article_image

Mitigating Matrix Effects: Examination of Dilution, QuEChERS, and Calibration Strategies for LC-MS/MS Analysis of Pesticide Residues in Diverse Food Types

By Julie Kowalski, Sharon Lupo, and Jack Cochran

Table of Contents:

Introduction
Experimental
Results and Discussion
Conclusions

Abstract

Liquid chromatography tandem mass spectrometry (LC-MS/MS) is popular for monitoring pesticide residues in food. The increased selectivity and sensitivity of LC-MS/MS have impacted how multiresidue methods are performed, sometimes decreasing the need for rigorous sample preparation. However, this approach suffers from matrix effects causing poor data quality and difficult quantification. Matrix effects can be mitigated by sample preparation that reduces the concentration of coextracted matrix material or by experimental strategies like matrix-matched calibration that compensate for matrix effects. We considered these two aspects of multiresidue methods, sample preparation and calibration strategies, in order to determine recommendations that balanced data quality as well as time and financial investments.

We performed matrix effects studies investigating two approaches for reducing matrix interferences, QuEChERS sample preparation and dilution, in combination with the compensation strategy of matrix-matched calibration compared to solvent calibration. There are compromises with each method regarding time and financial resources. A variety of food types were tested including high water (celery), high pigment (kale), high fat (avocado), citrus (lime), and dry (brown rice flour) foods, with subsequent pesticide residue analysis by LC-MS/MS. Samples were fortified at high and low ppb levels with over 100 pesticides representing multiple classes.

We determined that with the easiest commodities, the dilution method and solvent-only calibration gave acceptable recovery values. However, for other commodities either a matrix-matched calibration curve and/or cleanup were needed to obtain good recovery values. The high carbohydrate and citrus commodities proved to be too difficult with the specific methods we tested here. In almost every case, use of matrix-matched calibration provided improvement.

Introduction

There are many challenges for chemists performing trace analysis like pesticide residues. Some challenges are associated with the diverse commodities that need to be tested and the large number of analytes. In recent years, the trend has been for analytical methods to become faster and simpler, but at the same time detect lower levels and test many analytes in one analysis (multiresidue methods).

Liquid chromatography tandem mass spectrometry (LC-MS/MS) is popular for this type of testing because it addresses some of these challenges and is amenable to many more pesticides than gas chromatographic techniques. Retention times, ion transitions, and transition ratios are used for pesticide identification and quantification. By monitoring ion transitions, tandem mass spectrometry increases selectivity by filtering specific ions. This selectivity removes noise, resulting in a large increase in the signal-to-noise ratio, thereby enhancing sensitivity.

Although tandem mass spectrometry is highly selective and sensitive, coeluting compounds can cause interferences at the LC-MS interface during electrospray ionization (ESI), which occurs before mass analysis and signal generation. Inconsistent ionization causes poor data quality and makes accurate quantification extremely difficult. We use the term “matrix effect” to discuss this ionization issue. The matrix effect of a compound is the change in ionization in solvent compared to ionization in matrix. Matrix coextractives can change the ionization efficiency of an analyte causing signal suppression or enhancement. Matrix effects must be considered to ensure acceptable quantitative results for any LC-MS/MS method.

Matrix effects can be compensated for by experimental design, for example, by employing labeled isotopic standards or matrix-matched calibration. Matrix-matched calibration is proven to be effective but adds time and cost to analysis. Also, it can be challenging to find commodities that do not contain pesticides that are target analytes. Efforts have been made to use one matrix-matched sample set for different commodities, but this has shown varying success [1,2,3].

Matrix compounds can be selectively removed by applying sample cleanup procedures. This lowers the concentrations of coextractives while maintaining the concentrations of target analytes, but it can be labor-intensive and costly. There is also the potential of losing analytes during sample processing. Common sample preparation techniques include liquid-liquid extraction, solid phase extraction, and the QuEChERS approach. QuEChERS has extraction and cleanup steps that remove matrix compounds, while maintaining analytes at initial concentrations. Another approach is to reduce matrix effects by directly diluting the sample. This decreases the matrix coextractives concentration, but it also decreases the concentration of target analytes. Higher dilutions reduce or eliminate matrix effects more successfully, but better and better sensitivity is required as dilution factors increase. Dilutions can range from 10 to 100-fold [4] and choosing the proper dilution factor depends on the concentrations of analytes and coextractives, as well as on chemical properties and instrument sensitivity. For example, 10 ppb is often used as a benchmark concentration because it is a common maximum residue limit for many pesticides in many foods. If we diluted the sample 50-fold, we need to detect and quantify pesticides at 0.2 ppb or 200 ppt (parts-per-trillion). The excellent sensitivity of tandem mass spectrometry can sometimes accommodate this inherent sensitivity challenge of dilution-based methods.

The dilution technique has been heavily promoted in recent years and sometimes endorsed as a universal method. It has been shown to be successful in many applications, including pesticides residue analysis. Dilution is attractive because it eliminates sample preparation and associated costs. However, pesticide residue testing involves a wide variety of food types as well as a large number of pesticides that vary in physiochemical properties and generally speaking a single method is not adequate to address this complexity. For that reason, it is important to evaluate the effectiveness of sample preparation techniques and define recommendations for applying different strategies.

We evaluated a variety of pesticides that are typical of multiresidue methods. We tested approximately 100 pesticides from different chemical classes including carbamate, organophosphorus, aniline, conazole, macrocyclic lactone, phenylurea, benzoylphenylurea, and strobilurin pesticides. We tested a variety of commodities representing different food types and ranging from easy to difficult. High water, low fat, low carbohydrate, and low pigment foods are considered the easiest commodities to analyze because their extracts do not contain the high amount of coextracted compounds that are more common with high fat, high carbohydrate, high pigment, and dry commodities.

Method performance was evaluated using matrix effect values, acceptable pesticide recovery values, and the number of pesticides detected. We fortified foods and processed samples according to QuEChERS and dilution methods. We then determined recovery values. Quantification was performed two ways, by using both a solvent calibration curve and a matrix-matched calibration curve. Calibration methods were evaluated by comparing recovery values. The experimental design yields four recovery value data sets for each commodity: dilution with solvent calibration, dilution with matrix-matched calibration, QuEChERS with solvent calibration, and QuEChERS with matrix-matched calibration. This allows assessment of sample preparation/calibration method combinations.

Experimental

Chemicals and Materials

All solvents were LC-MS grade and purchased from Fisher Scientific (Pittsburgh, PA). Formic acid was obtained from Sigma-Aldrich (Milwaukee, WI) and ammonium formate from Alfa Aesar (Ward Hill, MA). QuEChERS extraction and dispersive solid phase extraction (dSPE) tubes, as well as QuEChERS internal and quality control standards, were from Restek Corporation (Bellefonte, PA). The approximately 100 pesticide mix in acetonitrile was a custom standard that was combined with AOAC spike mix (cat.# 31999). Internal standards, atrazine-d5 and diazinon-d10, were purchased from Sigma-Aldrich (Milwaukee, WI). Food commodities were purchased at a local grocery store and included celery, kale, avocado, lime, and brown rice flour. Commodities were stored at -20 °C.

Sample Preparation

Commodity Selection

Celery is considered the easiest commodity with high water content, medium pigment, and low fat and carbohydrates. Kale represents a high water, high pigment commodity that produces an intensely colored extract. Lime is the representative citrus fruit. Although citrus fruits are known to be difficult for LC-MS/MS techniques, we included lime (with peel) to observe any differences among methods. Avocado represents the high fat category. Brown rice flour is a dry grain, which has very high carbohydrate content. Table I shows the nutritional composition of each food tested.

Table I:   Nutritional content for each commodity as grams per 100 grams of edible material.1

WaterSugarLipidsCarbohydratesProteinFiber
Celery9520312
Kale84na11032
Lime88201013
Avocado73115827
Brown rice flour12137775
1USDA National Nutrient Database for Standard Reference, http://ndb.nal.usda.gov/
(last modified: Dec 7, 2011).

