Composti e classi

Cerchi un composto specifico?

Scrivi il nome di un composto, un sinonimo, o CAS number.

Products

Kit pesticidi multiresidui GC

  • Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.
  • Comprehensive 203-compound kit covers food safety lists by the FDA, USDA, and other global governmental agencies; individual ampuls also sold separately.

Visualizza le informazioni del prodotto

Kit pesticidi multiresidui LC

  • Accurately detect and quantify pesticides of global food safety concern in a wide range of fruits, vegetables, and other commodities by LC-MS/MS.
  • Full kit contains 204 compounds of interest, covering many LC-determined pesticides listed by government agencies; individual ampuls also sold separately.

Visualizza le informazioni del prodotto

EPA Method 525.3 Surrogate Standard (3 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 PCP IS

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 PAH IS Mix (3 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 PCB Cal Standard (14 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 PAH Cal Standard (20 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 ONP Cal Standard (44 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 OPP Cal Standard (16 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

EPA Method 525.3 OCP Cal Standard (29 components)

  • Developed specifically for EPA Method 525.3.
  • Formulated to provide maximum stability in concentrations convenient for dilution.
  • Simplifies and speeds up standard preparation.
  • Quantitatively tested to confirm composition; detailed support documentation provided.

Visualizza le informazioni del prodotto

Miscela di calibrazione MegaMix, rivista 8260 (75 componenti)

  • Contains 75 compounds in one convenient ampul for the analysis of VOCs in solid waste.
  • Quantitatively analyzed to confirm concentration and identity of each compound.
  • Excludes pentachloroethane for labs experiencing elevated tetrachloroethene response caused by pentachloroethane breakdown.

Visualizza le informazioni del prodotto

Standard di riferimento EPA 524.3 (5 miscele separate, compreso uno standard MegaMix)

  • Full 82-component EPA 524.3 list using as few as three ampulsreduce prep time and chances for error or contamination.
  • EPA 524.3 VOA MegaMix ampul includes oxygenates groupno need to order separately.
  • Volatile gases prepared separatelyreplace shorter-life components without wasting money on full list.
  • Two options for internal and surrogate standardsseparate or combined mix.
  • Also ideal for surface water and groundwater testing.

Visualizza le informazioni del prodotto

Kit MegaMix B/N CLP 04.1

Contains 1 mL each of these mixtures.
31903: CLP 04.1 B/N MegaMix Standard, Revision 2
31902: CLP/SVOA Additions Mix

Visualizza le informazioni del prodotto

Kit MegaMix SVOA SOM01.1

Contains 1 mL each of these mixtures.
31900: SOM01.1 SVOA MegaMix Standard, Revised
31902: CLP/SVOA Additions Mix

Visualizza le informazioni del prodotto

Kit VOA CAL2000 MegaMix CLP

Contains 1 mL each of these mixtures.
30632: CLP VOA CAL2000 MegaMix Standard
30216: vinyl acetate

Visualizza le informazioni del prodotto

Kit miscela di calibrazione MegaMix 8260

Contains 1 mL each of these mixtures.
30633: 8260 MegaMix Calibration Mix
30265: 2-chlorethyl vinyl ether

Visualizza le informazioni del prodotto

Standard MegaMix 8270 (76 componenti)

  • Fewest mixtures needed for calibration and matrix spikes.
  • Mixtures formulated for maximum stability.
  • Contains most routinely analyzed compounds.

Visualizza le informazioni del prodotto

Miscela di calibrazione MegaMix 8260 (76 componenti)

  • Contains 76 compounds in one convenient ampul for the analysis of VOCs in solid waste.
  • Quantitatively analyzed to confirm concentration and identity of each compound.

Visualizza le informazioni del prodotto

Standard MegaMix composti semivolatili, metodo EPA 625 (54 componenti)

  • MegaMix mixture includes all target compounds not in our current products.
  • Incorporates all phenols, for fast preparation and calibration.
  • Incorporates “additional” extractable Method 625 compounds.

Visualizza le informazioni del prodotto

Standard MegaMix 502.2 (54 componenti)

Includes all target analytes except the six gases, which are available separately as 502.2 Calibration Mix #1.

