delim
Benzo[a]pyrene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Benzo(a)pyrene

CAS # 50-32-8


Masse molaire252.3093
FormuleC20H12
Point de fusion179 °C
Point d’ébullition495 °C
Densité1.24 g/cm³ (25 °C)
Solubilité dans l’eau0.11 mg/L (25 °C)
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Benzo[a]pyrene; Benz[a]pyrene; 1,2-Benzpyrene; 3,4-Benzopyrene; 3,4-Benzpyrene; 3,4-Benz[a]pyrene; 6,7-Benzopyrene; Benzo[α]pyrene; Benzo[d,e,f]chrysene; B(a)P; BP; 3,4-Benzopirene; 3,4-Benzpyren; 3,4-BP; Rcra waste number U022; Benzopyrene; Benzo[a]pireno; Benzo(a)pyrène; Benzo(a)pirene; NSC 21914


Cromatogrammi applicativi

MA DEP EPH Aromatics on Rxi-5Sil MS
NJ DEP EPH Aromatics on Rxi-5Sil MS
MA DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
NJ DEP EPH Aromatics on Rxi-5Sil MS by Split Injection
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 208 V GC Oven
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 Using the GC Accelerator Kit and Split Injection with a 120 V GC Oven
16 Priority PAHs and Methylnaphthalenes on Rxi- 5Sil MS using the GC Accelerator Kit in a 208 V Oven
16 Priority PAHs and Methylnaphthalenes on Rxi-5Sil MS using the GC Accelerator Kit in a 120 V Oven
EPA Method 525.3 PAH Calibration Standard (with 525.3 Internal and Surrogate Standards) on Rxi®-5Sil MS
EPA Method 525.3 Full Analyte List on Rxi®-5Sil MS
Resolution of Benzo Fluoranthene and Benzo Pyrene Isomers on Rxi®-PAH (60 m x 0.25 mm x 0.10 µm)
Select PAHs on Rxi®-PAH (60 m x 0.25 mm x 0.10 µm)
Semivolatiles on Rxi®-5ms (Split Injection)
EPA 8310 PAHs on Pinnacle II PAH by LC-UV
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi®-PAH (30 m x 0.25 mm ID x 0.10 µm df )
NIST SRM 1975, Diesel Particulate Extract, on Rxi®-PAH
Automated Solvent Extraction of NIST SRM 1941b, Organics in Marine Sediment, on Rxi®-PAH
Select Polycyclic Aromatic Hydrocarbons (PAHs) on Rxi®-PAH
Detailed Analysis of Polycyclic Aromatic Hydrocarbons (PAHs) in Creosote Oil on Rxi®-PAH
Semivolatiles on Rtx®-5 with 5 m Integra-Guard® by EPA Method 8270
9-Minute Semivolatiles Analysis with Appendix IX on Rxi®-5ms by U.S. EPA Method 8270D
PAHs in Sediment Extract on Rxi®-PAH (Sampled From Spring Creek, PA)
PAHs in Sediment Extract on Rxi®-PAH (Sampled From Spring Creek, PA)
Benzo[b]fluoranthene and Benzo[a]pyrene in a QuEChERS Extract of Mate Tea Separated from Potential Interfering PAHs on Rxi®-PAH
Semivolatile Organics in Drinking Water on Rxi®-5Sil MS by EPA Method 525.2
Semivolatiles With Appendix IX on Rxi®-5ms by 8270D
Semivolatiles on Rxi-5Sil MS by U.S. EPA Method 8270 (Split Injection)
Semivolatile Organics on Rxi®-5Sil MS by U.S. EPA Method 8270
NIST SRM 2260a PAH Mix on Rxi®-PAH
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx®-CLPesticides2
Polynuclear Aromatic Hydrocarbons US EPA Method 8100 on MXT®-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx®-5
Polynuclear Aromatic Hydrocarbons US EPA Method 610 on Rtx®-440
Semivolatiles US EPA Method 8270 on Rtx®-5Sil MS
Semivolatile Organics US EPA Method 8270 on Rtx®-5Sil MS
0.5 ng Semivolatile Organics with Appendix IX on Rxi®-5Sil MS by U.S. EPA Method 8270
Semivolatile Organics w/Appendix IX on Rxi®-5Sil MS by U.S. EPA Method 8270
PAHs and PCB Congeners on Rxi®-XLB
EU 15+1 PAH Mix on Pinnacle® DB PAH
EU 15+1 PAHs on Pinnacle II PAH (UV/Vis)
EPA 8310 PAH Mix on Pinnacle® II PAH (FLD)
EPA 8310 PAH Mix on Pinnacle® DB PAH
EU 15+1 PAHs on Pinnacle® II PAH (FLD)
Semivolatile Organics by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Single Taper Liner packed with Semivolatiles Wool
Semivolatile Organics by EPA Method 525 on Rtx®-XLB
Polycyclic Aromatic Hydrocarbons on Rtx®-50
Polycyclic Aromatic Hydrocarbons on Rxi®-17Sil MS
Polycyclic Aromatic Hydrocarbons on Rxi®-17
Polycyclic Aromatic Hydrocarbons on Rxi®-17 column
US EPA Method 8270D by GC/MS Rtx®-XLB
Polycyclic Aromatic Hydrocarbons on Rxi®-17 (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons on Rxi®-17Sil MS (15m x 0.25mm x 0.25µm)
Polycyclic Aromatic Hydrocarbons by EPA Method 610 on Rxi®-5ms
Semivolatiles on Rxi®-5ms by EPA Method 525.2
EPA Method 610 Polycyclic Aromatic Hydrocarbons on Pinnacle® DB PAH
QuEChERS Extract of NIST SRM 2974a Freeze-Dried Mussel Tissue (GCxGC contour plot)
Polycyclic Aromatic Hydrocarbons Infant Formula with and without QuEChERS dSPE Clean-up on Rxi®-5Sil MS
NJDEP EPH Aromatics on Rtx®-5
Polycyclic Aromatic Hydrocarbons by EPA 610 on Rxi®-5ms
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.25 µm) w/Drilled Uniliner
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (30m, 0.25mm ID, 0.50µm)
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (20m, 0.18mm ID, 0.18µm)
Semivolatiles by EPA Method 8270 on Rxi®-5Sil MS (20m, 0.18mm ID, 0.36µm)
Semivolatiles CLP Method on Rtx®-5MS
Polycyclic Aromatic Hydrocarbons Rxi®-5Sil MS