Commodity Fortification

Frozen commodities were homogenized using a food processor, weighed, and fortified with pesticides at 10 and 500 µg/kg (ppb) levels. Internal standards atrazine-d5, diazinon-d10, and AOAC IS mix (cat.# 31963) were added at 250 ppb final extract concentration. Unfortified samples were prepared to determine incurred pesticides and produce matrix-matched standards.

AOAC QuEChERS Extraction

The AOAC QuEChERS extraction method was used for celery, kale, and lime. For these samples, 15 mL of acetonitrile with 1% acetic acid (v/v) was added to 15 g of fortified homogenized sample [5]. Q-sep AOAC buffering extraction salts (cat.# 26237) containing 6 g MgSO4, 1.5 g sodium acetate were added. At this point, lime samples were pH adjusted by adding 900 µL of a 5 N (or M, mol/L*) sodium hydroxide solution to the extraction tube. This pH adjustment was based on the EN method recommendation, but scaled for a 15 g sample [6]. Following 1 minute of manual shaking, samples were centrifuged for 5 minutes at 3,000 xg with a Q-sep 3000 centrifuge (cat.# 26230). The top acetonitrile layer was removed to a clean vial.

For dilution samples, the extract was diluted 20-fold with initial mobile phase, 90:10 (v:v) ratio of water with 4 mM ammonium formate and 0.1% formic acid to methanol with 4 mM ammonium formate and 0.1% formic acid.

*A 5 N sodium hydroxide solution is equivalent to a 5 M (molar, mol/L) solution.

Unbuffered QuEChERS Extraction

The original unbuffered extraction method was used for avocado and brown rice flour with adjustments for sample wetting [7]. For brown rice flour, 5 g of brown rice flour, 15 mL of deionized water, and 10 mL of acetonitrile were combined in a 50 mL centrifuge tube. The sample was vortexed briefly and shaken for one hour using a shaker table. For avocado, 3 mL water, 10 g of partially thawed homogenized avocado, and 10 mL of acetonitrile were added to a 50 mL centrifuge tube and shaken for one minute. The samples were centrifuged for 5 minutes at 3,000 xg with a Q-sep 3000 centrifuge (cat.# 26230). The top acetonitrile layer was removed to a clean vial.

For dilution LC-MS/MS analysis, the extract was diluted 20-fold with initial mobile phase, 90:10 (v:v) ratio of water with 4 mM ammonium formate and 0.1% formic acid to methanol with 4 mM ammonium formate and 0.1% formic acid.

QuEChERS Dispersive Solid Phase Extraction (dSPE) Cleanup

Restek Q-sep dSPE tubes were used and sorbent formulations were chosen based on commodity nutrient composition and preliminary experiments examining pigment removal. Table II shows the dSPE formulation, amount of extract processed, manual shake time, and specific dSPE formulation method and catalog number. Cleanup tubes contained one or more of three sorbents: primary secondary amine (PSA), octadecyl (C18), and graphitized carbon black (GCB). In addition to the contents listed in Table II, each dSPE tube contained 150 mg magnesium sulfate per mL extract processed. After the acetonitrile extract was added to the dSPE tube, the tube was shaken for the period specified in Table II. The samples were then centrifuged for 5 minutes at 3,000 xg. For LC-MS/MS analysis, the extract was diluted 10-fold with initial mobile phase, 90:10 (v:v) ratio of water with 4 mM ammonium formate and 0.1% formic acid to methanol with 4 mM ammonium formate and 0.1% formic acid.

Table II:   The dSPE sorbent formula and extract volume used during sample cleanup for each food are listed below. The shake time required, method associated with each formulation, and Restek catalog number are also presented.

dSPE Contents
PSA
(mg)
C18
(mg)
GCB
(mg)
Extract
(mL)
Shake
(min)
MethodCat.#
Celery257.512EN 1566226218
Kale30015062NA26126
Lime252.512EN 1566226217
Avocado505010.5AOAC 2007.0126125
Brown rice flour505010.5AOAC 2007.0126125

Solvent and Matrix-Matched Calibration Standards

Two calibration strategies commonly used for LC-MS/MS pesticide residue analysis are a solvent-only calibration curve and a matrix-matched calibration curve. The solvent curve uses analytes in a common solvent. The solvent calibration curve generated contained pesticides at various levels in the initial mobile phase of 90% water with 4 mM ammonium formate and 0.1% formic acid to 10% methanol with 4 mM ammonium formate and 0.1% formic acid (v/v). Solvent curves for the dilution method were generated daily with calibration levels of 0.25, 0.5, 1, 2, 10, 25, and 50 ppb with internal standard compounds at 12.5 ppb. Because only 5 g of brown rice flour was initially processed, the expected injection concentration of the 10 ppb spike samples was 0.25 ppb. Therefore, a 0.1 ppb calibration level was added for the brown rice flour samples. Solvent calibration curves for the QuEChERS method were also prepared daily with concentrations of 0.5, 1, 2, 10, 25, 50, and 75 ppb and internal standard compounds at 25 ppb. All solvent standards were made in 90% water with 4 mM ammonium formate and 0.1% formic acid to 10% methanol with 4 mM ammonium formate and 0.1% formic acid (v/v).

Dilution method matrix-matched calibration curves were produced by combining 50 µL matrix solution (pre-cleanup) with the pesticide stock standard solution and water with 4 mM ammonium formate and 0.1% formic acid totaling 1 mL and resulting in a 20-fold dilution of the matrix. This was done for calibration standards at 0.25, 0.5, 1, 2, 10, 25, and 50 ppb with internal standard compounds at 12.5 ppb. Again, a 0.1 ppb calibration standard was added for brown rice flour samples. The QuEChERS method matrix-matched curves combined 100 µL matrix solution (post cleanup), with pesticide stock solution and water with 4 mM ammonium formate and 0.1% formic acid totaling 1 mL and resulting in a 10-fold dilution of the matrix. Calibration standards included pesticides at 0.5, 1, 2, 10, 25, 50, and 75 ppb and internal standard compounds at 25 ppb.

LC-MS/MS Analysis

A Shimadzu UFLCXR LC (Columbia, MD) and Applied Biosystems/MDS SCIEX AB SCIEX API 4000 LC-MS/MS system with Turbo V source (Foster City, CA) were used for LC-MS/MS pesticide residue analysis. Testing was performed using a 100 mm x 2.1 mm, 3 µm Ultra Aqueous C18 column (Restek, cat.# 9178312) and 20 µL injections. The column was held at 50 °C. A mobile phase gradient of solvent A, water with 4 mM ammonium formate and 0.1% formic acid, and solvent B, methanol with 4 mM ammonium formate and 0.1% formic acid, and 0.5 mL/min flow rate were used. The mobile phase gradient is shown in Table III and includes a 3 minute re-equilibration step. Compounds were ionized by positive electrospray ionization. The interface parameters are as follows: interface temperature at 450 °C, ion spray voltage of 5.5 kV, curtain gas at 30 psi (206.8 kPa), ion source gas 1 at 40 psi (275.8 kPa), and ion source gas 2 at 45 psi (310.3 kPa).Two transitions were optimized for each compound and monitored in Scheduled MRM (sMRM) mode. The MRM window was 45 seconds and target scan time was 0.33 seconds. The optimized MRM transitions and retention times for each analyte are listed in Table IV and the optimized voltages can be found in Table V. Pesticide identification was based on retention time matching and MRM transition ratios.

Table III:   LC-MS/MS mobile phase gradient program.

Time (min)%A%B
09010
1.59010
63070
93070
100100
120100
12.019010
159010

Table IV:   LC-MS/MS MRM transitions and retention times for each analyte.