Visualizza le informazioni del prodotto

Standard qualitativo di Indice del Tempo di Ritenzione (27 composti)

  • Indicato per un' ampio range di sistemi di indice di ritenzione.
  • Materiale di riferimento certificato (CRM)stabile ed accurato.
  • Analizzato qualitativamente per confermarne la composizione; certificato disponibile per ogni lotto di CRM.

Visualizza le informazioni del prodotto

Standard UE 15+1 per gli idrocarburi policiclici aromatici (PAH) (16 componenti)

  • Formulated to contain the 16 major European Food Safety Authority (EFSA) PAH compounds.
  • High concentration (100 μg/mL) solution provides value and flexibility. Dilute as needed for fortification and calibration mixes.
  • Low-volatility toluene solvent provides longer shelf life, which helps ensure more accurate results.
  • Broad solvent miscibility—compatible with acetonitrile, the QuEChERS solvent.

Visualizza le informazioni del prodotto

Standard PAH4 EFSA (4 componenti)

  • European Food Safety Authority (EFSA) PAH4 compounds prepared in toluene solvent.
  • High 1,000 µg/mL concentrationdilute as needed to economically prepare custom mixes.
  • Low volatilitylonger shelf life and more accurate results.
  • High miscibilitycompatible with QuEChERS solvents.

Visualizza le informazioni del prodotto

Standard di calibrazione metodo 539 UCMR3 (7 componenti)

  • Contains the seven hormones listed in EPA Method 539 at concentrations suited for Unregulated Contaminant Monitoring Rule 3 (UCMR3) screening.
  • Ideal for the analysis of finished drinking water as outlined in UCMR3, which requires monitoring of all public drinking water systems with 10,000 or more customers.

Visualizza le informazioni del prodotto

Standard endrin aldeide

NOTE: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Standard endosulfan II

NOTE: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Standard endosulfan I

NOTE: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Standard endrin chetone

NOTE: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Standard endrina

NOTE: Cat. #s 32463–32468 are dissolved in acetone and replace cat. #s 32219–32224, which were dissolved in methanol.

Visualizza le informazioni del prodotto

Miscela N. 1, Appendice IX rivista (17 componenti)

Please note: Methapyrilene is not included in this revised standard.

Visualizza le informazioni del prodotto

Standard madre di calibrazione EPA 539 (7 componenti)

  • Contains the seven hormones listed in EPA Method 539 at the appropriate concentrations.

Visualizza le informazioni del prodotto

Acroleina

This product has a limited shelf life. We recommend that you order only the ampul quantity that meets your immediate needs.

NOTE: Store standards under frozen conditions (0 °C or colder). We recommend you store ampuls lying flat (horizontally) to prevent breakage. For best results, thaw the contents of the ampul fully and shake the ampul well before opening and using the solution.

Visualizza le informazioni del prodotto

Standard nazionale 8330 (1,4-dinitrobenzene)

To ensure the highest quality explosives standards, Restek chemists carefully purify or synthesize all of the compounds listed in EPA Method 8330.

Visualizza le informazioni del prodotto

Composti isocianati singoli

ASTM D5836 and OSHA 42 are test methods for determining 2,4-toluene diisocyanate (2,4-TDI) and 2,6-TDI in the workplace atmosphere. OSHA 47 is for 4,4'-methylenediphenyl isocyanate (4,4'-MDI) in indoor air, and NIOSH Method 5522 is for 2,4-TDI; 2,6-TDI; 4,4'-MDI; and 1,6-hexamethylene diisocyanate (1,6-HDI) in air. Restek offers the 1,-(2-pyridyl)piperzine (1-2pp) derivative.

Visualizza le informazioni del prodotto

Soluzioni di toxafene

  • Toxaphene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Miscela standard di n-alcani per test prestazioni di sistema (16 componenti)

  • For GC analysis of total petroleum hydrocarbons (TPH) in water.
  • Environmentally safer than previous methods.
  • Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil.

Visualizza le informazioni del prodotto

Soluzione madre miscela standard (2 componenti)

  • For GC analysis of total petroleum hydrocarbons (TPH) in water.
  • Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil.

