Filtrazione del campione

Products

Filtri Siringa con ingresso Luer Lock

  • L’attacco Luer lock offer una connessione a tenuta con le siringhe .
  • Ampia varietà di dimensioni, tipologie di membrane e porosità.
  • Identificabili con colori diversi.
  • Corpo in polipropilene.
  • Autoclavabili fino a 121°C per 15 minuti.
  • Risparmio garantito sulle grandi quantità

Visualizza le informazioni del prodotto

Standard Filter Vials Thomson SINGLE StEP

  • Recommended for samples containing less than 10% solid particulates.
  • Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers.
  • Minimize sample loss by eliminating multiple transfers.
  • Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.
  • Preslit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.
  • Rugged polypropylene vial houses insert with 450 μL loading capacity and low dead volume (120 μL).
  • Fit most standard 12 x 32 mm autosamplers, including UHPLC instruments.

Visualizza le informazioni del prodotto

Low Evaporation Filter Vials Thomson SINGLE StEP

  • Enhanced evaporation prevention technology ensures less than 0.4% evaporation over 24 hours.
  • Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers.
  • Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, or nylon.
  • Rugged polypropylene vial houses insert with 450 μL loading capacity and low dead volume (120 μL).
  • Fit most standard 12 x 32 mm autosamplers, including UHPLC instruments.

Visualizza le informazioni del prodotto

eXtreme Filter Vials Thomson SINGLE StEP

  • Provide multilayer filtration for viscous samples and samples containing up to 30% solid particulates.
  • Allow compounds to be separated from matrix, resulting in both higher signal-to-noise ratios and more differentiated peaks.
  • Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers.
  • Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.
  • Pre-slit PTFE/silicone caps help eliminate broken autosampler needles and cored septa.
  • Rugged polypropylene vial houses insert with 450 μL loading capacity and low dead volume (120 μL).
  • Fit most standard 12 x 32 mm autosamplers, including UHPLC instruments.

Visualizza le informazioni del prodotto

Nano Filter Vials Thomson SINGLE StEP

  • Ultra-low dead volume allows you to filter as little as 10 μL of sample and still obtain enough filtrate to make a 2 μL injection.
  • Easy-to-use vials offer fast sample filtration and require only a squeeze of your fingers.
  • Color-coded caps allow easy identification of 0.2 μm or 0.45 μm membranes in PVDF, PTFE, PES, or nylon.
  • Available with either standard or pre-slit PTFE/silicone caps. Standard caps minimize evaporation and pre-slit caps help eliminate broken autosampler needles and cored septa.
  • Rugged polypropylene vial houses insert with 250 μL loading capacity and extremely low dead volume (8 μL).
  • Fit most standard 12 x 32 mm autosamplers, including UHPLC instruments.

Visualizza le informazioni del prodotto