Component NameQ1/Q3 Transition 1, m/zQ1/Q3 Transition 2, m/ztR
(min)
Methamidophos 142.1 / 94.1142.1 / 112.21.27
Acephate 184.1 / 125.1184.1 / 95.11.78
propamocarb 189.2 / 102.0189.2 / 144.22.65
Omethoate 214.1 / 125.2214.1 / 155.12.94
Aldicarb sulfone 223.2 / 148.0223.2 / 76.23.45
Aldicarb sulfoxide 207.2 / 132.1207.2 / 89.13.71
Pymetrozine 218.1 / 105.0218.1 / 78.23.82
Oxamyl 237.1 / 71.9237.1 / 90.13.9
Methomyl 163.1 / 88.1163.1 / 106.24.02
Monocrotophos 224.1 / 127.1224.1 / 98.14.38
Dimethoate 230.1 / 125.2230.1 / 171.24.81
Mevinphos E 225.2 / 193.3225.2 / 127.24.99
Thiabendazole 202.2 / 175.0202.2 / 131.24.99
Imidacloprid 256.3 / 209.1256.3 / 175.25.02
Mevinphos Z 225.1 / 193.2225.1 / 127.15.43
Aldicarb 208.2 / 116.2208.2 / 89.15.55
Carbetamide 237.1 / 192.0237.1 / 118.15.73
Imazethapyr 290.1 / 245.2290.1 / 177.35.9
Thidiazuron 221.2 / 102.0221.2 / 128.15.93
Thiophanate methyl 343.2 / 151.1343.2 / 93.15.96
Propoxur 210.2 / 168.1210.2 / 111.25.99
Bendiocarb 224.1 / 109.2224.1 / 167.26.00
Dichlorvos 220.9 / 109.2220.9 / 95.06.01
Carbofuran 222.3 / 165.2222.3 / 123.16.09
Pirimicarb 239.2 / 72.2239.2 / 182.26.15
Carbaryl 202.3 / 127.1202.3 / 117.26.32
Imazalil 297.1 / 159.0297.1 / 173.16.40
Isoprocarb 194.3 / 95.2194.3 / 137.36.53
Metalaxyl 280.4 / 192.3280.4 / 160.26.72
Metalaxyl-M 280.4 / 220.3280.4 / 192.16.72
Atrazine 216.2 / 174.3216.2 / 132.16.75
Isoproturon 207.2 / 72.3207.2 / 134.36.86
Azinphos methyl 318.2 / 160.0318.2 / 132.16.96
Diuron 233.1 / 72.1233.1 / 160.06.97
Phosmet 318.1 / 160.2318.1 / 133.06.97
Demeton-O 259.0 / 89.1259.0 / 61.26.98
Demeton-S 259.2 / 88.9259.2 / 61.16.98
Nuarimol 315.0 / 252.1315.0 / 81.07.08
Propanil 218.2 / 162.0218.2 / 127.07.11
Azoxystrobin 404.3 / 372.3404.3 / 344.07.12
Malathion 331.1 / 127.1331.1 / 99.17.13
Methiocarb 226.1 / 169.1226.1 / 121.17.14
Chlorpropham 214.1 / 154.0214.1 / 126.17.20
Linuron 249.2 / 160.1249.2 / 182.17.20
Crotoxyphos 332.2 / 211.2332.2 / 167.27.21
Promecarb 208.8 / 109.2208.8 / 151.37.21
Propetamphos 282.1 / 138.0282.1 / 110.27.22
Boscalid 343.2 / 307.2343.2 / 140.07.25
Triadimefon 294.3 / 197.1294.3 / 69.27.26
Triadimenol 296.3 / 70.2296.3 / 227.17.35
Fenhexamid 302.1 / 97.1302.1 / 55.07.40
Myclobutanil 289.3 / 70.2289.3 / 124.97.43
Dichlofluanid 332.9 / 224.0332.9 / 123.17.44
Triazophos 314.1 / 162.0314.1 / 119.27.48
Alachlor 270.2 / 238.1270.2 / 162.27.60
Fenarimol 331.0 / 268.0331.0 / 81.07.61
Iprodione 330.3 / 245.2332.3 / 247.07.66
Ethoprop 243.1 / 131.0243.1 / 173.07.70
Parathion 292.1 / 236.0292.1 / 140.17.77
Fenamiphos 304.4 / 217.2304.4 / 202.07.83
Diflubenzuron 311.1 / 158.2311.1 / 141.17.85
Fenoxycarb 302.1 / 88.0302.1 / 116.17.87
Etaconazole-1 328.2 / 159.1328.2 / 123.07.89
Fenbuconazole 337.3 / 125.3337.3 / 70.37.89
Kresoxim methyl 314.2 / 115.9314.2 / 131.07.9
Tolyfluanid 364.0 / 238.0364.0 / 137.18.00
Etaconazole-2 328.3 / 159.2328.3 / 123.18.01
Fenthion 279.1 / 169.1279.1 / 105.18.06
Quinalphos 299.3 / 243.1299.3 / 163.28.07
Cyprodinil 226.1 / 93.3226.1 / 77.18.16
Tebuconazole 308.3 / 70.1308.3 / 125.18.24
Chlorfenvinphos 359.2 / 155.1359.2 / 99.28.32
Diazinon 305.2 / 169.3305.2 / 153.18.34
Pirimiphos methyl 306.1 / 164.3306.1 / 108.18.35
Phosalone 368.1 / 182.1368.1 / 138.08.38
Coumaphos 363.1 / 227.2363.1 / 211.18.46
Propiconazole-1 342.3 / 159.0342.3 / 69.38.60
Pyraclostrobin 388.0 / 164.2388.0 / 194.38.61
Chlorpyrifos methyl 323.9 / 125.0323.9 / 291.88.72
Propiconazole-2 342.4 / 159.1342.4 / 69.48.77
Dialifos 394.3 / 208.0394.3 / 187.08.81
Prochloraz 376.1 / 308.1376.1 / 266.09.01
Indoxacarb 528.6 / 218.0528.6 / 150.29.04
Trifloxystrobin 409.4 / 186.0409.4 / 145.19.18
Spinosyn A 733.1 / 142.4733.1 / 98.49.58
difenoconazole-1 406.3 / 251.1408.2 / 253.19.60
Triflumizole 346.2 / 278.2346.2 / 73.19.79
Difenoconazole-2 406.4 / 251.2408.3 / 253.29.85
Ethion 385.3 / 199.0385.3 / 171.010.20
Spinosyn D 746.8 / 142.4746.8 / 98.310.38
Chlorpyrifos 350.0 / 198.0350.0 / 97.010.40
Pendimethalin 282.3 / 212.2282.3 / 194.310.47
Emamectin B1a Benzoate 887.2 / 158.3887.2 / 126.310.48
Propargite 368.4 / 175.1368.4 / 231.210.61
Fenpropathrin 350.3 / 125.0350.3 / 97.410.67
Flufenoxuron 489.5 / 158.2489.5 / 141.110.72
Lambda-cyhalothrin 467.4 / 225.1467.4 / 181.010.72
Deltamethrin 523.3 / 280.9523.3 / 181.010.78
trans-Permethrin 408.4 / 183.3408.4 / 153.210.90
Leptophos 413.2 / 171.0413.2 / 77.110.92
cis-Permethrin 408.5 / 183.1408.5 / 153.210.95
Bifenthrin 440.3 / 181.2440.3 / 166.210.98

Table V:   LC-MS/MS optimized voltages for MRM mode. Voltages for first and second transitions are designated by 1 and 2, respectively.