Visualizza le informazioni del prodotto

Kit pesticidi lista Ag 1 Minnesota

Contains 1 mL each of these mixtures.
32406: Minnesota Ag List Pesticides Mix A
32407: Minnesota Ag List Pesticides Mix B

Visualizza le informazioni del prodotto

Miscela standard di controllo qualità (2 componenti)

  • For GC analysis of total petroleum hydrocarbons (TPH) in water.
  • Environmentally safer than previous methods.
  • Calibration standard available as diesel #2/motor oil and diesel #2/mineral oil.

Visualizza le informazioni del prodotto

Miscela standard di controllo qualità, rivista (2 componenti)

  • Updated reference materials for GC analysis of TPH in water.
  • Determination of hydrocarbon oil index—applicable to drinking, surface, waste, and treated water.

Visualizza le informazioni del prodotto

C50 in toluene (n-pentacontano)

  • Meets CCME 2001 Petroleum Hydrocarbons in Soil MethodTier 1.
  • Primary reference calibration standards for quantification of four fractions.

Visualizza le informazioni del prodotto

Miscela di calibrazione CCME PHC (3 componenti)

  • Meets CCME 2001 Petroleum Hydrocarbons in Soil MethodTier 1.
  • Primary reference calibration standards for quantification of four fractions.

Visualizza le informazioni del prodotto

Standard interno tetrapentilstagno

Complete data pack available for audit compliance.

Visualizza le informazioni del prodotto

Surrogato cloruro di tripentilstagno

Complete data pack available for audit compliance.

Visualizza le informazioni del prodotto

Kit gasolio esposto ad agenti atmosferici 2

Contains 1 mL each of these mixtures.
31233: Diesel Fuel #2 Standard
31234: Diesel Fuel #2 Standard: 25% Weathered
31235: Diesel Fuel #2 Standard: 50% Weathered
31236: Diesel Fuel #2 Standard: 75% Weathered

Visualizza le informazioni del prodotto

Kit cherosene esposto ad agenti atmosferici

Contains 1 mL each of these mixtures.
31229: Kerosene Standard
31230: Kerosene Standard: 25% Weathered
31231: Kerosene Standard: 50% Weathered
31232: Kerosene Standard: 75% Weathered

Visualizza le informazioni del prodotto

Kit #2 benzina esposta ad agenti atmosferici

Contains 1 mL each of these mixtures.
30096: Unleaded Gasoline Standard
30097: Unleaded Gasoline Standard: 25% Weathered
30098: Unleaded Gasoline Standard: 50% Weathered
30099: Unleaded Gasoline Standard: 75% Weathered
30436: Unleaded Gasoline Standard: 99% Weathered

Visualizza le informazioni del prodotto

Acquaragia

There are four general types of mineral spirits, classified according to boiling point range (BPR):
  • Type I (Stoddard solvent), BPR 149–182 °C
  • Type II (high flash point), BPR 177–196 °C
  • Type III (odorless), BPR 149–196 °C
  • Type IV (low dry point), BPR 149–174 °C

    This standard is manufactured using the Type 1 mineral spirit.

    Note: Cat.#s 31260 and 31261 are produced with CAS# 64475-85-0, a Type 1 Mineral Spirit containing the proper ratio of n-alkanes (higher proportion) and isoparaffins/cycloalkanes (lower proportion). Lots produced prior to March 2017 contained CAS# 8030-30-6, a C10-C13 isoparaffins odorless Mineral Spirit with >98% isoparaffins (branched alkanes/aromatics) and minimal n-alkanes.

Visualizza le informazioni del prodotto

Gasolio N. 2 (accelerante ASTM di classe 5)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Visualizza le informazioni del prodotto

Cherosene (accelerante ASTM di classe 4)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Visualizza le informazioni del prodotto

Benzina senza piombo (accelerante ASTM di classe 2)

Prepared from a single source (one refinery) product. The weathered materials indicate the percent weight loss from the original material.

Visualizza le informazioni del prodotto

MA VPH - Miscela aggiunta in matrice cpn surrogato rev. 1.1 (luglio 2004) (16 componenti)

  • For current Massachusetts VPH method: surrogate included.
  • Matrix spike mix at 50µg/mL, per updated method.

Visualizza le informazioni del prodotto

Standard VPH con surrogato rev. 1.1 (luglio 2004) MA (16 componenti)

  • Standard for current Massachusetts VPH method: surrogate included.
  • More analyses per ampulstandard with surrogate is 10,000µg/mL.

