Generatori di gas

Products

Generatori di idrogeno H2PEMPD Parker Balston

  • Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
  • Maintenance-free palladium purifier removes oxygen to <0.01 ppm and moisture to <1.0 ppm.
  • Produces continuous supply of 99.99999+% pure hydrogen gas.
  • Does not require downstream gas filters.
  • Maximum outlet pressures of 100 or 175 psig (690 or 1,200 kPa).
  • Automatic safety feature shuts the generator down if a hydrogen leak is detected.
  • Compact unit, requires only one square foot of bench space.
  • Warranty: one year from date of purchase on system and three years from date of purchase on cell life.

Visualizza le informazioni del prodotto

Generatori di azoto Parker Balston per LC-MS

  • Turn compressed air into ultra-pure nitrogen (up to 99.5%).
  • Flows from 1 to 44 L/min.
  • Models N2-04, N2-14, N2-22, and N2-35 require no electricity.
  • Safe, reliable, low maintenance.
  • Maintenance kits include replacement filters.
  • 12-month warranty from date of purchase.

Visualizza le informazioni del prodotto

Generatori di idrogeno PEM Parker Balston

  • Proton exchange membrane (PEM) cell eliminates the need for liquid electrolytes.
  • Reliably generate 99.9999% pure hydrogenfor better chromatography.
  • Eliminates high-pressure cylindersgreater convenience and improved lab safety.
  • Compact unit, requiring only one square foot of bench space.
  • Quick and easy to service and maintain; unique display lighting changes color for easy status checks and water level indication.
  • Comes with a set of universal power adapters for U.S., European, and Asian plug types.
  • Automatic safety feature shuts the generator down if a hydrogen leak is detected.
  • Warranty: one year from date of purchase on system and two years from date of purchase on cell life.

Visualizza le informazioni del prodotto

Stazioni gas modello FID-1000 e FID-2500 Parker Balston

  • Single unit produces UHP zero air from house compressed air and 99.9995% pure hydrogen from deionized water.
  • Ideal for supplying up to 5-6 FIDs.
  • Eliminates inconvenient and dangerous gas cylinders.
  • Silent operation, minimal operator attention required.
  • 12-month warranty from date of purchase.

Visualizza le informazioni del prodotto

Generatori di azoto Parker Balston

  • Produces ultra-pure nitrogen (up to 99.9999%).
  • Requires only a compressed air source and 110 volt AC power.
  • Typical applications include GC carrier gas, make-up gas, and low-flow sample concentrators.
  • Maintenance kits include replacement filters.
  • 12-month warranty from date of purchase.

Visualizza le informazioni del prodotto

Generatori aria zero Parker Balston

  • Turn in-house compressed air into ultra-pure air (<0.1 ppm total hydrocarbons).
  • Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation.
  • Operate at 40–125 psi (276–862 kPa).
  • Typical payback is less than one year, based on cylinder costs.
  • Install easily and take up little bench space.*
  • Maintenance kits include a one-year supply of prefilters and final filter.

Visualizza le informazioni del prodotto

Sistema idrico DI Parker HydroGen Mate

  • Economical means of providing deionized water to hydrogen generators, or for other uses.
  • Quick and easy installation; minimal maintenance.
  • Removes organics, phosphates, chlorine, and essentially all ionizable constituents from your water supply.
  • Easy-fill dispensing gun.
  • Visual indication for cartridge changes.
  • 12-month warranty from date of purchase.

Visualizza le informazioni del prodotto