Component NameDeclustering
Potential
(DP), V
Entrance
Potential
(EP), V
Collision
Energy
(CE), V
Collision Cell Exit
Potential
(CXP), V
Methamidophos 15711206
Methamidophos 25711178
Acephate 1535257
Acephate 2535326
Propamocarb 16110258
Propamocarb 248111911
Omethoate 1555317
Omethoate 25552210
Aldicarb sulfone 17151411
Aldicarb sulfone 27151214
Aldicarb sulfoxide 15831010
Aldicarb sulfoxide 2583205
Pymetrozine 16610296
Pymetrozine 26610534
Oxamyl 1345206
Oxamyl 2345126
Methomyl 1335136
Methomyl 2335157
Monocrotophos 1605216
Monocrotophos 2605186
Dimethoate 15611296
Dimethoate 256112111
Mevinphos E 1595208
Mevinphos E 2595106
Imidacloprid 16211216
Imidacloprid 262112510
Thiabendazole 19193611
Thiabendazole 2919479
Mevinphos Z 1595106
Mevinphos Z 2595208
Aldicarb 1 305119
Aldicarb 2305225
Carbetamide 156101312
Carbetamide 256101910
Atrazine d5 (IS) 1 64102611
Atrazine d5 (IS) 26410365
Imazethapyr 17753015
Imazethapyr 27753810
Thidiazuron 15211226
Thidiazuron 25211227
Thiophanate methyl 169112811
Thiophanate methyl 26911686
Propoxur 1565218
Propoxur 25651211
Bendiocarb 160112534
Bendiocarb 2601111015
Dichlorvos 1745277
Dichlorvos 2745467
Carbofuran 164101711
Carbofuran 26410308
Pirimicarb 14810325
Pirimicarb 248102310
Carbaryl 157153711
Carbaryl 25715349
Imazalil 179113011
Imazalil 279113511
Isoprocarb 16210226
Isoprocarb 262101411
Metalaxyl-M 16011206
Metalaxyl-M 260112614
Metalaxyl 1545415
Metalaxyl 25456315
Atrazine 17292510
Atrazine 2729328
Isoproturon 1685315
Isoproturon 2685317
Phosmet 16441712
Phosmet 26445010
Demeton-S 1505166
Demeton-S 2505487
Demeton-O 1405146
Demeton-O 2405476
Diuron 17410445
Diuron 274103612
Azinphos methyl 15751111
Azinphos methyl 25752110
Nuarimol 181103116
Nuarimol 281104514
Azoxystrobin 15810209
Azoxystrobin 25810349
Propanil 166152311
Propanil 26615369
Malathion 16315197
Malathion 26315337
Methiocarb 16151510
Methiocarb 2615278
Promecarb 1635229
Promecarb 26351411
Crotoxyphos 1344136
Crotoxyphos 23442111
Chlorpropham 15452511
Chlorpropham 2545358
Linuron 169102511
Linuron 269102310
Propetamphos 16062311
Propetamphos 2606418
Boscalid 198102811
Boscalid 298102711
Triadimefon 15911226
Triadimefon 25911326
Triadimenol 1424265
Triadimenol 2424146
Fenhexamid 18110356
Fenhexamid 281107110
Myclobutanil 16511365
Myclobutanil 26511399
Dichlofluanid 17041615
Dichlofluanid 27044415
Triazophos 17692611
Triazophos 2769509
Alachlor 14651215
Alachlor 24652811
Fenarimol 16110314
Fenarimol 261104915
Diazinon d10 (IS) 174103111
Diazinon d10 (IS) 274103211
Iprodione 1824216
Iprodione 2824317
Ethoprop 164112111
Ethoprop 26411299
Parathion 17042215
Parathion 27043310
Parathion d10 17444928
Parathion d10 27444928
Fenamiphos 1825316
Fenamiphos 2825476
Diflubenzuron 17042210
Diflubenzuron 2704468
Fenoxycarb 16610316
Fenoxycarb 26610178
Fenbuconazole 17810386
Fenbuconazole 27810435
Kresoxim methyl 16610338
Kresoxim methyl 26610196
Etaconazole (isomer 1) 193103510
Etaconazole (isomer 1) 29310759
Etaconazole (isomer 2) 1 93103510
Etaconazole (isomer 2) 2 9310759
Tolyfluanid 14610398
Tolyfluanid 246101914
Fenthion 171102511
Fenthion 27110347
Quinalphos 156112415
Quinalphos 256113411
Cyprodinil 19211495
Cyprodinil 292116114
Tebuconazole 17511466
Tebuconazole 27511487
Chlorfenvinphos 17851911
Chlorfenvinphos 2785447
Diazinon 158103111
Diazinon 258102812
Phosalone 1789209
Phosalone 27894111
Pirimiphos methyl 175113111
Pirimiphos methyl 27511439
Coumaphos 19211356
Coumaphos 2130105212
Pyraclostrobin 14610186
Pyraclostrobin 246102611
Propiconazole (isomer 1) 18153711
Propiconazole (isomer 1) 2815375
Propiconazole (isomer 2) 18153711
Propiconazole (isomer 2) 2815375
Chlorpyrifos Methyl 1745289
Chlorpyrifos Methyl 27452218
Dialifos 1715127
Dialifos 2715206
Indoxacarb 190113314
Indoxacarb 290113411
Prochloraz 151111711
Prochloraz 251112418
Trifloxystrobin 15662213
Trifloxystrobin 25666111
Difenoconazole (isomer 1) 18611346
Difenoconazole (isomer 1) 27610334
Spinosyn A 1111114411
Spinosyn A 211111937
Triflumizole 15351512
Triflumizole 2535265
Difenoconazole (isomer 2) 18611346
Difenoconazole (isomer 2) 27610334
Ethion 1715156
Ethion 27152211
Spinosyn D 1112114111
Spinosyn D 211211937
Chlorpyrifos 17110456
Chlorpyrifos 271102312
Pendimethalin 1454166
Pendimethalin 2454267
Emamectin B1a Benzoate 1 12755011
Emamectin B1a Benzoate 21275626
Propargite 1615157
Propargite 26152311
Fenpropathrin 1103101711
Fenpropathrin 210310445
Lambda-cyhalothrin 1595226
Lambda-cyhalothrin 25954915
Flufenoxuron 19152711
Flufenoxuron 29156512
Deltamethrin 15642219
Deltamethrin 2130105212
trans-Permethrin 15010226
trans-Permethrin 250106111
Leptophos 185113213
Leptophos 28511776
cis-Permethrin 149102713
cis-Permethrin 249106111
Bifenthrin 1535189
Bifenthrin 25355911

Determination of Matrix Effects

Matrix effect values were determined for each pesticide in each commodity. Data were generated from the solvent and matrix-matched calibration curves discussed previously. Matrix effect values were calculated by comparing the ratio of the solvent curve slope to the matrix-matched curve slope. Equation 1 shows the calculation used to determine matrix effect. Values above 100% indicate enhanced ionization in matrix and values below 100% define ion signal suppression due to matrix.

Equation 1

Pesticide Percent Recovery Determination

Fortified samples at two levels, 10 and 500 µg/kg (ppb), were prepared for both the QuEChERS method and the dilution method. Atrazine-d5 was used as an internal standard. Quantification was performed two ways: one way used a solvent calibration curve and the other way used a matrix-matched calibration curve. Calculated concentrations were compared to the expected concentration, assuming 100% recovery. For each pesticide there is a set of four recovery values per fortification level: two recovery values for the QuEChERS method and two values for the dilution method. These values are based on pesticide quantification using a solvent curve and a matrix-matched curve. The four percent recovery categories will be abbreviated as shown in Table VI.

Table VI:   Abbreviations for the sample preparation and calibration method combinations.

AbbreviationSample Preparation MethodCalibration Method
Q/SolQuEChERSsolvent calibration curve
Q/MMQuEChERSmatrix-matched calibration curve
D/Soldilutionsolvent calibration curve
D/MMdilutionmatrix-matched calibration curve

Results and Discussion

LC-MS/MS Analysis

Figure 1 shows a chromatogram of kale extract processed with the QuEChERS method. This is representative of the chromatograms produced in this work. Analytes eluted in 11 minutes followed by a short high-organic rinse and an equilibration step. The high-organic rinse was important in helping to maintain the column and also in avoiding matrix carryover into the next sample. Elution of remaining matrix material during a subsequent analysis can cause unexpected matrix effects. There is evidence that late eluting matrix compounds in a reverse phase HPLC analysis can cause significant ion suppression [2].

