Cartucce

Products

Resprep CarboPrep Plus SPE Cartridges

  • Designed specifically for the cleanup of sample extracts for organochlorine pesticides analysis.
  • Excellent alternative to Florisil products, especially for the removal of nonvolatile matrix components that contaminate GC inlets and columns.
  • Proprietary treatment renders the carbon consistent and clean, ensuring the same selectivity tube to tube, and lot to lot with no interfering background.
  • Uses the same hardware, solvents, and solvent volumes as traditional Florisil cleanup, so switching is simple.

Visualizza le informazioni del prodotto

Cartucce SPE Resprep CarboPrep

  • Improved recovery of sulfonylurea herbicides, phenols, carbamates, and triazine herbicides, compared to C18 and C8 cartridges.
  • Wide range of selectivity for both analytes and their metabolites or degradation products.
  • Rapid sampling flow rates; uncompromised recoveries.
  • Maximum capacity for contaminant cleanup.
  • Controlled manufacturing improves cleanliness and ensures reproducible performance.
  • Excellent performance removing pigments from samples.

Visualizza le informazioni del prodotto

Cartucce SPE per cleanup di pestici residuali

  • Convenient, multiple adsorbent beds in a single cartridge.
  • For use in multiresidue pesticide analysis to remove matrix interferences.
  • Excellent for cleanup of dietary supplement extracts.

Visualizza le informazioni del prodotto

Cartucce SPE per metodo specifico

These cartridges have been specifically designed to provide consistent and reproducible results for the method or application stated.

Visualizza le informazioni del prodotto

Cartucce SPE Resprep (Fase Diretta)

Hydrophilic (polar) adsorbents used to extract hydrophilic analytes from nonpolar matrices, such as organic solvents (e.g., polar contaminants from sample extracts).

Visualizza le informazioni del prodotto

Cartucce SPE Resprep per Frazionamento EPH

  • Separazione completa di composti alifatici e aromatici in frazioni distinte.
  • Livello di background garantito sotto le soglie limite di segnalazione descritte nei metodi americani EPH Massachussets (MA) e New Jersey (NJ).
  • Livello superiore di riproducibilità tra lotto e lotto e stabilità durante lo stoccaggio assicurata da rigorosi test di Controllo Qualità e imballaggi resistenti all’umidità.
  • Scegli e cartucce da 5 g per una maggiore capacità di carico; usa le cartucce da 2 g per sistemi automatizzati, per risparmiare tempo e ridurre le quantità di solvente utilizzato.

Visualizza le informazioni del prodotto

Prodotti SPE Resprep PLR

  • Rimuove proteine e fosfolipidi da campioni biologici con un’unica, semplice ed efficiente procedura.
  • Evita la soppressione del segnale dovuta ai fosfolipidi rimuovendoli dalla matrice del campione.
  • Risparmia tempo— preparazione del campione semplice ed efficace per composti acidi, basici e neutri.
  • SPE Resprep PLR è offerto in formato piastra da 96 pozzetti per flussi di lavoro ad alta produttività (high-throughput) /automatizzati, e in formato cartuccia per applicazioni a ridotta produttività.
  • Compatibile con i dispositivi di filtrazione più comuni:
    • Collettori Sottovuoto
    • Collettori a Pressione Positiva
    • Centrifugazione

Visualizza le informazioni del prodotto

Resprep Polymeric SPE Cartridges and 96-Well Plates (Reversed Phase)

  • Silica-free, bonded polymeric material—no unwanted secondary silica interactions, even with basic compounds.
  • High surface area—higher loading capacity compared to silica-based sorbents.
  • Stable over a wide pH range (0–14)—won’t hydrolyze under extreme conditions.
  • Water-wettable—streamlined conditioning and equilibration steps drastically reduce solvent usage and sample prep time.
  • No flow-rate dependence—maintains retention and capacity after conditioning, even if dried out from vacuum or positive pressure flows.
  • Choose cartridges for high loading capacity; 96-well plates for high throughput and automation.

Visualizza le informazioni del prodotto

Cartucce SPE chiuse: Sodio solfato attivato

  • Sodio solfato anidro di alta qualità .
  • Cartucce SPE chiuse impaccate con 2g di sodio solfato anidro. Ingresso ed uscita luer femmina e maschio, compatibili con siringhe usa e getta e le più comuni strumentazioni.
  • L’adsorbente è completamente deattivato e pronto all’uso per la rimozione di acqua in eccesso dai solventi organici prima di varie analisi GC,HPLC, ecc.
  • Le cartucce chiuse mantengono il sorbente nelle condizioni ottimali garantendo ottime performance anche nel caso vengano conservate in laboratorio per molto tempo.

Visualizza le informazioni del prodotto

Cartucce SPE reversing CarboPrep

  • High adsorbent capacity (surface area ~200 m2/g) for large volume sampling.
  • Chromatographic grade graphitized carbon provides consistent and quantitative recoveries of a wide variety of semivolatiles, pesticides, and herbicides.
  • 500 mg bed weight.

Visualizza le informazioni del prodotto

Parti ed accessori per tubi SPE Resprep

Resprep tubes, frits, caps, and connectors for your method development needs.

Visualizza le informazioni del prodotto

Cartucce SPE Resprep (Fasi inverse legate)

Hydrophobic (nonpolar) silica-based adsorbents; used to extract hydrophobic analytes from polar matrices, such as water (e.g., pesticides from water).

C18 (high load, endcapped)


Visualizza le informazioni del prodotto