Visualizza le informazioni del prodotto

Standard CA WIP VOA (11 componenti)

For monitoring samples suspected of gasoline contamination, Los Angeles County requires laboratories to calibrate and report these compounds.

Visualizza le informazioni del prodotto

Aromatici certificati in benzina (16 componenti)

  • Confirm unleaded gasoline TPH, BTEX, and aromatics in a single analysis.
  • Certificate of Analysis includes concentration of TPH, and certified concentrations of BTEX and individual aromatics.
  • Complete data pack available.

Visualizza le informazioni del prodotto

Standard solvente di Stoddard

We offer this certified reference material for those who need to calibrate Stoddard solvent separately. This standard is dissolved in methanol for analysis by either direct injection or purge and trap.

Visualizza le informazioni del prodotto

Miscela deterioramento olio combustibile (4 componenti)

Subsurface degradation of fuel oil spills can be estimated by examining the ratios of C17/pristane and C18/phytane.1 To assist in identifying these four compounds from the complex fuel oil analysis, we offer a product that contains these compounds for retention time determination.

Visualizza le informazioni del prodotto

Standard gasolio N. 2

Prepared from a single-source (one-refinery) product.

Visualizza le informazioni del prodotto

Standard cherosene

Prepared from a single-source (one-refinery) product.

Visualizza le informazioni del prodotto

Standard benzina senza piombo

Prepared from a single-source (one-refinery) product.

Visualizza le informazioni del prodotto

Standard olio idraulico

  • For total petroleum hydrocarbon pattern recognition of hydraulic oil.
  • High concentration50,000 µg/mL in methylene chloride.

Visualizza le informazioni del prodotto

Standard olio di creosoto

Creosote oil is a coal tar derived distillate.

  • For total petroleum hydrocarbon pattern recognition of creosote oil.
  • High concentration50,000 µg/mL in methylene chloride.

Visualizza le informazioni del prodotto

Standard gas aviazione

100-octane, low-lead fuel used in piston-type aircraft.

Visualizza le informazioni del prodotto

Standard olio combustibile N. 6

A high-viscosity residual type of heavy fuel oil requiring preheating to 104–127 °C. This material is also known as residual fuel oil (RFO) or Bunker C.

Visualizza le informazioni del prodotto

Standard olio combustibile N. 4

Fuel oil #4 is typically used in limited applications in which the fuel cannot be preheated prior to burning. The fuel is a blend of distillate (fuel oil #2) and residual (fuel oil #6).

Visualizza le informazioni del prodotto

Standard composito olio motore usato

  • Prepared from an equal-volume blend from five gasoline-powered vehicles (belonging to Restek employees). After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Standard composito olio motore

  • Prepared from an equal-volume blend of 5W30, 10W30, 10W40, and 20W50 motor oils. After blending, a precisely weighed amount of the composite is added to a volumetric flask to produce the standard.
  • Motor oil standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Standard composito cherosene

  • Kerosene composite standards are comprised of three separate sources blended in equal portions.
  • Kerosene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Standard composito gasolio N. 2

  • Diesel Fuel composite standards are comprised of three separate sources blended in equal portions.
  • Diesel Fuel standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Standard composito benzina senza piombo

  • Unleaded gasoline composite standards are comprised of three separate sources each of 87, 89, and 93 octane blended in equal portions.
  • Gasoline standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    NOTE: BTEX content of catalog numbers 30081, 30205, and 30206 is not measured. Certified BTEX gasoline standards are available as catalog numbers 30237 and 30485.

Visualizza le informazioni del prodotto

Miscela marcatori tempo di ritnzione TNRCC 1005 (4 componenti)

  • Easily determine the retention time window for each boiling point range.
  • Prepared in n-pentane according to EPA requirements.