Retention times were an integral part of pesticide identifications and were used to produce the scheduled MRM program. For these reasons, retention time reproducibility is extremely important. We tested approximately 380 samples; each sample tracked 204 MRM transitions resulting in 77,520 MRM transitions. Only four transitions, or 0.005%, shifted and all of these were isomers that could be manually integrated and reported as one peak. Early eluting polar pesticides typically are difficult to analyze on C18 columns and usually are characterized by little or no retention and poor peak shape. However, we obtained excellent results using an Ultra Aqueous C18 column. We tested polar pesticides methamidophos, acephate, propamocarb, and omethoate using an Ultra Aqueous C18 column (100 mm x 2.1 mm, 3 µm). This column is a polar modified bonded C18 stationary phase, meaning it can interact with polar and nonpolar compounds. This resulted in significant retention and good peak shapes for these early-eluting polar pesticides. Also, the remaining analytes were distributed across the elution window. This can help ensure a proper scan rate for scheduled MRM methods with many analytes.

Figure 1:   Chromatogram of QuEChERS extract of kale fortified with pesticides. View larger

PeakstR (min)MRM 1MRM 2
1.Methamidophos1.27142.1 / 94.1142.1 / 112.2
2.Acephate1.78184.1 / 125.1184.1 / 95.1
3.Propamocarb2.65189.2 / 102.0189.2 / 144.2
4.Omethoate2.94214.1 / 125.2214.1 / 155.1
5.Aldicarb sulfone3.45223.2 / 148.0223.2 / 76.2
6.Aldicarb sulfoxide3.71207.2 / 132.1207.2 / 89.1
7.Pymetrozine3.82218.1 / 105.0218.1 / 78.2
8.Oxamyl3.90237.1 / 71.9237.1 / 90.1
9.Methomyl4.02163.1 / 88.1163.1 / 106.2
10.Monocrotophos4.38224.1 / 127.1224.1 / 98.1
11.Dimethoate4.81230.1 / 125.2230.1 / 171.2
12.Mevinphos E4.99225.2 / 193.3225.2 / 127.2
13.Thiabendazole4.99202.2 / 175.0202.2 / 131.2
14.Imidacloprid5.02256.3 / 209.1256.3 / 175.2
15.Mevinphos Z5.43225.1 / 193.2225.1 / 127.1
16.Aldicarb5.55208.2 / 116.2208.2 / 89.1
17.Carbetamide5.73237.1 / 192.0237.1 / 118.1
18.Imazethapyr5.90290.1 / 245.2290.1 / 177.3
19.Thidiazuron5.93221.2 / 102.0221.2 / 128.1
20.Thiophanate methyl5.96343.2 / 151.1343.2 / 93.1
21.Propoxur5.99210.2 / 168.1210.2 / 111.2
22.Bendiocarb6.00224.1 / 109.2224.1 / 167.2
23.Dichlorvos6.01220.9 / 109.2220.9 / 95.0
24.Carbofuran6.09222.3 / 165.2222.3 / 123.1
25.Pirimicarb6.15239.2 / 72.2239.2 / 182.2
26.Carbaryl6.32202.3 / 127.1202.3 / 117.2
27.Imazalil6.40297.1 / 159.0297.1 / 173.1
28.Isoprocarb6.53194.3 / 95.2194.3 / 137.3
29.Metalaxyl6.72280.4 / 192.3280.4 / 160.2
30.Metalaxyl-m6.72280.4 / 220.3280.4 / 192.1
31.Atrazine6.75216.2 / 174.3216.2 / 132.1
32.Atrazine-d5 (IS)6.77221.1 / 179.0221.1 / 101.2
33.Isoproturon6.86207.2 / 72.3207.2 / 134.3
34.Azinphos-methyl6.96318.2 / 160.0318.2 / 132.1
35.Diuron6.97233.1 / 72.1233.1 / 160.0
36.Phosmet6.97318.1 / 160.2318.1 / 133.0
37.Demeton-O6.98259.0 / 89.1259.0 / 61.2
38.Demeton-S6.98259.2 / 88.9259.2 / 61.1
39.Nuarimol7.08315.0 / 252.1315.0 / 81.0
40.Propanil7.11218.2 / 162.0218.2 / 127.0
41.Azoxystrobin7.12404.3 / 372.3404.3 / 344.0
42.Malathion7.13331.1 / 127.1331.1 / 99.1
43.Methiocarb7.14226.1 / 169.1226.1 / 121.1
44.Chlorpropham7.20214.1 / 154.0214.1 / 126.1
45.Linuron7.20249.2 / 160.1249.2 / 182.1
46.Crotoxyphos7.21332.2 / 211.2332.2 / 167.2
47.Promecarb7.21208.8 / 109.2208.8 / 151.3
48.Propetamphos7.22282.1 / 138.0282.1 / 110.2
49.Boscalid7.25343.2 / 307.2343.2 / 140.0
50.Triadimefon7.26294.3 / 197.1294.3 / 69.2
51.Triadimenol7.35296.3 / 70.2296.3 / 227.1
52.Fenhexamid7.40302.1 / 97.1302.1 / 55.0
53.Myclobutanil7.43289.3 / 70.2289.3 / 124.9
54.Dichlofluanid7.44332.9 / 224.0332.9 / 123.1
55.Triazophos7.48314.1 / 162.0314.1 / 119.2
56.Alachlor7.60270.2 / 238.1270.2 / 162.2
57.Fenarimol7.61331.0 / 268.0331.0 / 81.0
58.Iprodione7.66330.3 / 245.2332.3 / 247.0
59.Ethoprop7.70243.1 / 131.0243.1 / 173.0
60.Parathion7.77292.1 / 236.0292.1 / 140.1
61.Fenamiphos7.83304.4 / 217.2304.4 / 202.0
62.Diflubenzuron7.85311.1 / 158.2311.1 / 141.1
63.Fenoxycarb7.87302.1 / 88.0302.1 / 116.1
64.Etaconazole isomer 17.89328.2 / 159.1328.2 / 123.0
65.Fenbuconazole7.89337.3 / 125.3337.3 / 70.3
66.Kresoxim-methyl7.90314.2 / 115.9314.2 / 131.0
67.Tolyfluanid8.00364.0 / 238.0364.0 / 137.1
68.Etaconazole isomer 28.01328.3 / 159.2328.3 / 123.1
69.Fenthion8.06279.1 / 169.1279.1 / 105.1
70.Quinalphos8.07299.3 / 243.1299.3 / 163.2
71.Cyprodinil8.16226.1 / 93.3226.1 / 77.1
72.Tebuconazole8.24308.3 / 70.1308.3 / 125.1
73.Chlorfenvinphos8.32359.2 / 155.1359.2 / 99.2
74.Diazinon8.34305.2 / 169.3305.2 / 153.1
75.Pirimiphos methyl8.35306.1 / 164.3306.1 / 108.1
76.Phosalone8.38368.1 / 182.1368.1 / 138.0
77.Diazinon-d10 (IS)8.39315.3 / 170.1315.3 / 154.1
78.Coumaphos8.46363.1 / 227.2363.1 / 211.1
79.Propiconazole isomer 18.60342.3 / 159.0342.3 / 69.3
80.Pyraclostrobin8.61388.0 / 164.2388.0 / 194.3
81.Chlorpyrifos methyl8.72323.9 / 125.0323.9 / 291.8
82.Propiconazole isomer 28.77342.4 / 159.1342.4 / 69.4
83.Dialifos8.81394.3 / 208.0394.3 / 187.0
84.Prochloraz9.01376.1 / 308.1376.1 / 266.0
85.Indoxacarb9.04528.6 / 218.0528.6 / 150.2
86.Trifloxystrobin9.18409.4 / 186.0409.4 / 145.1
87.Spinosyn A9.58733.1 / 142.4733.1 / 98.4
88.Difenoconazole isomer 19.60406.3 / 251.1408.2 / 253.1
89.Triflumizole9.79346.2 / 278.2346.2 / 73.1
90.Difenoconazole isomer 29.85406.4 / 251.2408.3 / 253.2
91.Ethion10.20385.3 / 199.0385.3 / 171.0
92.Spinosyn D10.38746.8 / 142.4746.8 / 98.3
93.Chlorpyrifos10.40350.0 / 198.0350.0 / 97.0
94.Pendimethalin10.47282.3 / 212.2282.3 / 194.3
95.Emamectin B1a benzoate10.48887.2 / 158.3887.2 / 126.3
96.Propargite10.61368.4 / 175.1368.4 / 231.2
97.Fenpropathrin10.67350.3 / 125.0350.3 / 97.4
98.Flufenoxuron10.72489.5 / 158.2489.5 / 141.1
99.Lambda cyhalothrin10.72467.4 / 225.1467.4 / 181.0
100.Deltamethrin10.78523.3 / 280.9523.3 / 181.0
101.trans-Permethrin10.90408.4 / 183.3408.4 / 153.2
102.Leptophos10.92413.2 / 171.0413.2 / 77.1
103.cis-Permethrin10.95408.5 / 183.1408.5 / 153.2
104.Bifenthrin10.98440.3 / 181.2440.3 / 166.2
Isomers were designated 1 or 2 by elution order
Pesticide Residue Analysis in Kale by LC-MS/MS on Ultra Aqueous C18
LC_FF0516
ColumnUltra Aqueous C18 (cat.# 9178312)
Dimensions:100 mm x 2.1 mm ID
Particle Size:3 µm
Pore Size:100 Å
Temp.:50 °C
SampleKale extract diluted 10x in mobile phase A
Diluent:Mobile phase A
Conc.:10 ng/mL
Inj. Vol.:20 µL
Mobile Phase
A:Water + 0.1% formic acid + 4 mM ammonium formate
B:Methanol + 0.1% formic acid + 4 mM ammonium formate
Time (min)Flow (mL/min)%A%B
0.000.59010
1.500.59010
6.000.53070
9.000.53070
10.000.50100
12.000.50100
12.010.59010
15.000.59010
DetectorABSCIEX MS/MS
Model #:API 4000
Ion Source:TurboIonSpray®
Ion Mode:ESI+
Ion Spray Voltage:5.5 kV
Curtain Gas:30 psi (206.8 kPa)
Gas 1:40 psi (275.8 kPa)
Gas 2:45 psi (310.3 kPa)
CAD:10 psi (68.9 kPa)
Source Temp.:450 °C
Mode:Scheduled MRM
MRM Detection Window:45 sec
Target Scan Time:0.33 sec
InstrumentAPI LC-MS/MS
NotesThe AOAC QuEChERS method was used. 15 mL of acetonitrile with 1% acetic acid (v/v) was added to 15 g of fortified homogenized kale. Q-sep AOAC buffering extraction salts (cat.# 26237) containing 6 g MgSO4 and 1.5 g sodium acetate were added. Following 1 minute of manual shaking, samples were centrifuged for 5 minutes at 3,000 U/min with a Q-sep 3000 centrifuge (cat.# 26230). The top acetonitrile layer was removed to a clean vial. A Restek Q-sep dSPE tube, cat.# 26126, containing 300 mg PSA, 150 mg GCB, and 900 mg MgSO4 was used to process 6 mL of kale extract. The tube was shaken for 2 minutes and centrifuged for 5 minutes at 3,000 U/min. The sample was diluted 10-fold in mobile phase A before injection.

