Semivolatile Organics by EPA Method 525 on Rtx-XLB

Peaks
1.Isophorone
2.2-Nitro-m-xylene
3.Dichlorvos
4.Hexachlorocyclopentadiene
5.EPTC
6.Butylate
7.Mevinphos
8.Vernolate
9.Pebulate
10.Etridiazole
11.Dimethyl phthalate
12.Acenaphthene
13.2,6-Dinitrotoluene
14.Acenaphthene-d10
15.2-Chlorobiphenyl (BZ#1)
16.Chloroneb
17.Tebuthiuron
18.Molinate
19.Diethyl phthalate
20.2,4-Dinitrotoluene
21.Propachlor
22.Fluorene
23.Ethoprop
24.Cycloate
25.Trifluralin
26.Chlorpropham
27.2,3-Dichlorobiphenyl (BZ#5)
28.Atraton
29.Prometon
30.α-BHC
31.Hexachlorobenzene
32.Propazine
33.Simazine
34.Atrazine
35.Metribuzin
36.Diazinon
37.Terbufos
38.Propyzamide
39.Pentachlorophenol
40.γ-BHC (lindane)
41.Disulfoton
42.Terbacil
43.Phenanthrene-d10
44.Methyl parathion OA
45.Phenanthrene
46.Anthracene
47.β-BHC
48.2,4,5-Trichlorobiphenyl (BZ#29)
49.Alachlor
50.Prometryne
51.Ametryn
52.Simetryn
53.δ-BHC
54.Heptachlor
55.Chlorothalonil
56.Dibutyl phthalate
57.Terbutryn
58.Bromacil
59.Chlorpyrifos
Peaks
60.Metolachlor
61.DCPA methyl ester (Chlorthal-dimethyl)
62.2,2',4,4'-Tetrachlorobiphenyl (BZ#47)
63.Aldrin
64.Triadimefon
65.Cyanazine (Bladex)
66.MGK 264
67.Diphenamid
68.Merphos
69.2,2',3',4,6-pentachlorobiphenyl (BZ#98)
70.Heptachlor epoxide (isomer B)
71.Heptachlor epoxide (isomer A)
72.Butachlor
73.Stirofos (tetrachlorvinphos)
74.Fenamiphos
75.cis-Chlordane*
76.Napropamide
77.trans-Chlordane*
78.Endosulfan I
79.trans-Nonachlor
80.Pyrene-d10
81.Pyrene
82.4,4'-DDE
83.2,2',4,4',5,6'-Hexachlorobiphenyl (BZ#154)
84.p-Terphenyl-d14
85.Dieldrin
86.Carboxin
87.Chlorbenzilate
88.Tricyclazole
89.Endrin
90.4,4'-DDD
91.Bis(2-ethylhexyl) adipate
92.Butyl benzyl phthalate
93.Endosulfan II
94.Endrin aldehyde
95.Norflurazon
96.4,4'-DDT
97.Triphenylphosphate
98.Hexazinone
99.Endosulfan sulfate
100.Bis(2-ethylhexyl)phthalate
101.Methoxychlor
102.2,2',3,3',4,5',6,6'-Octachlorobiphenyl (BZ#207)
103.2,2',3,3',4,4',6-Heptachlorobiphenyl (BZ#171)
104.Endrin ketone
105.Benz[a]anthracene
106.Chrysene-d12
107.Chrysene
108.Fenarimol
109.cis-Permethrin
110.trans-Permethrin
111.Benzo[b]fluoranthene
112.Benzo[k]fluoranthene
113.Fluridone (Sonar®)
114.Benzo[a]pyrene
115.Perylene-d12
116.Dibenz[a,h]anthracene
117.Indeno[1,2,3-cd]pyrene
118.Benzo[ghi]perylene
* For information regarding the nomenclature used for cis-chlordane and trans-chlordane, visit www.restek.com/chlordane-notice
image
ColumnRtx-XLB, 30 m, 0.25 mm ID, 0.25 µm (cat.# 12823)
SampleMethod 525.2 Semivolatile Mix (cat.# 31824)
Method 525.2 PCB Congener Mix (cat.# 32420)
Method 525.2 Nitrogen/Phosphorus Pesticide Mix #2 (cat.# 32423)
Method 525.2 Internal Standard Mix (cat.# 31825)
Method 525.2 Surrogate Standard Mix (cat.# 31826)
p-terphenyl-d14 (cat.# 31828)
Organochlorine Pesticide Mix AB #1 (cat.# 32291)
Organochlorine Pesticide Mix AB # 3 (cat.# 32415)
metribuzin (cat.# 32436)
Conc.:5 ng per analyte
Injection
Inj. Vol.:1 µL pulsed splitless (hold 0.4 min)
Liner:Drilled Uniliner (hole near top) (cat.# 21055)
Inj. Temp.:300 °C
Pulse Pressure:30 psi (206.8kPa)
Pulse Time:0.4 min
Oven
Oven Temp.:35 °C (hold 2 min) to 260 °C at 20 °C/min to 330 °C at 6 °C/min (hold 5 min)
Carrier GasHe, constant flow
Flow Rate:1.0 mL/min
DetectorMS
Mode:Scan
Transfer Line Temp.:280 °C
Solvent Delay Time:4.7 min
Tune Type:DFTPP
Scan Range:45-550 amu
InstrumentHP6890 GC & 5973 MSD