delim
C20 Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Icosane

CAS # 112-95-8


Masse molaire282.5475
FormuleC20H42
Point de fusion36-38 °C, 309-311 °K, 97-100 °F
Point d’ébullition343 °C, 616.2 °K, 649 °F
log P10.897
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Eicosane; n-Eicosane; Icosane; n-Icosane; C20


Cromatogrammi applicativi

Simulated Distillation on Rtx-1 SimDist 2887 DiatoSorb-WHP by ASTM D2887
Arabian Medium Crude Oil on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Mineral Oil Standard on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
South Louisiana Crude Oil on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 11 on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 1 on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 5 on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Diesel #2/Mineral Oil Standard on Rxi®-5HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 5 on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Florida Beach Tarball 1 on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Arabian Medium Crude Oil on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Iraqi Basrah Light Crude Oil on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard on Rxi®-1HT (15 m x 0.25 mm x 0.10 µm)
Florida TRPH Standard Mix on Rxi®-1HT
Petroleum Wax on MXT®-1
Solvent Mixture #1 on Rtx®-1
Solvent Mixture #1 on Rtx®-200
Solvent Mixture #1 on Stabilwax®
Solvent Mixture #2 on Rtx®-1
Solvent Mixture #2 on Rtx®-200
Solvent Mixture #2 on Stabilwax®
Solvent Mixture #3 on Rtx®-1
Solvent Mixture #3 on Rtx®-200
Crude Oil, Arabian Light on Rtx®-1
Crude Oil, Prudhoe Bay on Rtx®-1
Solvent Mixture #3 on Stabilwax®
C5-C72 Hydrocarbons on MXT®-1HT SimDist by ASTM D7213-05 (D2887 Extended))
C8-C100 Hydrocarbons on MXT®-1HT SimDist by ASTM D6352
C10-C40 Alkanes on Rxi®-5HT
Low Bleed, High Efficiency MXT®-1HT SimDist Columns Outperform Competitors for Simulated Distillation (ASTM D6352)
Hydrocarbons (C5-C106) on MXT®-1HT SimDist at 450 °C
Hydrocarbons (C5-C106) on MXT®-1HT SimDist at 430 °C
n-Alkanes on Rtx®-Mineral Oil
Petroleum Hydrocarbons (TPH) on Rxi®-1ms
Hydrocarbons (C7-C42) on Rtx®-1
Simulated Distillation (Standard Calibration) on MXT®-1 SimDist
n-alkanes (C10-C40) on Rtx®-Mineral Oil
Simulated Distillation by ASTM D2887 on Rtx®-1 SimDist 2887
C5 to C44 calibration on Rtx®-1 SimDist 2887
DRO Mix on Rtx®-5
Hydrocarbons (C10-C44) on MXT®-1HT SimDist
Simulated Distillation (C5-C44) on Rtx®-2887
NJDEP EPH Aliphatic Fraction on Rtx®-5