Visualizza le informazioni del prodotto

Kit PCB 3

  • Aroclor standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    1,000 μg/mL each in hexane, 1 mL/ampul
    32007: Aroclor 1221
    32008: Aroclor 1232
    32009: Aroclor 1242
    32010: Aroclor 1248
    32011: Aroclor 1254
    32039: Aroclor 1016/1260

Visualizza le informazioni del prodotto

Kit PCB 2

  • Aroclor standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    200 μg/mL each in isooctane, 1 mL/ampul
    32064: Aroclor 1016
    32065: Aroclor 1221
    32066: Aroclor 1232
    32067: Aroclor 1242
    32068: Aroclor 1248
    32069: Aroclor 1254
    32070: Aroclor 1260

Visualizza le informazioni del prodotto

Kit PCB 1

  • Aroclor standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    1,000 μg/mL each in hexane, 1 mL/ampul
    32006: Aroclor 1016
    32007: Aroclor 1221
    32008: Aroclor 1232
    32009: Aroclor 1242
    32010: Aroclor 1248
    32011: Aroclor 1254
    32012: Aroclor 1260

Visualizza le informazioni del prodotto

Miscela standard pesticidi B con surrogati (13 componenti)

Components of these products are at 16x the contract-required quantitation level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

Visualizza le informazioni del prodotto

Miscela standard pesticidi A con surrogati (11 componenti)

Components of these products are at 16x the contract-required quantitation level (CRQL) and can be used to prepare calibration mixes at 4x CRQL and at 1x CRQL by serial dilution.

Visualizza le informazioni del prodotto

Miscela di calibrazione GPC rivista (5 componenti)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

Visualizza le informazioni del prodotto

Miscela di calibrazione GPC CLP (5 componenti)

Qualitative mixture useful for determining GPC dump/collect times. The compounds are dissolved in methylene chloride at the concentrations listed.

Visualizza le informazioni del prodotto

Kit di calibrazione composti semivolatili 3 (con benzidina)

Contains 1 mL each of these mixtures.
31007: SV Calibration Mix #1 (anilines)
31008: SV Calibration Mix #2 (phenols)
31009: SV Calibration Mix #3 (base neutrals)
31010: SV Calibration Mix #4 (base neutrals)
31011: SV Calibration Mix #5 (PAHs)
31013: SV Calibration Mix #7 (dichlorobenzenes)
31030: 605 Benzidines Calibration Mix (benzidine & 3,3'-dichlorobenzidine)

Visualizza le informazioni del prodotto

L/C VOA - Campione di controllo di laboratorio 2 (cloruro di vinile)

We prepare the L/C VOA Lab Control Sample in two parts. Sample #1 contains all compounds except vinyl chloride, because this compound is extremely volatile and must be replaced frequently. Sample #2 contains vinyl chloride.

Visualizza le informazioni del prodotto

VOA Kit N. 3 CLP 04.1

Contains 1 mL each of these mixtures.
30006: VOA Calibration Mix #1 (ketones)
30042: 502.2 Calibration Mix #1 (gases)
30456: CLP 04.1 VOA CAL2000 MegaMix Standard

Visualizza le informazioni del prodotto

Miscela di calibrazione N. 2 8330 (7 componenti)

EPA Method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection.1 Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

Visualizza le informazioni del prodotto

Miscela di calibrazione N. 1 8330 (7 componenti)

EPA Method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection.1 Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

Visualizza le informazioni del prodotto

Surrogato 8330 (1,2-dinitrobenzene)

EPA Method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection.1 Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

Visualizza le informazioni del prodotto

Standard nazionale 8330 (3,4-Dinitrotoluene)

EPA Method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection.1 Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

Visualizza le informazioni del prodotto

Miscela formaldeide-DNPH

  • High concentration.
  • Acetonitrile solventsuitable for HPLC analyses.

Visualizza le informazioni del prodotto

Miscela di calibrazione aldeide-chetone-DNPH TO-11A (15 componenti)

  • Convenient 15µg/mL concentration, similar to the concentration of interest in most ambient air work.
  • Fast analysis Ultra C18 HPLC column separates 15 aldehydes/ketones in 16 minutes.

Visualizza le informazioni del prodotto

Kit di calibrazione (2.000 µg/ml) 8270

Contains 1 mL each of these mixtures.
31618: 8270 Calibration Mix #1
31619: 8270 Calibration Mix #2
31620: 8270 Calibration Mix #3
31621: 8270 Calibration Mix #4
31995: 8270 Calibration Mix #5, Revised
31996: 3-Methylcholanthrene Standard

Visualizza le informazioni del prodotto

Kit 8270/Appendice IX

Contains 1 mL each of these mixtures.
31850: 8270 MegaMix Standard
31834: 605 Benzidines Calibration Mix
32459: Appendix IX Mix #1, Revised (Methapyrilene is not included in this revised standard.)
32460: Methapyrilene Standard
31806: Appendix IX Mix #2

Visualizza le informazioni del prodotto

Miscela aggiunta per matrice acida (5 componenti)

  • Highest concentrations commercially available.
  • Reduces laboratory cost per sample extract.