Matrix Effects Interpretation

The matrix effect for each compound was calculated as described by Equation 1 above. If we assume that the slopes of the solvent calibration curve and the matrix-matched curve are equal, then no matrix effect is present and the slope ratio is 1, meaning the signal of a compound in matrix and in solvent is exactly the same. A matrix effect value above 100% indicates signal enhancement when the analyte is tested in matrix. When the value is below 100% this means that the signal of an analyte in matrix is lower or suppressed compared to analyte in solvent.

We illustrate total matrix effects by plotting the calculated matrix effect minus 100 for each compound ordered by increasing retention time. These plots help identify matrix effect trends, like overall suppression or enhancement of a specific commodity or an association between retention time and matrix effects. These matrix effect plots were generated for samples processed by QuEChERS and dilution methods and can be used to compare trends. For example, the plots for celery in Figure 2 show that the dilution method tended to produce signal enhancement, while celery processed with QuEChERS tended to show signal suppression. However, both methods produce samples that show signal enhancement at the end of the chromatogram.

Figure 2:   Matrix effect for celery plotted in retention time order. The dilution method tended to produce signal enhancement, whereas the QuEChERS method usually resulted in signal suppression.

Matrix effect for celery plotted in retention time order.

More drastic matrix effects at specific points in the chromatogram can indicate what type of coextracted compounds might be in the sample. For example, strong matrix effects at the end of a reverse phase chromatographic analysis indicate that hydrophobic compounds, like lipids, might be causing ionization problems. If we look at the plots for high fat avocado in Figure 3, we see ion suppression at the end of the elution window for samples produced by both sample treatments. It is reasonable to conclude that lipid content remains in both samples.

Figure 3:   Matrix effect for avocado plotted in retention time order. Signal suppression is evident for late eluting compounds for both dilution and QuEChERS samples.

Matrix effect for avocado plotted in retention time order.

Corresponding plots for kale and rice show the QuEChERS method was able to mitigate matrix effects for some portions of the chromatogram. Signal enhancement at the beginning and end of kale chromatograms is decreased when the sample is treated with the QuEChERS method (Figure 4). The brown rice plots, also in Figure 4, demonstrate a clear example of matrix effect reduction with the QuEChERS sample for many pesticides, especially for early and late eluting pesticides as shown by the U-shaped plot of the dilution method. Lime plots did not show any clear trends.

Figure 4:   Matrix effects plots for kale (top) and brown rice flour (bottom). For many pesticides, the QuEChERS method reduced matrix effects.

Matrix effects plots for kale (top) and brown rice flour (bottom).

Matrix Effects Evaluation

Matrix effect values from 80-120% are considered suitable values indicating minor matrix effects. The range is considered acceptable by many people testing for pesticide residues. Often, this 100±20% range is used as a cutoff value to justify using solvent calibration as opposed to matrix-matched standards. We evaluated the different testing strategies by comparing the percent of compounds tested that fell within ± 20% of the solvent curve values (Figure 5). The total number of compounds is 102, but it is adjusted here for incurred pesticides. Incurred pesticides determined by either QuEChERS or dilution methods were removed from both data sets. This ranged from three incurred pesticides for brown rice flour, to fifteen incurred pesticides in celery. Commodities are listed in order of increasing difficulty from left to right in Figure 5.

Figure 5:   Comparison of the percent of analytes that have matrix effects within 80-120% by commodity and sample preparation method.

Comparison of the percent of analytes that have matrix effects within 80-120% by commodity and sample preparation method.

Celery has high water, intermediate color, and is low in fat. The performances of QuEChERS and dilution methods are almost identical, 92% and 90% matrix effects, respectively. Both strategies for decreasing the concentration of coextracted material are successful. For celery, the dilution method saved time and eliminated the potential loss of analytes by sample cleanup.

Figure 6:   Preparation of kale samples for analysis. From left to right, sample layers separated in extraction tube, extract (solvent layer) removed to a clean vial, extract treated with dSPE cleanup, post-cleanup extract diluted 10x (QuEChERS sample for analysis), and pre-cleanup extract diluted 20x (dilution sample for analysis).

Preparation of kale samples for analysis.

