Accessori per la fase mobile

Accessori per la fase mobile

Products

Indicatore di scarico e sfioratore per sistemi LC

  • Avoid messy pooling around mobile phase waste containers.
  • Audible alarm instantly alerts user, preventing overflow.
  • Compact, battery-operated unit.
  • Available for 4-liter and GL-45 solvent bottles.

Visualizza le informazioni del prodotto

Kit filtro copribottiglia

Kit includes one each of: bottle adaptor; bottle adaptor nut; filter inlet cap; grid support; vacuum hose barb; tube compression fitting; 47 mm grid; 47 mm x 0.22 µm filter membrane; 47 mm x 0.45 µm filter membrane; 1/4" OD x 1/8" ID ultra-chemical resistant, FEP (fluorinated ethylene propylene)-lined Tygon tubing (3'); 6" x 6" box with shrink wrap insert.

Designed for 4 L bottles with GL-38 threads.

Visualizza le informazioni del prodotto

Adattatori copribottiglia

Allow the use of the Mobi-Cap Top with 4-liter solvent bottles.

Visualizza le informazioni del prodotto

Adattatori Mobi-Cap

Allow the use of the Hub-Cap Top with GL-45 solvent bottles.

Visualizza le informazioni del prodotto

Mobi-Cap per Bottiglie con tappo a vite GL-45, Kit

  • Kit convenienti per una facile gestione delle fasi mobili.
  • Proteggi la tua fase mobile dall'evaporazione e dalla contaminazione e dal diffondersi di vapori nocivi nel tuo laboratorio.
  • Include un tappo per bottiglia Mobi-Cap GL-45 a 3 porte (cat.# 27836).
  • Include tubo PTFE da 1/8" OD x 0,063 mm ID x 3 m (cat.# 27846).
  • Include due filtri sparger da 1/16": uno da 2 μm (cat.# 27827) e uno da 10 μm (cat.# 27828).
  • Disponibile con bottiglia/e GL-45 con o senza rivestimento di sicurezza.
  • Utilizzare una porta filettata 1/4-28 per il filtro di scarico o la valvola di ingresso dell'aria; altre porte possono essere utilizzate secondo necessità o chiuse con plug da 1/4-28 (venduto separatamente).

Visualizza le informazioni del prodotto

Mobi-Cap per Bottiglie con tappo a vite GL-45

  • Proteggi la tua fase mobile dall'evaporazione e dalla contaminazione e dal diffondersi di vapori nocivi nel tuo laboratorio.
  • Include dadi di connessione ai tubi con fascette colorate e ferrule.
  • Utilizzare una porta filettata 1/4-28 per il filtro di scarico o la valvola di ingresso dell'aria; altre porte possono essere utilizzate secondo necessità o chiuse con plug da 1/4-28 (venduto separatamente).

Visualizza le informazioni del prodotto

Eco-Cap per Bottiglie con tappo a vite GL-45

  • Proteggi economicamente la tua fase mobile dall'evaporazione e dalla contaminazione e e dal diffondersi di vapori nocivi nel tuo laboratorio.
  • Ordina l'adattatore Hub-Cap (cat.# 26538) per consentire l'uso di Eco-Cap su bottiglie da 4 litri.
  • Include tappo Luer maschio in polipropilene.
  • Nessuna filettatura per raccordi all'interno delle porte dei tubi; basta inserire il tubo.

Visualizza le informazioni del prodotto

Degasatore per fase mobile DEGASi

Efficienza di degasaggio ultra elevate in uno strumento piccolo e robusto.

  • Il sistema di controllo brevettato ZHCR (RPM variabile) mantiene il vuoto costante al fine di eliminare le fluttuazione della linea di base.
  • La membrane Systec AF è altamente permeabile ai gas, e caratterizzata da una camera con volume ridotto pari a 480 μL per un equilibrio rapido del sistema e utilizzo immediato.
  • Il percorso del flusso è biocompatibile e offer un’ampia compatibilità chimica.
  • Monitoraggio continuo del sistema di vuoto per garantire che le condizioni operative ottimali siano mantenute.
  • Funzioni di identificazioni di errore e perdite avanzate (vedere il manual di istruzioni).
  • Utilizzabile e compatibile con qualsiasi Sistema HPLC.
  • Conformità CE & RoHS.

Visualizza le informazioni del prodotto

Filtro per solvente in vetro Bluestem

  • Restek Bluestem glass solvent filter provides clean mobile phase to extend the life of columns and pump seals.
  • 15 µm borosilicate glass frit sits lower than conventional glass filters to draw more mobile phase from each bottle.
  • Blue filter stem allows instant visual confirmation of upright filter orientation.
  • Connects to standard 1/8" OD (3.2 mm) PTFE tubing using your existing frit adaptor (also sold separately as cat.# 26392).