Visualizza le informazioni del prodotto

Miscela aggiunta in matrice B/N (6 componenti)

  • Highest concentrations commercially available.
  • Reduces laboratory cost per sample extract.

Visualizza le informazioni del prodotto

Miscela surrogato acido (4/89 SOW) (3 componenti)

  • Highest concentrations commercially available.
  • Convenient 1 mL, 5 mL, and 10 mL package sizes.
  • Reduces laboratory cost per sample extract.

Visualizza le informazioni del prodotto

Miscela surrogato B/N (4/89 SOW) (3 componenti)

  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.
  • Convenient 1 mL, 5 mL, and 10 mL package sizes reduce cost per sample extract.

Visualizza le informazioni del prodotto

Miscela standard interno SV (6 componenti)

  • High purity for consistent results.
  • Free quality assurance data package available online.
  • Highest concentrations commercially available.

Visualizza le informazioni del prodotto

Kit composti organici volatili (2.000 µg/ml) 8260

Contains 1 mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30043: 502.2 Calibration Mix #2
30044: 502.2 Calibration Mix #3
30045: 502.2 Calibration Mix #4
30046: 502.2 Calibration Mix #5
30047: 502.2 Calibration Mix #6
30067: 4-bromofluorobenzene (2,500 µg/mL)
30073: 8260 Surrogate Mix (2,500 µg/mL)
30074: 8260 Internal Standard Mix (2,500 µg/mL)
30075: 8240/8260 System Performance Check Mix
30005: VOA Matrix Spike Mix (2,500 µg/mL)

Visualizza le informazioni del prodotto

Kit composti organici volatili (2.000 µg/ml) 8260A

Contains 1 mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30043: 502.2 Calibration Mix #2
30044: 502.2 Calibration Mix #3
30045: 502.2 Calibration Mix #4
30046: 502.2 Calibration Mix #5
30047: 502.2 Calibration Mix #6
30067: 4-bromofluorobenzene (2,500 µg/mL)
30240: 8260A Surrogate Mix (2,500 µg/mL)
30241: 8260A Internal Standard Mix (2,500 µg/mL)
30075: 8240/8260 System Performance Check Mix
30005: VOA Matrix Spike Mix (2,500 µg/mL)

Visualizza le informazioni del prodotto

Miscela acetato (rivista) 8260 (7 componenti)

  • Includes methyl acetate and n-amyl acetate.
  • Contains 7 acetates.

Visualizza le informazioni del prodotto

Cloroprene

A pure, quantitative chloroprene solution, specially stabilized in purge-and-trap grade methanol to allow dilutions for working standards in unmodified purge-and-trap methanol. The entire preparation procedure is performed under carefully monitored conditions to prevent any contamination or polymerization of the highly reactive, neat chloroprene.

Visualizza le informazioni del prodotto

Surrogati e standard interni 8140/8141

FPD Detector:
Internal Standard: none recommended
Surrogate: tributylphosphate (cat.# 32280) and triphenylphosphate (cat.# 32281)

Visualizza le informazioni del prodotto

Surrogati e standard interni 8140/8141

NPD Detector:
Internal Standard: 1-bromo-2-nitrobenzene (cat.# 32279)
Surrogate: 4-chloro-3-nitrobenzotrifluoride (cat.# 32282)

Visualizza le informazioni del prodotto

Miscela clordano TCLP

  • Chlordane standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Miscela toxafene TCLP

  • Toxaphene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Miscela di calibrazione 418.1 (3 componenti)

Method 418.1 is an infrared spectrophotometric method for determining Total Recoverable Petroleum Hydrocarbons (TRPH). Dilute this mixture 1:200 to make the stock mixture specified in section 6.5.2 of Method 418.1.

