delim
cis-Chlordane Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

cis-Chlordane

CAS # 5103-71-9


Masse molaire409.7786
FormuleC10H6Cl8
= Sources de données : ChemSpider

Synonymes

cis-Chlordane; α-Chlordan; α-Chlordane; cis-Chlordan; Chlordan, cis-; Chlordane cis; cis-Clordano; 4,7-Methano-1H-indene, 1,2,4,5,6,7,8,8-octachloro-2,3,3a,4,7,7a-hexahydro-, (1α,2α,3aα,4β,7β,7aα)-; 4,7-Methanoindan, 1α,2α,4β,5,6,7β,8,8-octachloro-3aα,4,7,7aα-tetrahydro-; 4,7-Methano-1H-indene, 1,2,4,5,6,7,8,8-octachloro-2,3,3a,4,7,7a-hexahydro-, (1R,2S,3aS,4S,7R,7aS)-rel-; (1α,2α,3aα,4β,7β,7aα)-1,2,4,5,6,7,8,8-octachloro-2,3,3a,4,7,7a-hexahydro-4,7-methano-1H-indene


Cromatogrammi applicativi

EPA Method 525.3 OCP Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi®-5Sil MS
GC Multiresidue Pesticide Standard #2-OCP on Rxi®-5ms by GC-MS
GCxGC-TOFMS Contour Plot of Unfortified Detoxification Tea
GCxGC-TOFMS Contour Plot Showing Potential Isobaric Interference with Acephate (m/z 136) in 1D Analysis
GCxGC-TOFMS Contour Plot of Unfortified Berry Tea
7-Minute Analysis of Organochlorine Pesticides (EPA Method 8081) on Rtx®-CLPesticides and Rtx®-CLPesticides2 Using Hydrogen
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides
Organochlorine Pesticides US EPA Method 8081 on Rtx®-1701
Organochlorine Pesticides US EPA Method 8081 on Rtx®-440
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides2 (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides (0.32mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides2 (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides (0.53mm ID)
Organochlorine Pesticides US EPA Method 8081 on Rtx®-35
Organochlorine Pesticides US EPA Method 8081 on Rtx®-440
Organochlorine Pesticides US EPA Method 8081 on Rtx®-440
Organochlorine Pesticides US EPA Method 8081 on Rtx®-CLPesticides2
Organochlorine Pesticides Fast Analysis Conditions on Rtx®-CLPesticides & Rtx®-CLPesticides2 (dual column analysis)
Recovery of Chlorinated Pesticides from Solvent Extracts Using CarboPrep™ 90
Organochlorine Pesticides US EPA Method 8081 on Rtx®-XLB
Comparison: Florisil® SPE Cleanup of Blank Extract and EPA 8081 Pesticides Extract on Rtx®-CLPesticides2
Florisil® SPE Cleanup of EPA 8081 Pesticides on Rtx®-CLPesticides2
Organochlorine Pesticides, PCBs, and BFRs on Rxi®-XLB and Rxi®-17Sil MS (GCxGC-ECD)
Organochlorine Pesticides by U.S. EPA Method 8081A on Rtx®-CLPesticides2 (dual column w/ Rtx®-440)
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx®-50
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx®-5
Organochlorine Pesticides by U.S. EPA Method 8081 on Rtx®-CLPesticides2
Organochlorine Pesticides by EPA Method 508 on Rtx®-5
Semivolatile Organics by EPA Method 525 on Rtx®-XLB
Organochlorine Pesticide Mix AB #2 on Rtx®-CLPesticides2 and Rtx®-CLPesticides (0.53 mm ID column set)
Method 8081B Chlorinated Pesticides on Rtx®-CLPesticides2
Organochlorine Pesticides by EPA Method 8081A on Rtx®-440 (dual column w/ Rtx®-CLPesticides2)
Organochlorine Pesticides by EPA Method 8081B on Rtx®-CLPesticides/Rtx®-CLPesticides2 (extended list)
Organochlorine Pesticides by EPA 8081A on Rtx®-CLPesticides & Rtx®-CLPesticides2
Organochlorine Pesticides U.S. EPA Method 8081A Rtx®-XLB
Organochlorine Pesticides on Rtx®-CLPesticides Columns (0.18 mm ID column set)
Pesticides of U.S. EPA Method 505 on Rtx®-CLPesticides and Rtx®-CLPesticides2
Organochlorine Pesticide Mix AB #2 on Rtx®-CLPesticides2 and Rtx®-CLPesticides (0.32 mm ID column set)
Pesticides & Herbicides U.S. EPA Method 508.1 Rtx-CLPesticides & Rtx-CLPesticides2
Chlorinated Pesticide Residues in Olive Oil Rtx-CLPesticides2
Organochlorine Pesticides on Rtx®-CLPesticides2
Organochlorine Pesticides on Rtx®-CLPesticides
Organochlorine Pesticide Mix AB #2 Rtx®-CLPesticides and Rtx®-CLPesticides2 (0.25mm ID column set)