Flavor Compounds in Malt Whiskey on Stabilwax-DA

Peaks
1.Nonanoic acid
2.Diethyl 2-hydroxyglutarate
3.Unknown
4.Tetradecanol
5.4-Vinylguaiacol
6.Diethyl nonanedioate
7.Methyl hexadecanoate
8.Ethyl γ-lactone 2-hydroxyglutarate
9.Ethyl hexadecanoate
10.Decanoic acid
11.Ethyl 9-hexadecanoate
12.Triacosan
13.Unknown
14.Phthalide
15.Diethylphthalate
16.Hexadecanol
17.4-Hydroxycinnamic acid (decomp.)
18.Methyl stearate
19.Benzoic acid
Peaks
20.Methyl 8-octadecenoate
21.Ethyl stearate
22.Dodecanoic acid
23.Hydroxymethylfurfuraldehyde
24.Ethyl linoleate
25.4-Allyl-2,6-dimethoxyphenol
26.Diisobutyl phthalate
27.Vanillin
28.Sinapic acid (decomp.)
29.2-phenylethyl decanoate + 2 unknowns
30.4-(2-Propenyl)-2,6-dimethoxyphenol
31.Ethyl vanillate
32.Acetovanillone
33.Vanillin methyl ketone
34.Tetradecanoic acid
35.Ethyl homovanillate
36.Propiovanillone
37.fatty acid ester
38.(similar to 4-allyl-2,6-dimethoxyphenol)
39.unknown
image
GC_FF00557
ColumnStabilwax®-DA, 30 m, 0.18 mm ID, 0.18 µm (cat.# 550752)
Injection
Inj. Vol.:10 µL splitless
Oven
Oven Temp.:60 °C (hold 2 min) to 100 °C at 20 °C/min to 240 °C at 5 °C/min (hold 10 min)
Carrier GasHe, constant flow
Linear Velocity:45 cm/sec
DetectorMS
Mode:Scan
Transfer Line Temp.:240 °C
Source Temp.:230 °C
Quad Temp.:150 °C
Electron Energy:70 eV
Ionization Mode:EI
Scan Range:30-400 amu
NotesInj: 10µL/min
Std. conc.: neat
Gerstel CIS Injector: 35°C (hold 2 min.), to 300°C @ 10°C/sec. (hold 5 min.)
Helium vent flow: 600mL/min with 1.8 min. vent end time
AcknowledgementChromatogram courtesy of Kevin MacNamara, Ph.D., Irish Distilleries, Ltd.
Download PDF

Consigli per la stampa! Per stampare cromatogrammi su tutta la pagina, cambiare le impostazioni di stampa nella finestra di stampa del vostro software PDF reader: 1)"adatta" o "adatta alla pagina", 2)"panorama" per cromatogrammi grandi o "ritratto" per cromatogrammi alti.