Visualizza le informazioni del prodotto

Clordano, soluzioni di toxafene

  • Chlordane and toxaphene standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Soluzioni di aroclor

  • Aroclor standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

Visualizza le informazioni del prodotto

Kit completo 624

Contains 1 mL each of these mixtures.
30020: 624 Calibration Mix #1
30021: 624 Calibration Mix #2
30022: 624 Calibration Mix #3
30023: 624 Internal Standard Mix
30243: 624 Surrogate Standard Mix

Visualizza le informazioni del prodotto

Kit 624

Contains 1 mL each of these mixtures.
30020: 624 Calibration Mix #1
30021: 624 Calibration Mix #2
30022: 624 Calibration Mix #3
30023: 624 Internal Standard Mix

Visualizza le informazioni del prodotto

Kit completo 608

  • Aroclor, toxaphene, and chlordane standards may exhibit lot-to-lot variation.
  • See the Documentation tab for chromatograms on certificates of recently produced lots and inquire about availability.

    Contains 1 mL each of these mixtures.
    32022: 608 Calibration Mix
    32006: Aroclor 1016
    32007: Aroclor 1221
    32008: Aroclor 1232
    32009: Aroclor 1242
    32010: Aroclor 1248
    32011: Aroclor 1254
    32012: Aroclor 1260
    32005: toxaphene
    32021: chlordane

Visualizza le informazioni del prodotto

Acroleina/Acrilonitrile (2 componenti)

This product has a limited shelf life. We recommend that you order only the ampul quantity that meets your immediate needs.

NOTE: Store standards under frozen conditions (0 °C or colder). We recommend you store ampuls lying flat (horizontally) to prevent breakage. For best results, thaw the contents of the ampul fully and shake the ampul well before opening and using the solution.

Visualizza le informazioni del prodotto

Standard odore acqua potabile (2 componenti)

  • Reference mix of the two most common odor-causing compounds.
  • Convenient concentration for purge-and-trap analysis: 100 µg/mL in methanol.

Visualizza le informazioni del prodotto

Standard interni e surrogati per metodo 552

Internal Standard: cat.# 31648
Surrogate for Method 552, 552.1: cat.# 31650
Surrogates for Method 552.2: cat.#'s 31653, 31655, 31656
Surrogate for Method 552.3: cat.# 31881

Visualizza le informazioni del prodotto

Miscela acido aloacetico N. 2 (9 componenti)

  • Meet Stage 1 requirements for US EPA Methods 552, 552.1 and 552.2.
  • Meet requirements for Stage 2 DBPR.
  • Prepared from purified neat reference materials for the highest quality.
  • Lot-to-lot consistency ensures analytical reproducibility.

Visualizza le informazioni del prodotto

Miscela estere metilico acido aloacetico N. 1 (6 componenti)

  • Meet Stage 1 requirements for US EPA Methods 552, 552.1 and 552.2.
  • Meet requirements for Stage 2 DBPR.
  • Prepared from purified neat reference materials for the highest quality.
  • Lot-to-lot consistency ensures analytical reproducibility.

Visualizza le informazioni del prodotto

Miscela acido aloacetico N. 1 (6 componenti)

  • Meet Stage 1 requirements for US EPA Methods 552, 552.1 and 552.2.
  • Meet requirements for Stage 2 DBPR.
  • Prepared from purified neat reference materials for the highest quality.
  • Lot-to-lot consistency ensures analytical reproducibility.

Visualizza le informazioni del prodotto

Miscela di calibrazione pesticidi a base di carbammato 531.2 (11 componenti)

  • Complete set of materials for N-methylcarbamoyloximes and N-methylcarbamates.
  • New mix satisfies latest update of EPA Method 531.2.
  • Formulated in acetonitrile for stability and convenience for LC analysis.

Visualizza le informazioni del prodotto

Miscela standard interno, EPA 528 (2 componenti)

  • Reference materials for U.S. EPA Method 528.
  • Fortification solution formulated based on MS sensitivity to each analyte.

Visualizza le informazioni del prodotto

Miscela di calibrazione fenolo, EPA 528 (12 componenti)

  • Reference materials for U.S. EPA Method 528.
  • Fortification solution formulated based on MS sensitivity to each analyte.

