delim
1,3,5-Trimethylbenzene Compound Information and Applications for GC (Gas Chromatography) and LC (Liquid Chromatography) Analysis

Mesitylene

CAS # 108-67-8


Masse molaire120.1916
FormuleC9H12
Point de fusion-44.8 °C
Point d’ébullition164.7 °C
Densité0.8637 g/cm³ at 20 °C
= Sources de données : ChemSpider et Wikipedia

Spectre de masse (GC)

m/z
Sélectionnez et cliquez sur une zone pour zoomer, double-cliquez pour dézoomer.
Survolez les pics pour connaître les valeurs.

Synonymes

Benzene, 1,3,5-trimethyl-; Mesitylene; s-Trimethylbenzene; 1,3,5-Trimethylbenzene; sym-Trimethylbenzene; Fleet-X; Trimethylbenzol; TMB; 2,4,6-Trimethylbenzene; 3,5-Dimethyltoluene; NSC 9273; 1,3,5-trimethylbenzene (mesitylene); 1,3,5-Triméthylbenzène; 1,3,5-Trimetilbenzene


Cromatogrammi applicativi

PiONA Calibration Standard on Rtx-DHA-100 by ASTM D6729-14
Aromatics on Rtx-DHA-100 (ASTM D6729-14)
NJ Low Level TO-15 75 Component Mix on Rtx-VMS (30 m, 2.0 mL/min)
PAMS 57 Component Mix on Rtx®-1 (105 m)
25 µg/L 8260 MegaMix® Revised on Rtx®-VMS
40 ppb Volatiles in Drinking Water on Rtx®-VMS by EPA Method 524.4
TO-15 65 Component Mix on Rxi®-1ms (60 m)
TO-15 65 Component Mix on Rxi®-5Sil MS (30 m)
TO-15 65 Component Mix on Rtx®-VMS (30 m, 1.2 mL/min)
TO-15 65 Component Mix on Rtx®-VMS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rtx®-VMS (30 m)
Volatile Organics TO-15 Volatiles on Rtx®-1
TO-15 65 Component Mix on Rxi®-5Sil MS (30 m, 1.5 mL/min)
Alcohols and Acetates on Stabilwax®-MS
Volatile Organics US EPA Method 8260B on Rtx®-VMS
Reformate on Rtx®-1
Alaska Method AK101AA on Rtx®-5Sil MS (PID)
Alaska Method AK101AA on Rtx®-5Sil MS (FID)
Gasoline Aromatics on Rtx®-1
Gasoline Aromatics on Rtx®-1
EPA Method 524.2, Revision 4 Rtx®-VMS
Aromatics Stabilwax®
Aromatics Rtx®-502.2
TO-15 65 Component Mix on Rxi®-5Sil MS (30 m, 2.0 mL/min)
TO-15 65 Component Mix on Rxi®-5ms (30 m)
5 ppb Volatiles in Drinking Water on Rtx®-VMS by EPA Method 524.3
TO-15 65 Component Mix on Rxi®-624Sil MS (30 m)
TO-15 65 Component Mix on Rxi®-1ms (30 m)
EPA Method 524.2 on Rtx®-502.2
Volatile Organics by EPA Method 8021A/502.2 on Rtx®-502.2
Volatile Organics by EPA Method 502.2 on Rtx®-502.2
Volatile Organics Confirmational Analysis by EPA Method 502.2 on Rtx®-1
Volatile Organics by EPA 8260B & Oxygenates on Rtx®-VMS
Volatiles by EPA Method 8260 on Rxi®-624Sil MS (30m, 0.25mm ID, 1.40µm)
Aromatics on Rt®-TCEP
Mass APH on Rxi®-1ms
Volatile Organics by EPA 8260B on Rtx®-VMS
Volatile Organics by EPA 8260B on Rtx®-VMS
Volatile Organics by EPA 8021 on Rtx®-VRX
Ozone Precursors on Rtx®-1
Volatile Organics by EPA Method 8260 (80ppb Standard) on Rtx®-VMS
Volatile Organics by U.S. EPA Method 524.2 Revision IV on Rtx®-VMS