As shown in Figure 6, the initial QuEChERS extraction step was used for both the QuEChERS and the dilution methods. The dark top layer is the acetonitrile extract that was prepared two ways for analysis. For the dilution sample, this extract was diluted 20-fold and analyzed; whereas for the QuEChERS method, this extract was further processed by dispersive solid phase extraction and then diluted 10-fold and analyzed. Much of the pigment was removed by GCB during dSPE cleanup; however, even at this level of dilution significant pigment remains. This impacts the cleanliness of the LC-MS/MS interface requiring more frequent cleaning to maintain the same level of data quality. Based on Figure 5, the QuEChERS and dilution methods performed similarly well for kale with respect to analyte matrix effects. The QuEChERS method resulted in 91% of analytes having low matrix effects compared to the dilution method that achieved low matrix effects for 80% of analytes. That is a relatively small difference of about ten compounds. The QuEChERS method provides a slight advantage in minimizing matrix effects, which in general can help increase the time between interface cleanings. The dilution method performs well and requires less sample preparation time and expense. We estimate that the QuEChERS method added about one and a half hours to total processing time.

Avocado is more challenging chiefly because of its high fat content and lower water content. The QuEChERS cleanup used 50 mg of C18 sorbent per one milliliter of extract to help remove coextracted fat compounds. Figure 5 shows that both the QuEChERS and dilution methods were less effective at minimizing matrix effects in avocado than they were in easier commodities like celery and kale. The QuEChERS method produced low matrix effects for 84% of analytes, which can still be considered tolerable performance. In contrast, the dilution method produced low matrix effects for just 64% of analytes, indicating that it was not able to mitigate matrix effects as well at the QuEChERS method for this matrix. This difference in performance is equivalent to about 20 analytes or one fifth of all target analytes. Figure 3 shows that the removal of matrix lipid material by dSPE cleanup improved matrix effects of analytes in the latter part of the analysis where coelution with lipid type compounds is expected.

The poor performance of both methods for lime is not surprising as citrus fruits are known to be difficult to analyze by LC-MS/MS methods [2,3,4,8]. Despite the challenges, pesticide residue testing for citrus commodities is still performed by LC-MS/MS so we included lime in this work. The QuEChERS method produced low matrix effects for only 22% of analytes while the dilution method did so for 30% of analytes, which is a difference of about eight compounds. It is thought that compounds specific to citrus fruit peel interfere with ionization [7,8].

Grains also present challenges for sample preparation because they are dry and contain high levels of coextracted material. For these reasons, a modified QuEChERS method was used as described earlier. The high amount of coextractives can intensify matrix effects, making LC-MS/MS pesticide residue analysis difficult. For brown rice flour, the performance of the methods is significantly different (Figure 5). The modified QuEChERS method shows low matrix effects for 98% of analytes, while the dilution method did so for only 42%. This equates to about 55 analytes for which the QuEChERS method produces acceptably low matrix effects, but that fall outside the range of the dilution method. This indicates that the dilution factor of 20 was not able to reduce the coextractives concentration to the degree needed to produce workable matrix effects. The QuEChERS cleanup step was able to remove carbohydrates and fatty acids that are commonly found in high levels in grains. This was accomplished by the use of PSA sorbent and makes a significant difference with respect to matrix effects.

Both QuEChERS and dilution methods performed well for high water commodities. With these types of samples, the dilution approach offers time savings in both sample processing and also in standard preparation because solvent standards can be used for calibration. As commodities become more challenging with higher concentrations of coextractives, especially fat and carbohydrates, QuEChERS shows better performance by removing more coextracted material compared to the dilution method used in this work. This is demonstrated by the significant differences observed for avocado and brown rice flour. To mitigate matrix effects, QuEChERS provides a good option for pesticide residue testing because it works well for many foods and pesticides and the time and cost expense is small compared to other sample cleanup techniques.

Sample Preparation/Calibration Method Combinations Evaluation

We evaluated the performance of the two sample processing strategies combined with two different calibration methods to determine the best combinations for different commodity types. We know from the discussion above that a dilution method can save time during sample processing. However, if a dilution method requires matrix-matched calibration, this adds significant time to the overall experiment. In some cases, it may be beneficial to process the samples with a more time consuming sample preparation method that would allow the use of solvent calibration. When feasible, analyzing dilution-only samples with solvent calibration is faster and less expensive; however, sometimes acceptable results can only be achieved by using sample cleanup and matrix-matched calibration, which requires significantly more resources. Our evaluation of sample preparations paired with different calibrations methods will help establish recommendations for choosing which strategies to apply.

Figure 7:   Percent recovery distribution comparing sample preparation and calibration strategy combinations for celery samples. (See Table VI for abbreviation key.)

Percent recovery distribution comparing sample preparation and calibration strategy combinations for celery samples.

Percent recovery values for all analytes, excluding incurred pesticides, were calculated for each commodity and sample preparation approach using both solvent and matrix-matched calibrations. This yields percent recovery values for each pesticide for the four sample preparation/calibration combinations. This was done at two fortification levels, 500 ppb and 10 ppb. The 500 ppb level was selected to begin with because we thought based on experience that all or most of the pesticides at this level could be quantified even after 10x and 20x dilutions. Fortified samples were also prepared at 10 ppb because this is the default maximum residue limit (MRL) for pesticides in foods if a specific value is not set.

We sorted pesticides into recovery value ranges and plotted these to produce the graphs in Figure 7. The plot shows the percentage of total compounds that fell within the recovery range labeled on the x-axis for celery. The 80-120% recovery range is considered satisfactory for quantitative work. These plots can be used to compare biasing of recovery values between sample preparation/calibration strategies. When these plots were compared for each commodity, generally we saw the same biasing trend towards either high or low recovery values for all four strategies. There were a couple of exceptions where biasing was removed because of the use of matrix-matched calibration, not because of different sample preparation (e.g., lime using QuEChERS method at 500 ppb and avocado using the dilution method at 10 ppb [data not shown]). Biasing was only removed by the use of matrix-matched calibration.

We calculated the percent of compounds that fell within the acceptable recovery range (80 to 120%) and used this to compare sample preparation/calibration method combinations. This is done for each commodity at both the 500 and 10 ppb fortification levels (Figures 8-12). Graphs are used for easy visual comparison and the percent values are listed inside the top of each bar. During analysis, the signal response for some analytes fell below the quantification level or was not detected. In this case, the number of compounds that were not able to be detected or quantified is given above the bar. This is an important parameter for evaluating different testing strategies. For example, in Figure 8, all analytes could be quantified at the 500 ppb level as anticipated. At the 10 ppb level, the QuEChERS method with either solvent or matrix-matched calibration allowed quantification of all analytes. However, for the dilution method, eight analytes could not be quantified by solvent calibration and nine compounds could not be quantified using matrix-matched standards.

Figure 8:   Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in celery. (See Table VI for abbreviation key.)

Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in celery.

Of the commodities tested, celery is the easiest to analyze because it is mainly water. While the extract contained some pigmentation, color intensity was reduced significantly by both the dilution and QuEChERS methods. The 500 ppb data indicate that both the QuEChERS and dilution techniques work well, but there is some advantage using a matrix-matched calibration with the dilution method. This equates to about 10 compounds.

At the 10 ppb level results for the four strategies show similar results. However, the dilution method was not able to detect all of the pesticides regardless of calibration strategy. The injection concentration was 0.5 ppb, which is close the detection limit for some of the 102 pesticides tested. Because there is no advantage with respect to recovery values using the dilution method, choosing the QuEChERS method or at least decreasing the dilution factor are the best options for detectability reasons.

Figure 9:   Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in kale. (See Table VI for abbreviation key.)

Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in kale.

Kale is considered slightly more difficult due to its higher pigment content, but it is still a relatively easy commodity because it has high water content. For the 500 ppb level shown in Figure 9, the performance is similar between the four sample preparation/calibration strategies. We see again a small increase for the dilution method when using a matrix-matched calibration curve. For the 10 ppb level, the methods performed similarly with the exception of the QuEChERS/matrix-matched calibration scheme. This is surprising as the trend is to see improvement with matrix-matched calibration. The dilution method performs as well as the QuEChERS method but the tradeoff at the lower concentration is failure to detect some pesticides.

