Regolatori di Gas Ultrapuri

Products

Regolatori gas in ottone cromato a purezza ultraelevata bifase

con raccordi CGA

  • Oxidation-resistant, chrome-plated.
  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.
  • Most widely used regulator.
  • Less internal volume than stainless steel gas regulators.
  • Also available with international fittings.

Visualizza le informazioni del prodotto

Regolatori gas in acciaio inox a purezza ultraelevata bifase

con raccordi CGA

  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.
  • Also available with international fittings.

Visualizza le informazioni del prodotto

Regolatori gas in ottone cromato a purezza ultraelevata monofase

con raccordi CGA

  • Oxidation-resistant, chrome-plated.
  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.
  • Also available with international fittings.

Visualizza le informazioni del prodotto

Regolatori gas in acciaio inox a purezza ultraelevata monofase

con raccordi CGA

  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.
  • Also available with international fittings.

Visualizza le informazioni del prodotto

Regolatore gas in linea in ottone cromato a purezza ultraelevata

  • Oxidation-resistant, chrome-plated.
  • Use where you need to reduce the line pressure by 20 psig (138 kPa) or more.
  • Same purity protection as high-pressure cylinder regulators.

Visualizza le informazioni del prodotto

Regolatori Silcosteel (fase doppia e fase singola)

Applications:
  • CEM continuous emission monitoring.
  • Environmental stack and gas emission standards.
  • Low-level sulfur and mercury analysis.
  • Reactive or corrosive gases.
  • Off-shore platform systems.
  • Corrosive and salt water exposure.

    Outlet pressure: 0 to 150 psig
    Outlet gauge: 30" 0 to 200 psig
    Inlet gauge: 0 to 4000 psig
    Outlet assembly: diaphragm valve, 1/4" tube fitting

Visualizza le informazioni del prodotto

Regolatori gas in acciaio inox a purezza ultraelevata monofase

con raccordi internazionali

  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.
  • Also available with CGA fittings.

Visualizza le informazioni del prodotto

Regolatori gas in ottone cromato a purezza ultraelevata monofase

con raccordi internazionali

  • Oxidation-resistant, chrome-plated.
  • Use when there is secondary pressure regulation downstream.
  • Identical gas purity protection as with dual-stage gas regulators.
  • Also available with CGA fittings.

Visualizza le informazioni del prodotto

Regolatori gas in acciaio inox a purezza ultraelevata bifase

con raccordi internazionali

  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.
  • Also available with CGA fittings.

Visualizza le informazioni del prodotto

Regolatori gas in ottone cromato a purezza ultraelevata bifase

con raccordi internazionali

  • Oxidation-resistant, chrome-plated.
  • Most stable outlet pressure control.
  • Secondary pressure regulation not needed.
  • Most widely used regulator.
  • Less internal volume than stainless steel gas regulators.
  • Also available with CGA fittings.

Visualizza le informazioni del prodotto

Regolatore MINICYL

This compact general purpose regulator has many laboratory applications including air-drying glassware, sparging or evaporating solutions, and controlling pneumatic valves. It is constructed of lightweight aluminum with an elastomer diaphragm. Includes a 060 psig (0-414 kPa) gauge and either 1/8- or 1/4-inch tube fittings.

Visualizza le informazioni del prodotto

Stazione protocollo

The protocol station is designed for convenient wall mounting of high-purity gas regulators. Wall mounting provides ease of use, prevents gas regulator damage, and improves safety. Either chrome-plated brass or 316 stainless steel option is complete with a 3-foot, flexible, all-stainless-steel pigtail with armor casing. The CGA connection on the pigtail has an integral check valve in the gland to prevent contamination during cylinder changeout.

Visualizza le informazioni del prodotto

Sistema di commutazione automatica per gas non corrosivi (purezza critica)

High-purity automatic switchover systems provide a continuous supply of high-purity gas to the laboratory, process, or instrument to allow you to replace a depleted gas source without interruption in the gas supply. Continuous gas supply is achieved by setting the two regulators at slightly different pressures and discharging one side of the system at a time. These models include flexible, all-stainless-steel pigtails with armor casing. The CGA connection on each pigtail has a check valve in the gland to prevent contamination and minimize purging requirements.

Visualizza le informazioni del prodotto

Supporto cilindro, da banco

Prevent serious injuries! This holder is designed to prevent a free-standing gas cylinder from tipping over and injuring personnel. Stainless steel holder secures to the side of a workbench. Each mount secures a cylinder 412 inches in diameter.

Visualizza le informazioni del prodotto

Raccordi CGA

CGA-specified nuts and nipples with internal frit, 1/4-inch NPT nickel-plated brass.

Visualizza le informazioni del prodotto

Supporti cilindro, da parete

Prevent serious injuries! These holders are designed to prevent free-standing gas cylinders from tipping over and injuring personnel. The cast aluminum holder can be secured to a wall or the side of a work bench. Each mount will secure a cylinder 4-15 inches in diameter.

Visualizza le informazioni del prodotto

Dispositivo di arresto di esplosione idrogeno

  • Valve cuts off gas supply in the event of a flashback.
  • Can be reset and reused after flashback has occurred.
  • Meets safety requirements of BS6158, EN730, ISO 5175, AS 4603 and are UL Listed 23Y5.

Visualizza le informazioni del prodotto