Visualizza le informazioni del prodotto

Standard surrogato 524.2 (2 componenti)

  • Separate mixes for surrogates and internal standard.
  • Fortification solution combines surrogates and internal standard.
  • Calibration mixes and all other quality control mixes also available.

Visualizza le informazioni del prodotto

Kit VOA N. 2 (2.000 µg/ml) 524 Rev. 4.0

Contains 1mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30431: 502.2 MegaMix
30300: 524 Calibration Mix #7A
30304: 524 Calibration Mix #7B
30203: 524 Calibration Mix #8
30201: 524 Surrogate/Internal Standard Mix

Visualizza le informazioni del prodotto

Kit composti organici volatili (2.000 µg/ml) 524 Rev. 4.0

Contains 1 mL each of these mixtures.
30201: 524 Internal Standard/Surrogate Mix
30042: 502.2 Calibration Mix #1
30043: 502.2 Calibration Mix #2
30044: 502.2 Calibration Mix #3
30045: 502.2 Calibration Mix #4
30046: 502.2 Calibration Mix #5
30047: 502.2 Calibration Mix #6
30300: 524 Calibration Mix #7A
30304: 524 Calibration Mix #7B
30203: 524 Calibration Mix #8

Visualizza le informazioni del prodotto

Kit miscela di calibrazione N. 7 524

Contains 1 mL each of these mixtures.
30300: 524 Calibration Mix #7A
30304: 524 Calibration Mix #7B

Visualizza le informazioni del prodotto

Miscela erbicidi n. 2

Forma derivatizzata

Miscela erbicidi n. 2

Forma di acido libero

Miscela di valutazione sistema pesticidi organoclorurati (2 componenti)

  • Designed for daily assessment of system performance.
  • Reveals active sites in the injection port and/or GC column.
  • Prepared in MTBElow expansion volume helps minimize backflash.

Visualizza le informazioni del prodotto

Kit pesticidi 508.1

Contains 1 mL each of these mixtures.
32045: 508 Performance Check Mix
32091: 508.1 Internal Standard Mix
32092: 508.1 Surrogate Mix
32093: 508.1 GC Degradation Check Mix
32094: 508.1 Calibration Mix #1
32095: 508.1 Calibration Mix #2
32096: 508.1 Calibration Mix #3

Visualizza le informazioni del prodotto

Kit di calibrazione VOA N. 1 (2.000 µg/ml) 502.2

Contains 1 mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30043: 502.2 Calibration Mix #2
30044: 502.2 Calibration Mix #3
30045: 502.2 Calibration Mix #4
30046: 502.2 Calibration Mix #5
30047: 502.2 Calibration Mix #6

Visualizza le informazioni del prodotto

Agente antischiuma per campioni per purge & trap

  • Efficiently controls foam; effective over a wide pH range.
  • No hazardous materials, no components that are target analytes.
  • Effective at less than 0.1% of sample volume.

Visualizza le informazioni del prodotto

Kit di calibrazione VOA N. 3 (200 µg) 502.2

Contains 1 mL each of these mixtures.
30439: 502.2 Calibration Mix #1
30432: 502.2 MegaMix Standard

Visualizza le informazioni del prodotto

Kit di calibrazione VOA N. 2 (2.000 µg/ml) 502.2

Contains 1 mL each of these mixtures.
30042: 502.2 Calibration Mix #1
30431: 502.2 MegaMix Standard

Visualizza le informazioni del prodotto

Kit N. 2 (2.000 µg/ml)DW-VOC

Contains 1 mL each of these mixtures.
30211: 501 Trihalomethane Mix
30219: DW-VOC Mix #1
30220: DW-VOC Mix #2
30235: DW-VOC Mix #3

Visualizza le informazioni del prodotto

Miscela Massachusetts APH (26 composti)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

Visualizza le informazioni del prodotto

Miscela di calibrazione Giappone (9 composti)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

Visualizza le informazioni del prodotto

Miscela gas BTEX (6 composti)

Our high-quality air monitoring gas calibration standards are provided by Spectra/Linde and Airgas (formerly Scott/Air Liquide gas)meeting lab requirements for two separate sources of calibration standards.

Note: Actual cylinder pressure may vary due to loss from quality testing procedure.

To view compatible regulators, select your standard below and see Restek Recommends.

Visualizza le informazioni del prodotto