Figure 10:   Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in avocado. (See Table VI for abbreviation key.)

Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in avocado.

Avocado is a high fat commodity with about 15% lipid content. It can be a difficult matrix to analyze because some lipids are coextracted in acetonitrile along with the pesticides. At the 500 ppb level, the four different strategies produced similar results, but improvement was seen when using matrix-matched calibration (Figure 10). For the lower fortification level, the benefit seen from using matrix-matched calibration is even stronger. When employing solvent calibration, the QuEChERS approach resulted in more compounds with acceptable recovery values than the dilution method, likely because the QuEChERS procedure used C18 sorbent to remove some of the coextracted lipid material. The dilution method was noticeably inferior, probably because dilution was not able to decrease ionization problems caused by coextracted lipids. This is supported by the matrix effects data showing that matrix effects were more pronounced at the end of the chromatographic analysis where lipids would be expected to elute (Figure 3).

Matrix effects are significant for the dilution/solvent calibration scheme, but using matrix-matched calibration compensated well and produced better recovery values. The QuEChERS/matrix-matched calibration data is almost identical to the dilution/matrix-matched calibration method, but with fewer compounds lost due to sensitivity at the 10 ppb level. In the cases of the compounds that are not detected, the three pesticides not detected using QuEChERS methods are the same and are included in the seven that were not detected for the dilution methods. This is common for undetected pesticides and indicates that the losses are due to sensitivity limitation and are not associated with loss due to QuEChERS sample cleanup. However, there are occasions when the commodity (rice) or the cleanup (GCB) causes low recovery and at 10 ppb these pesticides are difficult to detect.

Figure 11:   Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in lime. (See Table VI for abbreviation key.)

Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in lime.

It is well known that LC-MS based techniques struggle with citrus fruits but we still wanted to compare the sample preparation and calibration methods. At the 500 ppb level, recovery values are poor for all methods (Figure 11). There is a 20% increase, or about 20 compounds, for the QuEChERS method when matrix-matched calibration is used. This demonstrates the influence matrix-matched calibration can have on data quality. The dilution method shows similar results between solvent and matrix-matched calibration. At 10 ppb, it is apparent that this is a difficult matrix for trace analysis by the 21 and 39% values produced with solvent calibration. It is also apparent that the use of a matrix-matched curve can compensate for matrix effects for many pesticides. Using a matrix-matched curve for both the dilution and QuEChERS sample preparation methods significantly increases the number of pesticides that show good recovery, by about 20 and 40 compounds respectively. It is important to note that the dilution methods lost detectability for 8 compounds.

Figure 12:   Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in brown rice flour. (See Table VI for abbreviation key.)

Comparison of percent of pesticides with acceptable recoveries (80-120%) by sample preparation/calibration strategy at 500 and 10 ppb fortification levels in brown rice flour.

Brown rice flour has low water content and high carbohydrate composition. Dry commodities, like grains, present analytical challenges as they produce extracts with a high concentration of coextractives. The dilution/solvent calibration strategy suffers greatly and is not a viable method for this type of matrix (Figure 12). Matrix-matched calibration is extremely advantageous when used with the dilution method at both concentration levels. For the QuEChERS method, with both solvent and matrix-matched calibration, data show the benefit of removing some of the coextractives with dSPE cleanup. This cleanup step used here included PSA, which can remove fatty acids. This should be helpful for grains that are known to contain high amount of fatty acids in the extract. Because of the low values at the 10 ppb level for all four schemes, it is likely that some combination of rigorous cleanup, high dilution, and matrix-matched calibration will be needed to yield acceptable results.

Several ideas result from the evaluation of different sample preparation/calibration approaches. All strategies will struggle to produce good recovery values as commodity types become more difficult and are susceptible to stronger matrix effects. This might require adjustment to experimental design to achieve acceptable results. For all foods tested in this work, there is a tradeoff between spending time on sample cleanup and losing detectability of some analytes due to sensitivity limitations. This can be alleviated by higher dilution factors when instrumentation allows, but for some commodities actual removal of coextractives may be needed. Matrix-matched calibration is a powerful strategy to ensure data quality.

Conclusions

Matrix effects must be considered during method development of any pesticide residue method because of their drastic impact on data quality. Sample preparation strategies should be designed and tested to minimize matrix effects and ensure good data quality. Matrix effect studies can be useful for determining the regions of a chromatogram that are severely affected by matrix effects and, therefore, yield information about the nature of the interfering compounds. This information can steer changes to chromatographic conditions to minimize analytes eluting with interfering compounds or identify the best sample cleanup approach. In general, severe matrix effects require more sample preparation or higher dilution factors.

The choice of sample preparation and calibration methods is highly dependent on the commodity. Easy commodities with high water content are likely to be successful with either QuEChERS or dilution approaches, and the use of matrix-matched calibration may not be needed. Commodities that produce severe matrix effects, like grains, require some sample preparation or higher dilution factors, as well as matrix-matched calibration. Foods that have high fat content can be challenging and will require some sample cleanup, high dilutions and likely matrix-matched calibration. For the most difficult commodities, like dry grains, successful methods will likely involve substantial sample cleanup in combination with dilution and matrix-matched calibration. Matrix-matched calibration was the most effective way to improve results, regardless of sample preparation technique. Sample preparation is costly and time consuming and can sometimes result in the removal of analytes during processing, but it is sometimes needed for these types of commodities. Dilution methods do not require this time and financial investment during sample processing. However, high dilutions will be needed in many cases and this will cause some analytes to fall below limits of detection and may require the use of newer, more expensive instrumentation. These are some of the variables and tradeoffs that need to be considered when developing pesticide residue testing schemes.

References

[1] S. Kittlaus, J. Schimanke, G. Kempe, K. Speer, Assessment of sample cleanup and matrix effects in the pesticide residue analysis of foods using postcolumn infusion in liquid chromatography–tandem mass spectrometry, J. Chromatogr. A 1218 (2011) 8399.
[2] C. Ferrer, A. Lozano, A. Agüera, A.J. Girón, A.R. Fernández-Alba, Overcoming matrix effects using the dilution approach in multiresidue methods for fruits and vegetables, J. Chromatogr. A 1218 (2011) 7634.
[3] A. Kruve, A. Künnapas, K. Herodes, I. Leito, Matrix effects in pesticide multi-residue analysis by liquid chromatography–mass spectrometry, J. Chromatogr. A 1187 (2008) 58.
[4] H. Stahnke, S. Kittlaus, G. Kempe, L. Alder, Reduction of matrix effects in liquid chromatography−electrospray ionization−mass spectrometry by dilution of the sample extracts: how much dilution is needed? Anal. Chem. 84(3) (2012) 1474.
[5] AOAC Official Method 2007.01, Pesticide Residues in Foods by Acetonitrile Extraction and Partitioning with Magnesium Sulfate, 2007.
[6] EN 15662, Foods of Plant Origin—Determination of Pesticide Residues Using GC-MS and/or LC-MS/MS Following Acetonitrile Extraction/Partitioning and Clean-up by Dispersive SPE (QuEChERS-method), 2008.
[7] K. Mastovska, K.J. Dorweiler, S.J. Lehotay, J.S. Wegscheid, K.A. Szpylka, Pesticide multiresidue analysis in cereal grains using modified QuEChERS method combined with automated direct sample introduction GC-TOFMS and UPLC-MS/MS techniques, J. Agric. Food Chem. 58(10) (2010) 5959.
[8] J. Hajslová, J. Zrostlíková, Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices, J. Chromatogr. A 1000 (2003) 181.

Ricerche correlate

LC-MS/MS pesticide residue

,

QuEChERS method for pesticide

,

matrix effect pesticide residue