Visualizza le informazioni del prodotto

Bottiglia da 4 litri con copribottiglia

Hub-Cap bottle tops are a great way to neatly keep your mobile phase lines where they belong. Use them instead of plastic paraffin film, aluminum foil, or tape on your mobile phase reservoirs.

Visualizza le informazioni del prodotto

Filtro di Sicurezza per Esausti con Indicatore

  • L'indicatore cambia da rosa chiaro a rosa scuro per notificare quando cambiare il filtro.
  • Il filtro di sicurezza protegge il tuo laboratorio dai composti volatili contenuti nelle bottiglie dei rifiuti.
  • Filettatura da 1/4-28 per l'uso sui tappi Mobi-Cap o Hub-Cap.
  • Sostituire il filtro ogni 3 mesi o quando l'indicatore cambia colore; sostituire più frequentemente in caso di uso massivo o in ambienti difficili.

Visualizza le informazioni del prodotto

Filri Sparger, Filtri Fase Mobile

  • Preparare e mantenere, senza grandi spese, fasi mobili prive di ossigeno, azoto e altri gas atmosferici disciolti.
  • Scegli un connettore senza flangia per tubi con OD da 1/16" o 1/8".
  • Elementi filtranti disponibili in acciaio inossidabile 316 o PE metal-free.
  • Connectore in PEEK, ferrula di connessione senza flangia in ETFE (non nel percorso di flusso).

Visualizza le informazioni del prodotto

Last Drop, Filtri Fase Mobile

  • Proteggi il tuo strumento e la colonna filtrando la tua fase mobile di contaminanti e particolati.
  • Scegli un connettore a gradini per tubi da ID 1.5/2.2/3.5 mm o connettore senza flangia per tubi con OD 1/8".
  • Elementi filtranti disponibili in acciaio inossidabile 316 o PTFE metal-free.
  • Custodia in PTFE, connettore in PEEK, ferrula di connessione senza flangia in ETFE non opzionale (non nel percorso di flusso).

Visualizza le informazioni del prodotto

Valvole e Filtri per Tappi di Bottiglie della Fase Mobile

  • Le valvole di ingresso proteggono il tuo laboratorio da composti volatili; utilizzare con un filtro per proteggere la fase mobile dalla contaminazione batterica.
  • La valvola di scarico regola la pressione durante lo sparging di elio.
  • Filettatura da 1/4-28 per l'uso sui tappi Mobi-Cap o Hub-Cap.
  • Sostituire le valvole ogni 6 mesi e filtri ogni 3 mesi; da sostituire più frequentemente in caso di uso massivo o in ambienti difficili.

Visualizza le informazioni del prodotto

Attenuatore d'impulsi UHP

The UHP pulse dampener provides minimal flow pulsation at system pressures up to 18,000 psi. Its low dead volume (220 µL at atmospheric pressure) reduces overall system volume for UHP applications. The UHP pulse dampener has a stainless steel fluid path.

Visualizza le informazioni del prodotto

Miscelatore raccordo a T ternario

  • Reduced baseline noise.
  • Increased sensitivity.
  • Improved gradient accuracy for more reproducible results.
  • Increased reaction efficiency in post-column derivatization.
  • Stainless steel.

Visualizza le informazioni del prodotto

Modulo controllo temperatura riscaldatore/refrigerante LC sidewinder e supporto colonna

  • Operation range: 555 °C, ±0.2 °C.
  • Ability to program multiple temperature points.
  • Accommodates columns up to 30 cm in length and 7.8 mm ID.
  • Compact design.

Visualizza le informazioni del prodotto

Fornetto Sidewinder per colonne LC

  • Semplice da usare
  • Range di operatività: 5 °C sopra temperature dell’ambiente fino a 85 °C, ±1 °C.
  • Design leggero e compatto si adatta a spazi ristretti.
  • L’holder della colonna può essere orientato in varie direzioni.

Visualizza le informazioni del prodotto

Attenuatore d'impulsi FlatLine

  • Rupture-proof, no diaphragmminimal risk of failure or leaks.
  • Clean flush-out designno sample carryover.
  • Low internal volumenegligible effect on analyte bandwidth.

Visualizza le informazioni del prodotto

Miscelatori in linea statici HyperShear

  • Reduced baseline noise.
  • Increased sensitivity.
  • Improved gradient accuracy for more reproducible results.
  • Increased reaction efficiency in post-column derivatization.
  • Stainless steel or PEEK.

Visualizza le informazioni del prodotto

QuickSplit Splitter di Flusso post-colonna

Sviluppato con tecnologia fluid resistor che elimina la necessità di intervenire sui tubi capillari. Disponibile ampia gamma di resistor intercambiabili.

