delim
delim
delim
Manutenzione colonne capillari

Manutenzione colonne capillari

Products

Taglia colonne in ceramica

Four straight scoring edges for cutting fused silica tubing and four serrated edges for cutting MXT metal capillary columns.

Visualizza le informazioni del prodotto

Taglia colonne con impugnatura

  • Ceramic wafer is straight-edged for cutting fused silica tubing cleanly.
  • Unique, ergonomic handle is made of soft, comfortable rubber.

Visualizza le informazioni del prodotto

Tappi colonna capillare

  • Attach to the column in seconds to form an airtight seal.
  • Increase column lifetimeprevent moisture and air from entering the column during storage.
  • Two styles to choose from: glass or silicone material.
  • Glass caps are color-coded for identifying detector and injector ends.
  • Not recommended for reuse.

Visualizza le informazioni del prodotto

Filo alta temperatura

Use to restring capillary columns, attach column connectors to column cages, or hold the column in the GC oven. Capable of withstanding temperatures to 400 °C.

Visualizza le informazioni del prodotto

Lente d'ingrandimento da taschino

  • Small and easy to handle.
  • 10x magnification makes it easy to see the column end to verify a square cut.

Visualizza le informazioni del prodotto

Pinzette a molla con blocco laterale e righello in acciaio compatto di 15 cm

  • “Lock” capillary columns to the correct insertion distance recommended by the instrument manufacturer during installation.
  • Useful for many laboratory tasks.

Visualizza le informazioni del prodotto

Gancio colonne

per GC Agilent 7890, 6890, 5890 e 5880A

Kit cilindro metano

Per l'ottimizzazione della velocità lineare

Setting the column flow rate by injecting methane and optimizing linear velocity is a preferred method for establishing reproducible retention times (ASTM Method E1510-93). The kit includes an Airgas (formerly Scott/Air Liquide gas) 14 cylinder containing 1% methane in helium, a MINICYL regulator, a syringe adaptor, and a package of twenty-five septa for the adaptor.

Visualizza le informazioni del prodotto

Taglierino colonna GC capillare Shortix

  • Consistently make precise, clean, square cuts with a diamond blade.
  • Built-in magnifier to verify square cut.
  • Use with 0.25 mm ID to 0.53 mm ID tubing (0.78 mm OD maximum).

    Note: For fused silica tubing only.

Visualizza le informazioni del prodotto

Kit serbatoio di lavaggio colonna capillare

Restore the performance of bonded-phase capillary columns by dissolving and removing soluble, nonvolatile residue, using this reservoir kit. The 50 ml rinsing reservoir is equipped with 1/4-inch inlet and outlet connections and includes a built-in fritted disk to prevent particulate matter from contaminating the column. The kit includes reservoir, pressure regulator, fittings, ferrules, and tubing. Reservoir also available separately.

Visualizza le informazioni del prodotto

Lime ad ago MXT

Multi-purpose files especially useful for cutting Siltek treated stainless steel columns.

Visualizza le informazioni del prodotto

Incisore di zaffiro

  • Cuts fused silica tubing.
  • Produces a clean, square cut.

Visualizza le informazioni del prodotto