Restek Domestic Customer Service

Oggetto

Messaggio

Nome e Cognome

Vostro indirizzo e-mail

Azienda

Indirizzo

Spam Block (Please leave this blank)
Aggiungi allegato, anche in Drag&Drop (facoltativo)
...

Campi Obbligatori

Grazie.

Il messaggio è stato inviato. La ricontatteremo non appena possibile.

Messaggio non inviato.

Siamo spiacenti, al momento non è stato possibile inviare il suo messaggio. Preghiamo di riprovare più tardi oppure di contattarci telefonicamente al numero +39 027610037

www.restek.com/Contact-Us