Visualizza le informazioni del prodotto

Attenuatore di impulsi MiniPulse

  • Unità compatta (2.5” x 1.5”) posizionabile quasi ovunque.
  • Migliora la stabilità di base del sistema minimizzando il volume morto (solo 160 μL a pressione atmosferica).
  • Ideale per applicazioni in cui è necessario minimizzare il volume totale del sistema.

Visualizza le informazioni del prodotto

Apparecchio per eliminare bolle di solvente

Bubbles in an LC system can cause check valve malfunctions and pump cavitation, seriously affecting pump performance. The debubbler removes bubbles from the fluid stream before it enters the pump.

Special geometry at the base of the housing allows bubbles entrained in the inlet fluid stream to rise and be trapped in the reservoir. The gas/liquid interface is easily visible through the translucent wall of the device. Loosening the airtight cap releases the trapped gas. The debubbler features a polypropylene body and bracket; universal inlet and outlet connecting tips are made of 316 stainless steel and accept 0.063", 0.085", and 0.125" ID tubing.

Visualizza le informazioni del prodotto

Filtro in linea a tazza ad alta pressione

This high-pressure cup-type filter can be used in fluid streams operating to 15,000 psi (103,421 kPa). The cup-shaped filter elements have a large (2.5 cm2) surface area to give long operating lifetime. Mounted in screw-type adapters, they are easily removed for cleaning. Normally, backflushing and cleaning in an ultrasonic bath with an appropriate solvent will restore them. If they become permanently clogged, replacement elements are available.
Housings and all wetted parts are 316 stainless steel. Filters are packaged with gland nuts and ferrules. A bulkhead type fitting is available for thru-panel mounting. Tubing 1/16" OD; connectorsCPI.

Visualizza le informazioni del prodotto

Vetro a membrana microfiltrante

This 47 mm filtration apparatus with fritted glass support is recommended for routine filtration of corrosive liquids and removal of particles from LC solvents. The ground joint connection eliminates phthalate contamination that can occur when using silicone or neoprene stoppers. The support base has a coarse-porosity glass frit and an integral vacuum connection, located above the drip tip to prevent contamination of the vacuum line with filtrate droplets. Each apparatus includes a funnel, an anodized aluminum clamp, a 47 mm fritted glass support base, and a filtration flask.

Visualizza le informazioni del prodotto

Filtro di aspirazione CPI a bassa pressione per serbatoio fase mobile

A 316 stainless steel knurled cap and Tefzel CPI ferrule seal to 1/8" OD PTFE tubing when finger-tightened onto the precision-machined filter holder. The filter element is replaceable. Standard 10 µm porosity protects delicate pump components from particles but introduces very little pressure drop. 1/8" OD. May be used as a helium sparging diffuser.

Visualizza le informazioni del prodotto

Filtro di aspirazione slip-on a bassa pressione per serbatoio fase mobile

A 316 stainless steel tip with a Tefzel collar seals to a corrosion-resistant 316 stainless steel filter element. The slip-on filter easily attaches to the pump inlet line, without the use of wrenches. The universal 1/8" OD tip accommodates standard PTFE tubing inner diameters. The cylindrical filter is standard 10 µm porosity. Fits Altex, ISCO, LDC, Varian, Waters, PerkinElmer, and other pumps.

Visualizza le informazioni del prodotto

Attenuatore d'impulsi LO-Pulse

The LO-Pulse Pulse Damper is a patented, wide-dynamic-range 316 stainless steel device that smooths pulsations and maintains constant flow at system pressures from 500 to 6,000 psi (3,447 to 41,369 kPa). The flow path volume is only 0.9 mL and the path is efficiently swept, eliminating solvent memory effects when changing mobile phases. Flow rate range of 0.01 to 100 mL/min.

The LO-Pulse pulse damper also is available in a space-saving, economical kit that includes hardware for mounting the pulse damper on a bracket, or for installing feet on it for bench-top use. Shipped with PEEK plugs. Includes nuts and ferrules for use with 1/16" tubing in the 10-32 coned inlet and outlet ports.

Visualizza le informazioni del prodotto

Tubo in PTFE

  • Tubo chimicamente inerte disponibile in ID 0,094" e 0,063".
  • OD 1/8" in lunghezze da 3 e 10 metri.
  • Taglia facilmente la lunghezza di interesse con il Tagliatubi Clean-Cut (cat.# 25069).
  • Temperatura massima: 100 ° C.
  • Filettatura da 1/4-28 per l'uso sui tappi Mobi-Cap o Hub-Cap.

Visualizza le informazioni del prodotto

Raccordi e Ferrule per tubi da 1/8" & 1/16"

  • Ideale per chiudere e connettere in sicurezza tubi in PTFE ai tappi delle bottiglie Mobi-Cap.

Visualizza le informazioni del prodotto